Repair Main Gas Valve Bldg 100

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
W50S6T26QA018
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
California 93727, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The 144th Fighter Wing is soliciting repair and replacement of the main gas valve at Building 100, Fresno Air National Guard Base, with proposals due June 11, 2026. The procurement is a 100% women-owned small business (WOSB) set-aside, restricting competition to that category.

Place of performance is Fresno, California (5323 E. McKinley Avenue, Building 125). The work involves reconfiguring approximately 30 linear feet of existing natural gas piping, removing and replacing the main regulator and associated valves, installing a minimum of three cut-off valves, pressure and leak testing all systems, and finishing new piping with safety yellow paint per UFC and industry standards. All work must comply with UFC 3-420-01, UFC 3-430-05, Uniform Plumbing Code, NFPA 54, ASME B31.3, ASME B31.8, and OSHA requirements. Contractors must hold a current California C-36 license or equivalent credential demonstrating competency in plumbing and gas system work. The NAICS code is 238220, Plumbing, Heating, and Air-Conditioning Contractors, with a small business size standard of $19 million.

This is a Firm Fixed Price award without post-award negotiations; the 144th FW encourages quoters to submit their most advantageous pricing in initial response. The contract value is $19 million. Period of performance is July 6 through August 7, 2026, with work hours 7:00 a.m. to 4:30 p.m. Monday through Friday, excluding weekends and federal holidays. Maximum contract duration is 30 calendar days.

All quoters must hold a CAGE code and SAM registration. Submissions must include a written work procedure not exceeding two pages, subcontractor acknowledgments with business names and locations, and proof of qualifications. A site visit is available June 2, 2026 at 0830 PDT; attendees must complete DBIDS pre-enrollment and base access clearance 5-10 business days prior. Foreign nationals require 45-90 business days for background review. Prevailing wage rates apply per Davis-Bacon Act requirements. Contracting officer is Justin Scales, 559-545-5129, justin.scales.1@us.af.mil.

Notice text

2 versions

Update #2 · Latest ·

The 144 FW is requesting repair/replacement of the main gas valve at building 100. Request for Quote (RFQ) details are provided on the attached solicitation. The 144 FW intends to award a Firm Fixed Price (FFP) contract without negotiations, so offerors are highly encouraged to quote their most advantageous pricing in their initial response. 

This requirement is being solicited as 100% small business set-aside. The NAICS code for this acquisition is 238220 and the Small Business size standard is $19M. All prospective quoters must have a Commercial and Government Entity (CAGE) code and be registered with System for Award Management (SAM) at http://www.sam.gov. Offerors shall respond to this RFQ via email. Quotes shall be submitted electronically to the following email addresses: jarrod.sanchez@us.af.mil; justin.scales.1@us.af.mil

Any quote, modification, or revision of a quote received after the exact time specified for receipt of quotes is late and will not be considered. Review the RFQ solicitation instructions for quote submission criteria at section- Addendum to 52.212-1, Instructions to Offerors - Commercial Products and Commercial Services.

Site Visit Notice:

A site visit will be available on 2 June 2026 at 0830 PDT. Approved participates shall meet at the West gate near 5323 E McKinley Ave, Fresno CA 93727. All potential attendees must complete DBIDS pre-enrollment and be listed on the base access form, section CONTRACTOR/VENDOR/VISITOR INFORMATION. https://dbids-global-enroll.dmdc.mil/preenrollui/#/landing-page

A background review will be performed and only participants that have been cleared by security will be allowed to attend the site visit. Complete the base access form, consisting of attendee names, citizenship, and DBIDS code (6-digit code accompanied with QR code). The base access form must be provided 5-10 business days before the site visit. A foreign national requires 45-90 business days to review background. If a confirmation has not been provided contact our office prior to the site visit to verify base access.

Update 1: Images of gas pipes have been added.

Update #1 ·

The 144 FW is requesting repair/replacement of the main gas valve at building 100. Request for Quote (RFQ) details are provided on the attached solicitation. The 144 FW intends to award a Firm Fixed Price (FFP) contract without negotiations, so offerors are highly encouraged to quote their most advantageous pricing in their initial response. 

This requirement is being solicited as 100% small business set-aside. The NAICS code for this acquisition is 238220 and the Small Business size standard is $19M. All prospective quoters must have a Commercial and Government Entity (CAGE) code and be registered with System for Award Management (SAM) at http://www.sam.gov. Offerors shall respond to this RFQ via email. Quotes shall be submitted electronically to the following email addresses: jarrod.sanchez@us.af.mil; justin.scales.1@us.af.mil

Any quote, modification, or revision of a quote received after the exact time specified for receipt of quotes is late and will not be considered. Review the RFQ solicitation instructions for quote submission criteria at section- Addendum to 52.212-1, Instructions to Offerors - Commercial Products and Commercial Services.

Site Visit Notice:

A site visit will be available on 2 June 2026 at 0830 PDT. Approved participates shall meet at the West gate near 5323 E McKinley Ave, Fresno CA 93727. All potential attendees must complete DBIDS pre-enrollment and be listed on the base access form, section CONTRACTOR/VENDOR/VISITOR INFORMATION. https://dbids-global-enroll.dmdc.mil/preenrollui/#/landing-page

A background review will be performed and only participants that have been cleared by security will be allowed to attend the site visit. Complete the base access form, consisting of attendee names, citizenship, and DBIDS code (6-digit code accompanied with QR code). The base access form must be provided 5-10 business days before the site visit. A foreign national requires 45-90 business days to review background. If a confirmation has not been provided contact our office prior to the site visit to verify base access.

Files

Notice history

Notice Type Posted
Repair Main Gas Valve Bldg 100 Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Replace HVAC Rooftop Units at Building 2275 March Air Reserve Base, California 92518, United States · NAICS 238220 Army National Guard No set-aside
Mather Fueling System Repairs Mather, California 95655, United States · NAICS 237120 ENDIST Omaha Total Small Business
Replacement of 10 Ton HVAC Unit, Bldg. 11, PR ANG Carolina, Puerto Rico 00979, United States · NAICS 238220 Army National Guard Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity