PRQE 222193, Replace UPS and Electrical Upgrade Bldg. ’s. , 35 (McConnell AFB, KS 67221) & 5010 (Smoky Hill Bomb Range Salina, KS 67401)
Closed Solicitation Posted
- Solicitation number
- W50S7X-23-B-0002
- Agency
-
Army National Guard
Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- McConnell AFB, Kansas 67221, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks offers to replace uninterruptible power supply systems and perform associated electrical upgrades at Building 35 located at McConnell Air Force Base in Kansas and Building 5010 located at Smoky Hill Bomb Range in Salina, Kansas. Offerors must remove and replace existing UPS units and install new supply circuits, output circuits, panels, conduit, wiring and fittings. All existing electrical loads must be relocated to new output panels. Demolition of old input and output components is required. Offerors must attend a pre-proposal site visit by May 16, 2023 and submit offers by June 13, 2023. Award will be a firm-fixed-price contract to the responsible small business offering the best value based on technical approach and price.
This opportunity is set aside for total small businesses. The primary NAICS code is 238210 and PSC code R499. Three offers were received ranging from $300,000 to $416,652.02. The work must be completed within 90 days of notice to proceed and includes replacing UPS units rated at 30kW and 20kW to provide a minimum four-hour run time. The place of performance is Building 35 at McConnell Air Force Base, Wichita, Kansas and Building 5010 at Smoky Hill Bomb Range, Salina, Kansas.
Notice text
2 versions
Update #2 · Latest ·
In Bldg 35 and Bldg 5010 remove and replace the existing Uninterruptable Power Supply (UPS). Electrical work will be required as part of the replacement. In both buildings there will need to be installed a new supply circuit to the UPS. This circuit will require a new breaker, conduit, wiring and associated fittings. The existing supply panel will accomodate the new circuit in both cases. On the output of the UPSs a new circuit (conduit, wiring and associated fittings) will be required and will connect the UPS to a new Output power panel. All existing loads on the existing panel will need to be relocated to the new output panel. Demolition of the old input circuit and the output circuit and output panel are required as part of this project. For more details refer to the Statement of Work and associated drawings.
4 JUNE 2023: Acknowledge Solicitation Amendment W50S7X-23-B-0002-0001, dated 3 June 2023 For Wage Determination Update and see current attached: KS20230057 (Sedgwick) Mod 05 6-2-2023, & KS20230045 (Saline) Mod 04 5-26-2023.
Update #1 ·
In Bldg 35 and Bldg 5010 remove and replace the existing Uninterruptable Power Supply (UPS). Electrical work will be required as part of the replacement. In both buildings there will need to be installed a new supply circuit to the UPS. This circuit will require a new breaker, conduit, wiring and associated fittings. The existing supply panel will accomodate the new circuit in both cases. On the output of the UPSs a new circuit (conduit, wiring and associated fittings) will be required and will connect the UPS to a new Output power panel. All existing loads on the existing panel will need to be relocated to the new output panel. Demolition of the old input circuit and the output circuit and output panel are required as part of this project. For more details refer to the Statement of Work and associated drawings.
Files
Show all 12
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| PRQE 222193, Replace UPS and Electrical Upgrade Bldg. ’s. , 35 (McConnell AFB, KS 67221) & 5010 (Smoky Hill Bomb Range Salina, KS 67401) | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Switchgear Transformer Replacement | Army National Guard | Total Small Business | |
| FTG247 Replace UPS at IDT1, Fort Greely, Alaska | ENDIST Alaska | Total Small Business | |
| Repair Electrical Systems | AFLCMC Wright Patterson AFB | No set-aside | |
| 6135--Uninterrupted Power Supply (UPS) Batteries | Veterans Integrated Service Network 4 | Woman-Owned Small Business | |
| 6135--UPS Battery Replacement | Veterans Integrated Service Network 22 | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity