J041--OBVAMC Chiller Maintenance Service
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25626Q1117
- Agency
-
Veterans Integrated Service Network 16
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- J041 Maint/Repair/Rebuild Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
- Place of performance
- Overton Brooks VA Medical Center Shreveport LA 71101
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
Veterans Integrated Service Network 16 is issuing a Request for Information (RFI) to identify contractors capable of providing chiller maintenance services at Overton Brooks VA Medical Center in Shreveport, Louisiana, with responses due by July 30, 2026 at 10:00 a.m. CST. This is a pre-solicitation notice with no set-aside, PSC J041 (NAICS 238220).
Work covers preventative maintenance, inspections, testing, and cleaning on three York chillers and one Trane chiller, plus four Evapco cooling towers. The contract runs October 1, 2026 through September 30, 2027, with four optional one-year renewal periods extending through September 30, 2031. Contractor qualifications must include EPA 608 Universal Certification, Louisiana HVAC licensure if required, OSHA ten-hour safety training, and VA Medical Center safety protocol training including lockout-tagout procedures.
Performance requirements include monthly preventative maintenance tasks (oil checks, motor testing, voltage verification, refrigerant leak testing), annual maintenance (electrical tightening, megohm testing, filter and drier replacement, oil and vibration analysis, tube cleaning, heat exchanger flushing), and cooling tower maintenance (deck and sump cleaning, component inspection, five-year oil changes, control verification). Emergency response is required within four hours for full system outages affecting patient care and within twenty-four hours for non-critical issues. Deliverables include monthly reports within forty-eight hours and annual/cooling tower inspection reports within five business days.
The Quality Assurance Surveillance Plan establishes 100 percent compliance requirements for scheduled maintenance, 95 percent pass rates for cooling tower inspections on first attempt, and 95 percent on-time reporting targets. Performance incentives offer quarterly bonuses up to three percent and annual excellence awards up to five percent. Liquidated damages range from 0.25 percent per day for late monthly reports to one percent per hour for emergency response delays beyond four hours.
Contact: Alan Scanio, Contract Specialist, at alan.scanio@va.gov.
Notice text
The National Contracting Office No. 16 hereby issues the following Request for Information (RFI) with the intent of determining the interest, capabilities, and qualifications of potential businesses. This RFI is to seek contractors with the capability to provide OBVAMC Chiller Maintenance Services to the Overton Brooks VA Medical Center.
Responses are due by 07/30/2026 at 10:00 a.m. (CST)
Please review all attachments.
Files
| File | Type | Posted |
|---|---|---|
| DRAFT PERFORMANCE WORK STATEMENT.docx | DOCX document | |
| 36C25626Q1117_1.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | No set-aside | |
| 4120--rental of two chillers for one year | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| H265--BD Alaris Infusion Pumps Preventative Maintenance Services | Veterans Integrated Service Network 16 | No set-aside | |
| J041--Condenser Coils Replacement for the VA Illiana Health Care System (VAIHCS), located at 1900 E. Main Street, Danville, IL 61832. | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| J041--Preventive and Corrective Maintenance for Ice Machines | Veterans Integrated Service Network 17 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity