PCR System- Ann Arbor

Closed Solicitation Posted

Solicitation number
36C25026Q0499
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Ann Arbor, Michigan 48105, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10 is soliciting quotations for the procurement and implementation of a Real-Time PCR System (Solicitation Number 36C25026Q0499) to support discovery research at the Ann Arbor VA Medical Center. The primary objective is to acquire a robust, versatile real-time PCR platform capable of high-sensitivity quantification of gene expression, genotyping, and multiplex analysis for molecular research initiatives. The system must meet specific technical specifications including 96-well or 384-well block configuration with white LED excitation source featuring OptiFlex technology, VeriFlex Block technology with six independent temperature zones, integrated touchscreen interface with cloud connectivity, and 21 CFR Part 11 compliance. The system must complete 40-cycle runs in under 30 minutes for 96-well format or 35 minutes for 384-well format and include factory calibration for ten multiple dyes (FAM, SYBR Green, VIC, NED, ABY, JUN, Mustang Purple, TAMRA, Cy5, and ROX). The offer due date is April 24, 2026 (with an alternate date of April 28, 2026 at 9:00 AM EDT noted in the RFQ), providing vendors with a brief window to submit quotations. The contracting officer is Percy Johnson, who can be reached at 614-257-5534 or percy.johnson2@va.gov.

This is an unrestricted acquisition with no set-aside designation, issued under NAICS code 334516 (Analytical Laboratory Instrument Manufacturing) with a size standard of 1,000 employees. No incumbent contractor or award value range is identified in the solicitation documents. The procurement includes the Real-Time PCR System with delivery and installation, training and knowledge transfer through orientation sessions or eLearning modules, system validation services (IQ, OQ, and IPV), and a one-year limited warranty from installation (or 15 months from shipment) with optional post-warranty service contracts offering next-business-day on-site repairs. Additional line items encompass consumables and accessories including TaqMan RNase P verification plates, 384-well hardshell plates, optical adhesive covers, and various master mixes (PowerTrack SYBR, TaqMan Fast Advanced, and SSIV VILO). The place of performance is the Ann Arbor VA Medical Center, Ann Arbor, Michigan 48105, with equipment to be delivered FOB Destination and payment made electronically in arrears after receipt, inspection, and acceptance.

Notice text

The primary objective is to implement a robust and versatile real-time PCR platform that can significantly enhance the efficiency and innovation of our discovery research, with specific emphasis on high-sensitivity quantification of gene expression, genotyping, and multiplex analysis capabilities. The research projects require a sophisticated real-time PCR platform for accurate quantitative measurements and analysis of DNA and RNA targets. The Real-Time PCR System provides the technological capabilities essential for achieving the molecular analysis goals outlined in ongoing and planned research initiatives.

The vendor will provide the Real-Time PCR System with the following specifications:

  • 96-well or 384-well block configuration with fast protocol capability
  • White LED excitation source with OptiFlex technology (6 decoupled channels for 96-well or 5 coupled channels for 384-well format)
  • VeriFlex Block technology with 6 independent temperature zones
  • Integrated touchscreen interface with cloud connectivity
  • Compliance with 21 CFR Part 11 guidelines
  • Completion of 40-cycle runs in under 30 minutes (96-well) or 35 minutes (384-well)
  • Factory calibration for multiple dyes including FAM, SYBR Green, VIC, NED, ABY, JUN, Mustang Purple, TAMRA, Cy5, and ROX

Files

File Type Posted
36C25026Q0499 rfq.docx DOCX document
Salient Characteristics.docx DOCX document
SOW.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Purchase of Rapid Syndromic Molecular Testing Reagents for Seattle VAMC Seattle, Washington 98108, United States · NAICS 325413 Veterans Integrated Service Network 20 No set-aside
6550-- Roche Ventana Reagents IDIQ 5 Successive 1 Year Delivery Orders Slvhcs New Orleans, Louisiana 70119, United States · NAICS 325413 Veterans Integrated Service Network 16 No set-aside
6550--Cepheid GeneXpert Testing Supplies Beckley Vamc Clarksburg Vamc Vamhcs Washington Vamc · NAICS 325413 Veterans Integrated Service Network 5 No set-aside
J065--Notice of Intenet to Sole Source- Life Technologies Corporation Maintenance and Service for QuantStudio 12K Flex Real-Time Quantitation System NAICS 811210 Veterans Integrated Service Network 16 No set-aside
6550--VISN 4 Coagulation Testing Pittsburgh, Pennsylvania 15215, United States · NAICS 334516 Veterans Integrated Service Network 4 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors