John Day Control Room Fire Protection
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- W9127N-20-R-0037
- Agency
-
ENDIST Portland
US Army Corps of Engineers, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 237990 Other Heavy and Civil Engineering Construction
- PSC
- Z2KA Repair Or Alteration Of Dams
- Place of performance
- Goldendale WA 98620 USA
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks construction services to upgrade fire protection systems for the control room at the John Day powerhouse in Goldendale, Washington. The Department of the Army Corps of Engineers Engineering District Portland is procuring the installation of fire detection and alarm systems, modifications to harden and positively pressurize the control room from an independent air supply, and addition of a master fire alarm control panel, operator interface, and multiple annunciation panels at emergency egress locations. Prospective offerors must review plans and specifications and submit any feedback or requests to view specific areas and equipment for the virtual site visit by December 14, 2020. Proposals are due by January 19, 2021 and will be evaluated based on technical qualifications, past performance, and price.
The set-aside designation for this procurement is for total small business. The primary NAICS code is 238210 and PSC code S206. The solicitation has an estimated value between $5-10 million and performance will be at the John Day powerhouse control room located in Goldendale, Washington. The work involves implementing fire detection in critical areas and control room modifications to ensure tenability and emergency egress for approximately five years following award.
Notice text
This is a construction project to lengthen tenability of the control room for controlled shutdown and emergency operation of the John Day powerhouse. The control room and its emergency egress will be fire hardened and have positive pressurization from an external independent air supply. A master fire alarm control panel and control room operator interface, and multiple fire status annunciation panels at key egress locations will be installed to provide annunciation of fire events from the powerhouse. Fire and smoke detection will be installed in the most critical areas. The work focuses on implementation of fire detection and control room modifications to ensure tenability and emergency egress from the control room during a fire event.
Due to local COVID-19 restrictions, virtual site visit will be corrdinated.
Prospective offerors are requested to review the Plans and Specifications, providing any feedback to ensure the government can provide images and videos of areas and equipment requested by offerors. To submit feedback and requests for specific areas and equipment to be viewed, please refer to section 00 23 16 INSTRUCTIONS, CONDITIONS, AND NOTICES TO OFFERORS, D. SUBMITTING QUESTIONS. Feedback and requests pertaining to the site visit must be submitted before –
December 14, 2020 at 2:00 PM PDT
Files
Show all 15
Notice history
| Notice | Type | Posted |
|---|---|---|
| John Day Control Room Fire Protection | Award Notice | |
| This notice | Solicitation | |
| John Day Control Room Fire Protection | Pre-Solicitation | |
| John Day Control Room Fire Protection | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| John day DAM unit 10 packing box replacement | ENDIST Portland | No set-aside | |
| John day DAM navigation lock tainter valve (TV) repairs TV3 and TV4 | ENDIST Portland | No set-aside | |
| TDA Isolated Phase Bus and Duct Inspection | ENDIST Portland | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity