Paragraph 1:
The Department of the Army Corps of Engineers Engineering District Wilmington is seeking proposals to repair Building E-1650 at Fort Liberty in North Carolina. The work includes upgrading the fire detection and suppression system, interior layout, and sensitive and secure facilities measures. A portion of the building needs to meet the requirements of ICD 705 and AR 380.5 for secret open storage. The existing building envelope will also receive improved insulation and moisture protection. The site work consists of replacement of concrete pavement, sidewalks, a new fire water main, replacement of hot and chilled water mains, electric, and other site features. Proposals are due by September 19, 2024 at 1 PM.
Paragraph 2:
This opportunity is set aside for small businesses. The building is approximately 21,462 square feet, with a total disturbed area of 36,435 square feet (0.84 acres). No potential incumbents or current contractors are named. The contract value is not specified, but the detailed scope of work and scale of the project suggests it may be a significant dollar amount. The place of performance is Fort Liberty, North Carolina.
Notice text
PN MB-00009-20, Repair Building E-1650, at Fort Liberty, North CarolinaProvide all personnel, management, tools, materials, supervision, general and specialized equipment, and services necessary to repair of office space administration of building E1650 located on Fort Liberty, NC and incidental related work. The building renovation includes upgraded fire detection and suppression system, interior layout, and sensitive and secure facilities measures. A portion of the building is designed to meet the requirements of ICD 705 and AR 380.5 Secret Open Storage requirements, which includes the construction of STC rated assemblies and penetrations, as well as at interior compartmentalized areas. The existing building envelope (exterior walls and roof) will receive improved insulation and moisture protection to increase energy efficiency. The site work consists of replacement of concrete pavement, sidewalks, a new fire water main, replacement of hot and chilled water mains, electric, and other site features and appurtenances. The building is approximately 21,462 SF. The total disturbed area in the limits of construction is 36,435 SF (0.84 acres)
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| MB-00009-20 Repair Bldg E-1650, Fort Liberty | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| PN 110205 - SOS Hangar Renovation - Progressive-Design-Build OT | ENDIST Wilmington | No set-aside | |
| Design-Build Maintenance and Repair Army Reserve (MRAR) of Equipment Concentration Site (ECS), B-56767, at North Fort Hood, TX | ENDIST Louisville | Total Small Business | |
| Renovate Building 286 & Building 497, Demolish Building 298 | Naval Facilities Engineering Command | Total Small Business | |
| WWYK260004 - repair structural integrity, B1134, post 34 & north wall | Air Force Sustainment Center | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity