P-5001 joint air defense operations phase II joint base anacostia-bolling, washington, DC

Pre-Solicitation Posted

Not the latest version. See the latest solicitation from .

Solicitation number
N4008021R3502
Agency
Responses due
Not on record
Set-aside
No set-aside

Opportunity facts

Place of performance
Washington, District of Columbia 20032, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Naval Facilities Engineering Command Washington intends to issue a solicitation for a firm fixed-price construction contract to complete the second phase of the Joint Air Defense Operations Center at Joint Base Anacostia-Bolling. The project scope involves constructing a two-story facility with foundations, framing, walls, roofing and finishes along with associated site work. Special requirements include constructing a controlled access space per intelligence community standards and meeting certain architectural finishes. The solicitation is expected to post to SAM.gov in December 2021 and will utilize full and open competition under FAR Part 15 with a best value source selection process.

The pre-solicitation notice does not designate any set-asides. The contract is valued between $25-100 million and involves the construction of a permanent two-story facility to be completed within applicable Department of Defense, Air Force, and Joint Base design standards. No incumbent is named and main NAICS and PSC codes are not provided. Offerors should monitor the website for additional details and amendments to the forthcoming solicitation.

Notice text

This acquisition will result in the completion of the Joint Air Defense Operations Center permanent facility by providing the second phase of the Military Construction: Construct a two-story Joint Air Defense Operations Center. Construction includes concrete slab-on-grade foundation with Concrete spread footings under steel columns, structural steel frame, concrete masonry unit shear walls, and roofing system with sloping roof deck. Includes pavements, all utilities, site improvements, passive force protection measures, security fencing, and diverse communication routing to eliminate single points of failure and ensure constant connectivity. Special Construction Requirements include Controlled Space in accordance with Intelligence Community Directive/Intelligence Community Standard 705 and use of special exterior finishes to meet Joint Base Anacostia Bollings architectural design requirements. The facility shall be compatible with applicable Department of Defense, Air Force, and Joint Base design standards. In addition, local materials and construction techniques shall be used where cost effective. Facilities will be designed as permanent construction in accordance with the Department of Defense Unified Facilities Criteria 1-200-01. This project will comply with Department of Defense antiterrorism/force protection requirements per Unified Facility Criteria 4-010-01.

Files

File Type Posted
Presolicitation Notice-JADOC Phase II.pdf PDF

Notice history

Notice Type Posted
P-5001 DBB, joint air defense operations phase II, joint base anacostia-bolling, washington, DC Latest solicitation Solicitation
This notice Pre-Solicitation
P5001 - Notice of Intent to Sole Source - Advantor (ESS) Electronic Security System Special Notice
P5001 - Notice of Intent to Sole Source - Siemens (DDC) Direct Digital Control Special Notice
P5001 JADOC Phase II Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Joint Base Lewis McChord (JBLM) Multi Domain Task Force (MDTF) Buildings (BLDGs) 3223 and 3224 Joint Base Lewis McChord, Washington, United States · NAICS 236220 ENDIST Seattle Total Small Business
ICD-705 Controlled Spaces Modernization and Sustainment Program - (Progressive Design-build (PDB) Other Transaction Agreement (OTA) Osan Air Base Korea, South · NAICS 236220 ENDIST Far East No set-aside
Joint Base Lewis McChord (JBLM) Multi Domain Task Force (MDTF) Buildings (BLDGs) 3221 and 3222 Joint Base Lewis McChord, Washington, United States · NAICS 236220 ENDIST Seattle Total Small Business
P-271, E-130J Main Operating and Training Base, MCAS Cherry Point, NC Cherry Point, North Carolina 28533, United States · NAICS 236220 Naval Facilities Engineering Command No set-aside
Request for Information/Market Intelligence Notice: Repair Electrical Distribution System Switchgear Stations & Addition of Redundancy Cable Use of Progressive Design Build (PDB) with Other Transaction Authority (OTA) Bolling AFB, District of Columbia 20032, United States · NAICS 238210 District Washington No set-aside