About this opportunity

The Department of Veterans Affairs, San Diego VA Health Care System, seeks capability statements through a sources sought notice for tri-annual electrical preventive maintenance and testing of primary substation systems, with responses due November 12, 2026 at 12:00 PM Pacific Time. The notice is market research only, is neither a solicitation nor a request for proposals, and does not obligate the Government to issue a solicitation or award a contract. The Set Aside line reads "No Set-Aside Used," and the notice invites Service-Disabled Veteran Owned, Veteran Owned, 8(a), HUBZone, and other small businesses to respond. Work is performed at 3350 La Jolla Village Drive, San Diego, CA 92161, across five buildings. Contract Specialist Chase Sullivan (chase.sullivan1@va.gov) in the Long Beach, California contracting office is the point of contact.

The scope covers inspection and NETA-standard testing of switchgear, medium and low voltage circuit breakers, oil-filled and pad-mounted transformers, protective relays, automatic transfer switches, and low voltage switchboards, plus infrared thermographic inspections, oil sampling, and a detailed engineering report. All personnel must be NICET-certified for NETA electrical power testing. The contractor supplies engineering service engineers, field technicians, tools, approved test equipment, materials, and transportation. Work must comply with VHA Directive 1028, Joint Commission standards, OSHA 1910, and NFPA 70E. The contractor must give 72 hours advance notice before servicing equipment. Weekday work runs 6:00 a.m. to 5:00 p.m. Pacific, and weekend or holiday work requires price adjustments. The base year runs December 7, 2026 through December 6, 2027 on a firm fixed price basis. No subcontracting opportunities are anticipated.

Responses must be in writing and include company details, CAGE code, Tax ID, small business type, a point of contact, and a capability statement demonstrating functional expertise. Vendors must be registered in SAM.gov and complete ORCA. SDVOSB and VOSB respondents must also register in the SBA Dynamic Small Business Search.

Notice text

This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Requests for a solicitation will not receive a response. Responses to this source sought must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential qualified Service-Disabled Veteran Owned Small Businesses, Veteran Owned Small Businesses, 8(a), HubZone and other Small Businesses interested and capable of providing the services described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area expertise and experience to compete for this acquisition. Responses to this notice shall include the following: (a) company name (b) address (c) point of contact (d) phone, fax, and email (e) DUNS number (f) Cage Code (g) Tax ID Number (h) Type of small business, e.g. Services Disabled Veteran Owned small Business, Veteran-owned small business, 8(a), HUBZone, Women Owned Small Business, Small disadvantaged business, or Small Business HUBZone business and (i) must provide a capability statement that addresses the organizations qualifications and ability to perform as a contractor for the work described below.Â

 Â

The Department of Veterans Affairs (VA), San Diego VA Health Care System (VASDHS), located at 3350 La Jolla Village Drive, San Diego, CA 92161, seeks contractor to perform electrical preventive maintenance on the facility's primary electrical substation systems. The contractor is to provide the necessary Engineering Service Engineers, tools, and approved test equipment to inspect and test the electrical equipment listed in accordance with the recommended manufacturer s procedures and National Electrical Testing Association (NETA) for switchgear assemblies, switches, medium voltage and low voltage circuit breakers, oil filled transformers, and protective relays. A comprehensive engineering report on testing data, findings, and recommendations to be furnished after completion of work. All abnormalities will be defined in a report, and any repairs must not commence without the proper authority s approval, prior to the scheduled shutdown and under normal operating conditions. Oil samples must be taken for analysis, and a comprehensive Infrared Thermographic Electrical Inspections must be conducted on all the sub-stations and respective switchgear. All components and equipment should be inspected at the highest normal load and viewed directly with covers removed wherever safely possible. The contractor will provide the necessary field service personnel, tools, materials and approved test equipment to perform Preventative Maintenance and NETA Standard testing in the equipment listed with the locations in accordance with the customer specifications and as described in the attached Preventive Maintenance Testing Guidelines excluding the optional tests.

Important information: The Government is not obligated to, nor will it pay for or reimburse any costs associated with responding to this source sought synopsis request. This notice shall not be construed as a commitment by the Government to issue a solicitation or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued. The VA is mandated by Public Law 109-461 to consider a total set-aside for Service-Disabled Veteran Owned Small Business set aside. However, if response by Service-Disabled Veteran Owned Small Business firms proves inadequate, an alternate set-aside or full and open competition may be determined. No sub-contracting opportunity is anticipated. The North American Classification System (NAICS) code for this acquisition is 238210 (Electrical Contractors and Other Wiring Installation Contractors).  Â

Â

Notice to potential offerors: All offerors who provide goods or services to the United States Federal Government must be registered in the System for Award Management (SAM) at www.sam.gov and complete Online Representations and Certifications Application (ORCA). Additionally, all Service Disabled Veteran Owned Businesses or Veteran Owned Businesses who respond to a solicitation on this project must be registered with the SBA-Dynamic Small Business Search (DSBS) Registry located at https://dsbs.sba.gov.  All interested Offerors should submit information by e-mail to chase.sullivan1@va.gov All information submissions to be marked Attn: Chase Sullivan, Contract Specialist and should be received no later than 3:00 pm EST on November 12, 2026.  Â

Files

File Type Posted
P09 - SOW.docx DOCX document
36C26227Q0112.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J061--Triennial Circuit Breaker and Feeder Testing Reno, Nevada 89502, United States · NAICS 238210 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
J059--FY27 Electrical Test and Calibrations Department of Veterans Affairs Syracuse VA Medical Center Syracuse NY 13210 · NAICS 238210 Veterans Integrated Service Network 2 No set-aside
J061--triennial electrical maintenance - amendment 4 POP: 12/01/2026 - 11/30/2027 plus 4 option years Slvhcs New Orleans, Louisiana 70119, United States · NAICS 238210 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
36-Month Electrical Distribution Testing Georgia 30033, United States · NAICS 221122 Veterans Integrated Service Network 7 Service-Disabled Veteran-Owned Small Business
657A5-26-111, Triennial Electrical Testing Marion, Illinois 62959, United States · NAICS 238210 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business Sole Source

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors