The Department of the Interior Bureau of Reclamation is issuing a pre-solicitation notice for Personal Identity Verification (PIV) access system repairs at buildings 67 and 56 of the Denver Federal Center in Denver, Colorado. The contractor must be credentialed and qualified to work on the Velocity software and products required for this project. Key requirements include replacing malfunctioning MX8 motherboards with new MX8s and SNIB3s, replacing standby batteries, and performing programming, configuration, and testing of the accesses. The contractor will also need to troubleshoot and repair issues with the magnet release and low-power panels. The work must be completed during normal business hours, Monday through Friday. The NAICS code for this opportunity is 561621 - Security Systems Services.
This pre-solicitation notice does not have any set-aside designations. The potential value of the contract is not specified. The related NAICS code of 561621 and PSC code of N075-P indicate that this is likely a smaller services contract. The posting date is October 14, 2024, and proposals are due by October 25, 2024.
Notice text
Personal Identity Verification (PIV) Access System repairs at buildings 67 and 56, Denver Federal Center, Denver Colorado, 80225. The contractor must be credentialed and qualified to work on Velocity software and products (Velocity
environment).All installed replacement parts must be new and must be compatible with the Velocity environment: New MX8 mother board with SNIB3, adapter bracket so that the MX8 mother board will mount inside the existing MX8 enclosure, EBIC5 long ribbon cable to connect SNIB3 to MX8 motherboard and new standby batteries. The contractor must replace the existing malfunctioning MX8s with a new MX8s and SNIB3s. The new equipment should be retrofitted into the current panel, as necessary. Standby batteries should be replaced. Additionally, the technician should perform programming, configuring, and testing of accesses. NAICS Code: 561621
Files
| File | Type | Posted |
|---|---|---|
| PIV_Access_System_Repairs_Scope_of_Work__26_July_2024_1.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| EC-ECAO Exterior Door Replacement | — | Total Small Business | |
| EC-ECAO Exterior Door Replacement | — | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity