N041--589A6-24-402, cooling tower replacement (VA-24-00061267)
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25524R0070
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Leavenworth, Kansas 66048, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 15 is seeking proposals for a project to replace the cooling towers and associated equipment at the Dwight D. Eisenhower VA Medical Center in Leavenworth, Kansas. The project, titled "N041--589A6-24-402, COOLING TOWER REPLACEMENT (VA-24-00061267)", has an estimated value between $2,000,000 and $5,000,000. The work includes replacing three vertical turbine pumps, six pneumatic control valves, and installing a side stream sand filter. Proposals are due by May 23, 2024 and the award will be made using the Lowest Price Technically Acceptable (LPTA) source selection process.
This is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSB) under NAICS code 236220 - Commercial and Institutional Building Construction. The period of performance is 365 days after the notice to proceed, with shorter durations for deductive alternates. The project is subject to the Buy American Act, Davis-Bacon Act, and other federal contracting requirements.
Notice text
7 versions
Update #7 · Latest ·
Amendment A00005 has been published below. See attachment List
Update #6 ·
Amendment A00004 has been published below. with attachments 5 and 6. See attachment List
Update #5 ·
Amendment A00002 has been published below. See attachment List
Update #4 ·
Amendment A00001 has been published below. See attachment List
Update #3 ·
Amend Factor 1 to Read: One (1) Cooling Towers Replacement Projects.
Amend Factor 2 to Read: Offerors must submit n less than One (1) examples of their successful technical construction experience with projects that involved technical requirements SIMILAR to the requirements of this project that involved construciton of Cooling Towers Replacement.
See Attaahed Solicitation 36C25524R0070
Update #2 ·
See Attaahed Solicitation 36C25524R0070
Update #1 ·
DESCRIPTION
Files
Show all 19
Notice history
| Notice | Type | Posted |
|---|---|---|
| N041--589A6-24-402, cooling tower replacement (VA-24-00061267) | Award Notice | |
| This notice | Solicitation | |
| N041--589A6-24-402, cooling tower replacement | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z1DA | replace or chillers | 580-23-105 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| CON | Z2DA | replace chiller 1 B104 | 580-24-111 | solicitation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| 657-27-107JC, Replace Select Hot Water Heating System | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business Sole Source |