Mobile Lead Radiation Shielding Barriers_Sources Sought Notice
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- 36C25526Q0604
- Agency
-
Veterans Integrated Service Network 15
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339113 Surgical Appliance and Supplies Manufacturing
- Place of performance
- Leavenworth, Kansas 66048, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
Veterans Health Administration, Veterans Integrated Service Network 15 is conducting market research for mobile lead radiation shielding barriers for pain management clinics, with sources-sought responses due August 24, 2026. The VA seeks six units: two SoloShield Mobile Radiation Barriers (model LB-HR-2438) and four Mobile Lead Barriers with glass windows (model LB-3048), or brand-name equivalents, for VA Medical Centers in Leavenworth and Topeka, Kansas.
The Mobile Radiation Barrier must feature a transparent lead acrylic window with minimum 24" x 38" viewing area providing 0.5 mm lead equivalent protection, ergonomic arm wrap-around cutouts, foot-activated hands-free height adjustment from 62" to 72", telescoping tube with locking gas spring, lightweight low-profile frame with locking casters, and minimum overall dimensions of 25.5" L x 20.5" W x 63.5" H. The Mobile Lead Barrier with glass window must include a large clear window measuring at least 48" H x 30" W constructed of shatter-resistant leaded glass providing 2.0 mm lead equivalent protection, opaque barrier panels with 2.0 mm protection, welded steel leg base with four heavy-duty locking casters, compact footprint approximately 75" to 79.5" H x 33.5" W x 24" D, and latex-free materials. All units must be delivered fully assembled or requiring only minimal setup, with no specialized vendor installation required. Installation and setup will be performed by VA Biomedical Engineering Staff. This is market research only and does not constitute a binding solicitation; responses will inform future acquisition decisions. Vendors should submit responses to Cory Rosene at cory.rosene@va.gov.
Notice text
The Vendor shall provide all equipment, materials, and services necessary to deliver fully operable Mobile Lead Radiation Shielding Barriers meeting the salient characteristics and technical requirements. Installation and setup will be performed by the VA Biomedical Engineering Staff; no on-site vendor installation is required.
Files
| File | Type | Posted |
|---|---|---|
| 36C25526Q0604.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--Mobile Lead Radiation Shielding Barriers | Solicitation | |
| This notice | Pre-Solicitation |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity