J059--Albany Transformer Testing & Service

Closed Solicitation Posted

Solicitation number
36C24226Q0928
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Veterans Health Administration VISN 2, closed Solicitation 36C24226Q0928 without award effective November 5, 2026, and will post a re-solicitation for medium-voltage transformer inspection and testing services at the Samuel S. Stratton VA Medical Center in Albany, New York. The original October 9, 2026 offer deadline and October 5, 2026 question deadline no longer apply. The structured Set Aside field reads No Set-Aside Used, while the description text states the acquisition is set-aside for SDVOSBs. The structured field governs eligibility, so confirm the set-aside status when the re-solicitation posts.

The original RFQ was issued as a commercial services combined synopsis under FAR Part 12 and covered inspection, infrared scanning, insulating liquid sampling with dielectric and water content testing, and nameplate recording. Amendment 0001 narrowed scope to inspection, infrared scanning, and oil sampling, excluding corrective maintenance, repairs, and electrical testing. It specified 20 liquid-filled transformers and approximately 8 dry-type transformers, with oil testing to include dissolved gas analysis and PCB testing. Work was to occur during overnight hours or weekends as needed, with the facility coordinating outages and performing lockout/tagout jointly with the contractor. The one-time lump-sum effort covered a November 1 to December 31, 2026 period with no option years.

Contractors must hold NETA Electrical Test Technologist certification and demonstrate five years of experience on similar major testing projects. The supervising Field Service Engineer must hold NICET/NETA certification or a BS or higher engineering degree. Contractors must supply a Qualified Registered Professional Engineer for PE oversight, and field personnel must hold NETA or NICET certification, with documentation submitted with the quotation. The RFQ cited an estimated contract value of $19 million. Evaluation considers technical capability, experience and past performance, and price, with award to the most advantageous offer. The procurement is coded NAICS 238210 and PSC J059. Contracting Officer Leia LaBruna signed the closure amendment.

Notice text

4 versions

Update #4 · Latest ·

SAM created duplicates of this solicitation. 36C24226Q0928_1 and, 36C24226Q0928_2, are both the same and have the same information within them. 

Solicitation 36C24226Q0928 shall be closed without award. Another solicitation will be posted shortly. 

This is a combined synopsis solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C24226Q0928 is issued as a request for quotation (RFQ) for inspecting and testing of medium voltage electrical transformer services. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. This acquisition is set-aside for SDVOSB.

Update #3 ·

SAM created duplicates of this solicitation. 36C24226Q0928_1 and, 36C24226Q0928_2, are both the same and have the same information within them. 

This is a combined synopsis solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C24226Q0928 is issued as a request for quotation (RFQ) for inspecting and testing of medium voltage electrical transformer services. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. This acquisition is set-aside for SDVOSB.

Update #2 ·

SAM created duplicates of this solicitation. 36C24226Q0928_1, 36C24226Q0928_2, 36C24226Q0928_3 are all the same and have the same information within them. 

This is a combined synopsis solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes only solicitation. Offers are being requested and a separate written solicitation will not be issued. Solicitation number 36C24226Q0928 is issued as a request for quotation (RFQ) for inspecting and testing of medium voltage electrical transformer services. This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov. This acquisition is set-aside for SDVOSB.

Update #1 ·

This is a combined synopsis solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes only solicitation. Offers are being requested and a separate written solicitation will not be issued.

Solicitation number 36C24226Q0928 is issued as a request for quotation (RFQ) for inspecting and testing of medium voltage electrical transformer services.

This solicitation incorporates provisions and clauses by reference. The full text of provisions and clauses may be accessed electronically at www.acquisition.gov.

This acquisition is set-aside for SDVOSB.

Files

File Type Posted
36C24226Q0928 0002.pdf PDF
36C24226Q0928 0001.docx DOCX document
36C24226Q0928 _Transformer Testing Services.pdf PDF
Wage Determination.pdf PDF
852.219-75 - LIMITATIONS ON SUBCONTRACTING.docx DOCX document

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
J059--Albany Transformer Testing & Service Solicitation
J059--Albany Transformer Testing & Service Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J061--Triennial Circuit Breaker and Feeder Testing Reno, Nevada 89502, United States · NAICS 238210 Veterans Integrated Service Network 21 Service-Disabled Veteran-Owned Small Business
H259--Essential Electrical System (EES) Switch Gear Testing Department of Veteran Affairs San Diego VA Medical Center San Diego CA 92161 · NAICS 811310 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
R425--FY 27 Service (Base+4) | NYH Energy Control Procedures/LOTO Services | 630 New York Harbor VA Healthcare System Manhattan, Brooklyn, and St. Albans VAMCs New York, New York 10010, United States · NAICS 541330 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
Automatic Transfer Switch (ATS) Preventive Maintenance and Repair Services, and Isolation Power Panel Inspection Leavenworth, Kansas 66048, United States · NAICS 238210 Veterans Integrated Service Network 15 No set-aside
CTX VAMC Maintenance, Calibration, Inspection, and Testing of the Electrical Power Distribution System Temple, Texas, United States · NAICS 811310 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors