J065--Emergency Olympus Scope Repair (632-24-1-454-0007) (VA-24-00011933)
Closed Pre-Solicitation Posted
- Solicitation number
- 36C24223Q1231
- Agency
-
Veterans Integrated Service Network 2
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Department of Veterans Affairs Northport VA Medical Center Northport NY 11768
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice is for an emergency repair of two Olympus scopes owned by the Northport VA Medical Center. The Veterans Health Administration intends to solicit from a single source, Olympus America Inc., to restore the scopes to their original specifications. The repairs include replacing all durable and non-durable components, performing any additional repairs needed, and ensuring the scopes meet watertight integrity and insulation standards. Interested parties may identify their capability to respond by October 3, 2023. The period of performance is October 13, 2023 to October 20, 2023.
There is no set-aside designated for this requirement. The NAICS code is 811210 for Electronic and Precision Equipment Repair and Maintenance. The intended source and place of performance is Olympus America Inc.'s facility in San Jose, California. The repairs must be completed during the one week period of performance stated.
Notice text
Presolicitation Notice
Presolicitation Notice
Page 4 of 4
Presolicitation Notice
*=Required Field
Presolicitation Notice
Page 1 of 4
The Veterans Health Administration, Network Contracting Office 02 intends to solicit from a single source IAW 13.106(b) to obtain an Emergency Olympus Scope Repair on two existing Olympus Scopes.
Period of performance:
Base: 10/13/2023-10/20/2023
Basic description of the requirement: The contractor shall repair EVIS EXERA III GIF-HQ190 Scope (SN: 2519753) and EVIS EXERA III CF-HQ190L Scope (SN: 2512839) for GI service in accordance with Original Equipment Manufacturer (OEM) specifications.
The contractor shall restore EVIS EXERA III GIF-HQ190 Scope (SN: 2519753) to its original equipment manufacturer specifications.
Endoscope will be fully disassembled, and all durable components will be inspected to Olympus standards.
Insertion tube, four angulation wires, bending section, bending section covering, air/water channel, and biopsy (suction) channel will be replaced with new Olympus parts.
All non-durable items (gaskets, seals, O-rings, screws, and contact pins) will be exchanged for new Olympus parts.
Additional repairs/replacements will be done which include light guide bundle replacement, light guide connector repair or replacement, tension adjustment on control knobs, body control unit refurbishment, light guide tube repair or replacement, suction cylinder and tube replacement, air/water cylinder and tube replacement, light guide lens replacement, c-body replacement, light guide cover glass replacement, switch and button replacement, c-cover replacement, and air/water nozzle replacement.
Endoscope will be leak tested to ensure watertight integrity.
Endoscope will be checked for proper insulation
The contractor shall restore EVIS EXERA III CF-HQ190L Scope (SN: 2512839) to its original equipment manufacturer specifications.
Endoscope will be fully disassembled and all durable components will be inspected to Olympus standards
Endoscope will be reassembled with a new insertion tube unit including all internal insertion tube components (CCD with objective lenses, four angulation wires, light guide bundle with lenses, air/ water channel, and biopsy (suction) channel)
Additional repairs/replacements will be down as required which include light guide connector repair or replacement, tension adjustment on control knobs, body control unit refurbishment, light guide tube repair or replacement, suction cylinder and tube replacement, air/water cylinder and tube replacement, light guide cover glass replacement, and switch and button replacement.
Endoscope will be leak-tested to insure watertight integrity and checked for proper insulation
All repairs shall be completed within contractor owned facility and without accessing Northport VA facility.
Place of Performance:
Olympus America Inc.
2400 Ringwood Avenue
San Jose, CA 95131
The NAICS code for this requirement is 811210 - Electronic and Precision Equipment Repair and Maintenance
Intended Source:
OLYMPUS AMERICA INC
3500 CORPORATE PKWY
CENTER VALLEY, PA 18034
UEI: FLWQVLFLMEL3
THIS NOTICE OF INTENT IS NOT A REQUEST FOR COMPETITIVE QUOTES. However, interested parties may identify their interest and capability to respond to this requirement by October 3, 2023 at 4:00PM Eastern Standard Time (EST).
The Department of Veterans Affairs will NOT be responsible for any costs incurred by interested parties in responding to this notice of intent. Only written responses from responsible sources will be considered. Any prospective contractor must be registered in the System for Award Management (SAM) to be eligible for award.
Interested parties are encouraged to furnish information by email only with RESPONSE TO INTENT TO SOLE SOURCE EMERGENCY OLYMPUS SCOPE REPAIR in the subject line. All documents submitted, will not be returned. All interested parties shall submit clear and convincing documentation demonstrating their capabilities to satisfy the requirements listed above to Contract Specialist Leia Labruna at Leia.Labruna@va.gov. The capability documentation should include general information and technical background describing in detail the prospective contractor's capabilities and experience that will demonstrate the ability to support these requirements.
Files
| File | Type | Posted |
|---|---|---|
| 36C24223Q1231.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Philips EPIQ CVx Ultrasound System Repair | Veterans Integrated Service Network 21 | No set-aside | |
| FY27: Replacement Dental Vacuum Pump System | Veterans Integrated Service Network 7 | Service-Disabled Veteran-Owned Small Business | |
| Surgical Instrument Maintenance – Columbia VAMC | Veterans Integrated Service Network 15 | No set-aside | |
| J066--Sakura Service Agreement | Follow on Base+4 | Start: 1/21/27 Columbus VAACC | Veterans Integrated Service Network 10 | No set-aside | |
| J066--Biosystems (Leica) | Follow On/Base +4OY's | Start Date: 2/1/27 | Columbus VAACC | Veterans Integrated Service Network 10 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity