Project 534-23-907 Renovate Chiller Area

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24724R0039
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
541330 Engineering Services
Place of performance
Charleston SC 29401

Notice details come from SAM.gov. Updated .

About this opportunity

This Pre-solicitation Notice seeks proposals from architecture and engineering firms to provide design services for the renovation of a 3,119 square foot chiller area at the Ralph H. Johnson VA Medical Center in Charleston, South Carolina. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 7 will evaluate proposals using SF330 forms submitted by the January 22, 2024 deadline. The scope of work involves adding an eight-workstation office space, reworking two other areas to create a new shop space and storage space, and managing the project through construction administration services.

The contract is set aside exclusively for service-disabled veteran-owned small businesses as defined by NAICS 541330 for Engineering Services. The estimated value is between $500,000 and $1,000,000 to be completed within 279 calendar days following award. Solicitation number 36C24724R0039 for project number 534-23-907 will procure these architectural and engineering design services for the specified chiller area renovation by the anticipated September 30, 2024 award date.

Notice text

This Pre-solicitation Notice is NOT A REQUEST FOR PROPOSAL. ALL INFORMATION NEEDED TO SUBMIT SF330 DOCUMENTS ARE CONTAINED HEREIN.  NO ADDITIONAL SOLICITATION PACKAGE OR TECHNICAL INFORMATION WILL BE ISSUED. 

Project:  534-23-907 A/E Design for Renovate Chiller Area

Work Location:  Ralph H. Johnson VA Medical Center, Charleston, SC

Estimated/Target Completion Period:  279 Calendar days after Award.

Construction Magnitude: Between $500,000 and $1,000,000.

NAICS: 541330 - Engineering Services

Small Business Standard: $25.5 million

Set-Aside: 100% Service-Disabled Veteran-Owned Small Business (SDVOSB)

Site Visits will not be arranged during this phase.

The anticipated award date of the proposed A-E Contract is on or before September 30, 2024. 

SF 330 Date of Receipt/Due Date:  Interested firms having the capabilities to perform this work must submit one (1) electronic SF 330 and attachments (if any) no later than (NLT) 12:00 PM (EST) January 22, 2024.

PROJECT OVERVIEW:

The purpose of this design project is to renovate 3,119 SF by adding an office space with 8 workstations, and rework two other areas to provide a new shop space and a new storage space.  Much of the old equipment in this old chiller room has been removed allowing for open/free space to provide much needed area for cubicles for MORR Office personnel and shop equipment. This additional shop space will be an area to service Ice Machines, Refrigerators, Freezers, etc. This storage space will be primarily for components necessary to keep the main corridors in good working order.  This new MORR office will increase efficiency by lending additional support to shop personnel for work orders, outages, projects, etc. Work Order Completion Percentage will improve as a result of adding shop space and relocating support personnel to the area.

Files

File Type Posted
04-534-23-907 AE SOW_01.docx DOCX document
534-23-907 PPQ.docx DOCX document
36C24724R0039.docx DOCX document

Notice history

Notice Type Posted
C1DA--Project 534-23-907 Renovate Chiller Area (VA-24-00010747) Award Award Notice
This notice Latest pre-solicitation Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
CON | Z1DA | replace or chillers | 580-23-105 | solicitation Houston, Texas 77030, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Replace B28 AHU 1, 4, 18, 9A, 9B, OR Chiller Amarillo, Texas 79106, United States · NAICS 238220 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business
C1DA--544-27-110 | Update Facility Masterplan Architect and Engineering Department of Veterans Affairs Columbia VA Health Care System Columbia, South Carolina 29209, United States · NAICS 541330 Veterans Integrated Service Network 7 Service-Disabled Veteran-Owned Small Business
C1DA--VISN 1 - INDEFINITE DELIVERY INDEFINITE QUANTITY ARCHITECT CONTRACT (Legacy VISN 5) (Legacy) Visn 5 - Washington Dc (Legacy) Visn 5 -Vamhcs (Maryland) · NAICS 541330 Veterans Integrated Service Network 5 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors