The Department of the Air Force Materiel Command seeks Phase I SBIR proposals for neon recovery, purification, and reliquefication technology supporting low-temperature characterization of infrared focal plane arrays, with proposals due June 12, 2024, a date that precedes the current date of November 17, 2026. The set-aside is Total Small Business, and the topic is ITAR-controlled.

The topic is DoD SBIR SF242-0018, assigned to the Sensors technology area with a Space Technology focus area. Its objective is to develop commercial products that let infrared detector characterization lab users recover, purify, and reliquefy neon gas at small scale. The NAICS code is 541715, Research and Development in the Physical, Engineering, and Life Sciences (except Nanotechnology and Biotechnology), and the PSC is AC12, Applied Research.

The attached Air Force 24.2 Phase I instructions cover 20 topics, each with a maximum value of $180,000 and a 6-month performance period. Proposals are submitted electronically through DSIP and include six volumes, with a technical volume limited to 20 pages. Subcontracts are capped at one-third of the total contract price, the awardee must perform at least two-thirds of the research effort, and all research and development must occur in the United States unless the Contracting Officer approves otherwise in writing.

Evaluation considers overall merit and security risk assessment under Section 4 of the SBIR and STTR Extension Act of 2022. The Air Force reserves the right to award all, some, or none of the proposals and expects to complete evaluations within 90 days of solicitation closure.

Notice text

DoD SBIR topic SF242-0018

Component: USAF

Command: AFMC

Phase: SBIR Program Phase I Action

Technology Areas: Sensors

Focus Areas: Space Technology

Keywords: neon; cryogenics; recovery; purification; reliquefication; infrared detectors; excimer lasers

ITAR: Yes

Objective:

The primary objective is to develop commercial products that specifically permit infrared detector characterization lab users to recover, purify and reliquefy neon gas, at the small scale (<10 liters per day of liquid neon), back into a cryogenic liquid intended for use in pour fill cryogenic dewars, and, thereby, reducing the burden of acquiring additional liquid neon.

Description:

Characterizing infrared focal plane arrays is ideally done with the test part in a pour fill dewar that uses liquid cryogens, rather than a closed-cycle system which potentially contributes noise to the test system and limits ones ability to perform focal plane array characterization at a remote facility such as a radiation source. Liquid neon is a near ideal liquid cryogen for this role. It boils at 27.5 K, which is well below liquid nitrogen and, more specifically, below where typical high performance infrared sensors operate, including long wave infrared detectors. Liquid neon also has over 40 times the refrigerant capacity per unit volume than liquid helium.[1] During a detector characterization, these two properties translate into fewer liquid cryogen transfers into the dewar using liquid neon, leaving more time for characterization. This is an absolutely indispensable advantage in the highly unique circumstance of a remote focal plane array radiation tolerance experiment, where access to the radiation source is strictly limited, rarely available and expensive, and the part must be kept cold for over a week at a time.

Unfortunately, due to some unusual circumstances, liquid neon is very expensive and difficult to come by. This is because 70% of the neon produced in the world is used in the growing semiconductor chip manufacturing industry, where argon-flourine-neon excimer pulsed lasers are the workhorse source for deep ultraviolet lithography and the ultra-high purity neon (~99.9999%) used in them must be replenished every two weeks. Additionally, neon production occurs mainly as a byproduct of nitrogen generation via cryogenic distillation of air, a technique that happened to be perfected in the Ukraine where grain production requires large amounts of nitrogen for fertilizer. Given the current difficulties in the Ukraine and its diminished production capacity and the growing use of neon in semiconductor manufacturing, the price of liquid neon has risen to roughly $3000/liter, a 600% increase since 2014. Furthermore, there is currently a single domestic distributor of liquid neon, Linde Corp. However, there is a straightforward path to alleviating some of the hardship associated with the use of liquid neon for characterizing focal plane arrays.

The technology to recover and liquefy certain gases, such as helium, at the small scale (~25 liters per day) has been commercially available for nearly a decade and has had a major impact on research and medical institutions ability to experiment, or run their instruments, at cryogenic temperatures. For example, Quantum Design North America, located in San Diego, CA, already offers a complete line of helium liquifiers and helium recovery, storage and purification systems, which allows users to recover and liquefy the exhausted helium gas currently being lost from the normal boil off and helium transfers to cryogenic instruments.[2] This technology alleviates the user's dependence on cryogen suppliers and lessens the impact of rising costs and undependable supply, as well as helps preserve a precious natural resource which is vital to scientific research and medical treatment. With some modification, a similar approach can now likely be adopted for the small scale (<10 liters per day) recovery and reliquefication of neon used in scientific research. In fact, reliquefication of exhausted neon gas was already demonstrated at the laboratory scale (~3 liters per day) in the early 1990s, but the technique was never adopted, likely due to cost and availability of liquid neon.[3]

Phase I:

Awardee(s) will perform initial technical feasibility study and develop plans for a system to recover, purify and reliquefy neon gas at the small scale for use in a detector characterization lab, or semiconductor device fa. System should be similar to existing helium reliquefiers that are currently commercially available (e.g. Quantum Design ATL160L, etc.) but with a smaller capacity of no more than 50 liquid liters and with the capability to be transportable to remote experiments. Feasibility study should also consider recovery and purification of neon from contaminated lasing gas discharged by excimer lasers used for semiconductor processing.

Phase II:

Awardee(s) will build, characterize and deliver a prototype system to recover, purify and reliquefy neon gas at the small scale for use in a detector characterization lab. System should be similar to existing helium reliquefiers that are currently commercially available (e.g. Quantum Design ATL160L, etc.) but with a smaller capacity of no more than 50 liquid liters and with some capability to be transportable to remote experiments. System characterization should show any applicability to recovery and purification of neon from contaminated lasing gas discharged by excimer lasers.

Phase III:

If a successful prototype is developed, then prototype will be commercialized to improve availability of liquid neon in DOD focal plane characterization laboratory and similar domestic laboratories across the US.

Files

File Type Posted
SF242-0018.pdf PDF
AF_SBIR_242_PI_DP2.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
High Speed, Low Temperature Hyperspectral Imager for High Enthalpy Ground Testing NAICS 541715 Air Force Materiel Command Total Small Business
Reusable Illumination System NAICS 541715 Air Force Materiel Command Total Small Business
Luminescence-Based Surface Measurement Technique for Simultaneous Pressure and Temperature Measurements within Non-Oxygen Based Hypersonic Ground Test Facilities NAICS 541715 Air Force Materiel Command Total Small Business
AFTAC Broad Agency Announcement (BAA) 2024 Patrick AFB, Florida 32925, United States · NAICS 541 Air Combat Command No set-aside
AFTAC Commercial Solutions Opening (CSO) 2024 Patrick AFB, Florida 32925, United States · NAICS 541 Air Combat Command No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors