(PROJ: 573-19-616) BB Correct Electrical Deficiencies (3-Year Test)

Closed Special Notice Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24823R0042
Agency
Veterans Integrated Service Network 8 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Y1DA Construction Of Hospitals And Infirmaries
Place of performance
Gainesville, Florida 32608, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This Special Notice from the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 8 seeks proposals to address electrical deficiencies identified through a three-year testing program at various federal facilities. Project number 573-19-616 involves correcting deficiencies such as breaker replacement, transformer oil filtration, and installation of approved panel covers.

The objective is to solicit contractor proposals due by December 5, 2022 at 1:00 PM to perform corrective work on a test basis over three years. The opportunity is set aside for Service-Disabled Veteran-Owned Small Businesses. Responses are requested for requests for information numbered 36C24823R0042 related to replacing breakers and other corrective actions identified in the deficiency report. Technical specifications and the responses to contractor questions provide additional details to inform proposals for the electrical work.

Notice text

3 versions

Update #3 · Latest ·

RESPONSES TO RFIs 36C24823R0042 - 573-19-616 - Correct Electrical Deficiencies (3-YearTest)

Proposals due on 12/13/2022 at 1:00 PM

Here is the information for the breakers requested.

EUL-2-BA – A026-1 – Main Breaker – Square D QO, 200A, 120/240V, double pole breaker. Panel is slated to be replaced with project 573-19-614.

RSPA – B047-1 – crt 41 - Square D QOB, 20A, 120V, 22kA, single pole breaker.

UL-2-4A (SEC 2) – A412A-1 – crts 25, 27 - ITE EF1-B020 GV-1, 20A, 120V, single pole breakers.

CLL-3-1D – D166-1 – crt 4 - ITE EF1-B020 GV-1, 20A, 120V, single pole breaker.

CC8 – C080B-1 – crt 16, 18, 20 – Square D QOB, 30A, 10kA, three pole breaker.

CUL-D101-BD – D101-1 – Panel no longer exists.

AECL1B – G163-1 – crt 5, 7, 9 -  Square D Iline, FCB34090, 90A, 277/480V, 65kA, Three pole breaker

L13B – J102-1 – crt 97, 99, 101 – Square D QOB, 40A, 120/208V, 22kA, three pole breaker.

H42 – J451-1 – crt 42 – Square D NF, 20A, 277/480V, single pole breaker.

Let me know if you need additional information.

Update #2 ·

RESPONSES TO RFIs 36C24823R0042 - 573-19-616 - Correct Electrical Deficiencies (3-YearTest)

Proposals due on 12/09/2022 at 1:00 PM

Update #1 ·

RESPONSES TO RFIs 36C24823R0042 - 573-19-616 - Correct Electrical Deficiencies (3-YearTest)

Proposals due on 12/05/2022 at 1:00 PM

Attachments

Files attached to this notice, newest first
File Type Posted
RFI 7 Breaker List from 3 Year Test.pdf PDF
SITE VISIT SIGN IN SHEET.pdf PDF
EF-1_Updated with EXP Motor.pdf PDF
RESPONSES - RFIs 36C24823R0042.pdf PDF
SF30 - RFI -36C24823R0042 0001_1.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Y1DA-- FY23: NRM Tier 1 (PROJ: 573-19-616) BB Correct Electrical Deficiencies (3-Year Test) Award Award Notice
(PROJ: 573-19-616) BB Correct Electrical Deficiencies (3-Year Test) This notice · Latest special notice Special Notice
(PROJ: 573-19-616) BB Correct Electrical Deficiencies (3-Year Test) Original Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity