J042--Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS
Closed Pre-Solicitation Posted
- Solicitation number
- 36C26227Q0002
- Agency
-
Veterans Integrated Service Network 22
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 541350 Building Inspection Services
- PSC
- J042 Maint/Repair/Rebuild Of Equip- Fire Fighting/Rescue/Safety Equip; Environ Protect Equip/Matls
- Place of performance
- Department of Veterans Affairs NCO 22 - Network Contracting Tucson, Arizona 85723, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Integrated Service Network 22 is procuring fire alarm, suppression systems, and hood testing, inspection, and certification services at the Tucson VA Medical Center (SAVAHCS), with a response deadline of August 14, 2026, at 3:00 PM Mountain Time. This procurement is set aside exclusively for Service-Disabled Veteran-Owned Small Business Concerns.
Place of performance is the Tucson VA Medical Center, 3601 S. 6th Avenue, Tucson, Arizona 85723.
Service requirements include semi-annual fire sprinkler system inspections (130 units with tamper and flow switches), annual main drain flow tests (130 risers), five-year internal sprinkler inspections (33 systems over the contract period, averaging 6 annually), annual fire extinguisher hydrostatic testing (120 units), annual fire alarm inspections per NFPA 72 with 100% device testing and monthly sectional testing, semi-annual kitchen hood inspections (6 units, including 2 CORE-certified water washdown systems), quarterly kitchen hood inspections (5 units, 4 times annually), quarterly fire hydrant inspections (30 units, 1 annually), quarterly fire department connection inspections (34 units), monthly exit light inspections (1,500 units), and annual rolling fire door inspections. All fire alarm work must be performed by NICET III-certified Notifier technicians. The contractor must provide a web-based reporting system with five-year data retention, annual AutoCAD fire alarm drawing updates, 8-hour annual hands-on Notifier training for up to 10 VA personnel, and 24/7 offsite monitoring with VA-supplied dialers. The contractor receives two facility badges with access limited to non-sensitive areas; VA staff will escort into sensitive areas. Repairs, replacement parts, and emergency labor are excluded from base contract pricing and funded separately by the VA.
The contracting office is Network Contracting Office 22. Contract Specialist Mirna Gastelum Romero (Mirna.GastelumRomero@va.gov) is the primary point of contact.
Notice text
Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS
Files
| File | Type | Posted |
|---|---|---|
| S06 36C26227Q0002 0003 Amendment.pdf | ||
| 36C26227Q0002_5.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Pre-Solicitation | |
| J042--Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS | Solicitation | |
| J042--Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J042--Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| H379-- Facility Hood Cleaning and Inspection | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| H112--Secutron Fire Alarm testing and Maintenance at the VA Northern California Health Care System (VANCHCS) | Veterans Integrated Service Network 21 | No set-aside | |
| J012-- Fire Alarm Suppression Maintenance & Repair Services | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--Upgrade Fire Alarm System Construction 676-22-110 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity