J065--Canon Radiology CT Preventative Maintenance
Closed Pre-Solicitation Posted
Not the latest version. See the latest special notice from .
- Solicitation number
- 36C24726Q0062
- Agency
-
Veterans Integrated Service Network 7
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Charlie Norwood VA Medical Center Biomedical Engineering Section Augusta, Georgia 30901, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Network Contracting Office 7 is issuing a pre-solicitation notice for annual preventative maintenance and service support for Canon CT imaging systems at the Charlie Norwood VA Medical Center in Augusta, Georgia. The procurement specifically covers two Canon CT scanners: an Aquilion ONE PRISM Edition and an Aquilion EXCEED Large Bore CT Scanner located in the Radiology Department. The VA intends to award this as a sole-source delivery order under existing IDIQ contract SPE2D1-17-D-0022, citing that only Canon Medical Systems USA, Inc. possesses the OEM proprietary rights, certified parts, and trained professionals necessary to ensure operational integrity and patient safety. The procurement requires unlimited routine and emergency maintenance with stringent response times of two hours for phone support and eight hours for on-site response when equipment is down. Any responses challenging the sole-source determination must provide clear and convincing evidence that competition would be advantageous to the government and must be submitted by 12:00 pm EST on October 14, 2025, via email to Jessica.Cummings3@va.gov.
This procurement has no set-aside designation and Canon Medical Systems USA, Inc. is identified as both the incumbent and sole qualified contractor due to their status as the original equipment manufacturer. The contract is structured as a firm-fixed-price agreement spanning a base year plus four option years, running from November 1, 2025, through October 31, 2030, for a total potential five-year term. Service maintenance agreements under this class justification typically range from $50,000 to $1 million and will not exceed 12 months in duration. The procurement falls under NAICS code 811210 (Electronic and Precision Equipment Repair and Maintenance) with a size standard of $34 million. Services will be performed during normal hospital hours from 8am to 4:30pm, Monday through Friday, with 24/7 technical phone support available. The broader VA medical system utilizes similar maintenance agreements across approximately 170 medical facilities for various high-tech medical imaging equipment including CT scanners, MRI systems, X-ray systems, nuclear medicine equipment, and ultrasounds.
Notice text
The Department of Veterans Affairs, Network Contracting Office 7, hereby provides notice of its intent to award a sole-source delivery order under the authority of FAR 16.505(b)(2)(i)(B), "Only one source can provide the required supplies and services." Canon Medical Systems USA, Inc., a large business and the Original Equipment Manufacturer (OEM) for Canon CT systems.
This requirement will be processed against IDIQ contract SPE2D1-17-D-0022. This procurement is for annual preventative maintenance and OEM Canon CT Imagining Systems service support located at Augusta VHA medical facility.
Canon Medical Systems USA, Inc. is the only authorized source with OEM proprietary rights, certified parts, and trained professional required to provide preventative maintenance and service that ensures operational integrity, patient safety, and compliance with OEM specifications. A Limited Sources Justification has been prepared.
The NAICS Code of 811210-Electronic and Precision Equipment Repair and Maintenance with a size standard of $34 million. A Limited Sources Justification has been prepared.
This notice of intent is not a request for competitive proposals. It is not a solicitation or request for offers. No solicitation package is available. A determination not to compete is solely within the discretion of the Government. Any response to this notice must show clear and convincing evidence that competition would be advantageous to the Government. Responses must be received no later than 12:00 pm EST on Tuesday, October 14, 2025. No telephone inquiries or emails with questions will be accepted. Responses may be emailed to Jessica.Cummings3@va.gov.
Files
| File | Type | Posted |
|---|---|---|
| P03 - VHA_JEFO Canon_FINAL.pdf | ||
| SOW - Canon CT Service Contract.docx | DOCX document | |
| 36C24726Q0062_1.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| J065--Canon Radiology CT Preventative Maintenance | Special Notice | |
| This notice | Pre-Solicitation |
Similar open opportunities
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity