Notice of Intent to Sole Source: Prismax V3 System

Closed Solicitation Posted

Solicitation number
HT941024N0125
Agency
Defense Health Agency Department of Defense
Responses due
Set-aside
No set-aside

Opportunity facts

NAICS code
339113 Surgical Appliance and Supplies Manufacturing
PSC
6515 Medical And Surgical Instruments, Equipment, And Supplies
Place of performance
San Diego, California 92134, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Defense Health Agency (DHA) is issuing a notice of intent to sole source the procurement of two Baxter PrisMax V3 Systems, which are continuous renal replacement therapy (CRRT) machines used to treat patients requiring renal replacement therapy (RRT) or renal kidney therapy (RKT). This urgent medical equipment is required for the Naval Medical Center San Diego Intensive Care Unit. The DHA intends to negotiate and award a firm-fixed price purchase order contract in accordance with the applicable Federal Acquisition Regulation (FAR) provisions due to only one source being available. Vendors interested in responding must submit a capability statement by August 16, 2024.

This procurement is not set aside for any specific business category. The estimated delivery date for the PrisMax V3 Systems and associated consumables, such as TherMax and PrisMax Warmer Arm Kits, is September 30, 2024. The place of performance is San Diego, CA 92134. The North American Industry Classification System (NAICS) code is 339113 for surgical appliance and supplies manufacturing, and the Product and Service Code (PSC) is 6515 for medical and surgical instruments, equipment, and supplies.

Notice text

The Baxter CRRT machine is effectively used to treat patients requiring RRT/RKT. The CRRT machine provides continuous, hybrid, or intermittent renal replacement therapies (RRT). It is one system for RRT and therapeutic plasma exchange (TPE) with a wide range of flow rates to meet varying patient needs. The filters utilized for the CRRT are specifically designed to eliminate blood-air interface that reduce the risk of filter clotting.

Please see attached Notice of Intent and Statement Of Work for more details.

Attachments

Files attached to this notice, newest first
File Type Posted
STATEMENT OF WORK ECHO - CRRT.docx DOCX document
HT941024N0125 NOI.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities