J041--Air Cooled Chiller Rental - Wilkes-Barre VAMC

Closed Pre-Solicitation Posted

Solicitation number
36C24425Q0367
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Wilkes-Barre Vamc Wilkes-Barre PA 18711

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration (VA) is seeking potential sources for air-cooled chiller rental services at the Wilkes-Barre VA Medical Center in Pennsylvania. The procurement involves supplying two 500-ton air-cooled chillers for the main plant and one 250-ton air-cooled chiller for the North building, along with a diesel-powered generator. Key contract requirements include delivery, installation, interconnecting water and electrical lines, 24/7 emergency service, periodic maintenance, and operational training for VA maintenance personnel. Evaluation criteria will focus on vendors' capability statements, socio-economic status, and ability to meet technical specifications outlined in the sources sought notice. Responses to this pre-solicitation notice are due by February 26, 2025, at 12:00 PM EST, with interested vendors required to be registered in the System for Award Management (SAM) database.

The procurement has no specific set-aside designation, but the VA is particularly interested in responses from Service-Disabled Veteran-Owned Small Businesses (SDVOSBs) and Veteran-Owned Small Businesses (VOSBs) in accordance with Kingdomware requirements. The contract will be for a seven-month period from April 1 to October 31, 2024, with work restricted to Monday through Friday, 6:00 AM to 5:00 PM. While no specific award value is mentioned, the scope includes providing trailer-mounted chillers with onboard pumping systems, programmable controls, and a standby generator. Vendors must be classified under NAICS code 532490 (Other Commercial and Industrial Machinery and Equipment Rental and Leasing) and will be required to provide detailed information about their socio-economic status, including whether they are a small business, veteran-owned, HUB Zone certified, or woman-owned enterprise.

Notice text

The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre-

Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or

proposals at this time; however, reserves the right to do so at a later date. The Wilkes-Barre VAMC in Wilkes-Barre, PA 18711 is seeking potential sources for the following services for Chiller Rental.

ALL WORK TO BE COMPLETED AT THE FOLLOWING LOCATION:

Wilkes-Barre VAMC

1111 East End Blvd

Wilkes-Barre, PA 18711

ALL INTERESTED PARTIES MUST ALSO HAVE AN ACTIVE REGISTRATION IN THE SYSTEM FOR AWARD MANAGEMENT (SAM) DATABASE. TO REGISTER, PLEASE VISIT WWW.SAM.GOV.

Responses to this notice shall include:

Company Name

Address

Point of Contact

Phone Number

Email Address

UEI Number

CAGE Code

Tax ID Number

** Note: In accordance with the U.S. Supreme Court decision regarding Kingdomware, service

disabled veteran owned (SDVOSB) and veteran owned (VOSB), who are interested in this

procurement and consider themselves to have the resources and capabilities necessary to

provide these services shall be verified in Veteran Small Business Certification (VetCert) as follows to be considered: https://veterans.certify.sba.gov/

Process in 38 U.S.C. 8127(d) whereby a contracting officer of the Department shall award contracts on the basis of competition restricted to small business concerns owned and controlled by veterans, if the contracting officer has a reasonable expectation that two or more small business concerns owned and controlled by veterans will submit offers, and that the award can be made at a fair and reasonable price that offers the best value to the United States. For purposes of this VA specific rule, a service-disabled veteran-owned small business (SDVOSB) or a veteran-owned small business (VOSB), must meet the eligibility requirements in 38 U.S.C. 8127(e), (f) and VAAR subpart 819.7003 and be listed as verified in the Vendor Information Pages (VIP) database.

Please provide answers to all questions below regarding your firm s Socio-Economic status pursuant to

North American Industrial Classification Code (NAICS) 532490:

1. Is your business a small business under NAICS 532490? YES ______ NO ______

2. Is your firm a Veteran-Owned Small Business? YES ______ NO ______

3. Is your firm a Service-Disabled Veteran-Owned Small Business? YES ______ NO ______

4. Is you firm a certified HUB Zone firm? YES ______ NO ______

5. Is your firm a Woman Owned business? YES ______ NO ______

6. Is your firm a Large Business? YES ______ NO ______

7. Do you have a GSA/FSS schedule for these items? YES______ NO______

Schedule Number: ___________________

Expiration Date: _____________________

Please provide a capability statement as well as any relevant literature addressing your organizations

ability to supply the required items. Also, please include a point of contact name, phone number and

email address.

Note: Questions regarding this notice should be addressed to Jennifer Beiswenger via email only. NO PHONE CALLS WILL BE ACCEPTED REGARDING THIS REQUIREMENT.

Please submit all responses to this notice via e-mail to:

Jennifer Beiswenger

Contract Specialist

Jennifer.Beiswenger@va.gov

Responses to this Sources Sought Notice are required by no later than Wednesday, February 26, 2025, at 12:00 pm EST.

Introduction 1.0

The Wilkes Barre VAMC is a mission critical facility and is located at 1111 East End Boulevard, Wilkes Barre PA. This facility has a requirement for supplementing the existing main chiller system during the upcoming cooling season. This will be accomplished by connecting air-cooled stand-alone chillers to the existing taps. The requirement will be for a period of seven (7) months beginning, April 1, 2024, and ending October 31, 2024.

Scope 2.0

2.1 This requirement is for supplying two (2) 500-ton air cooled chillers to support the main chiller plant and one (1) 250-ton air-cooled chiller that will support the North building at this facility. The chillers at the main plant will need to be supported electrically by a standby generator. The chiller for the North building will need to be electrically connected to the twist lock electrical panel that is connected to this facility s 1200 AMP electrical utility.

Equipment Requirements 3.0

3.1 The air-cooled chillers for the main plant shall have a capacity of 500 tons each.

3.2 The air-cooled chiller for the North building shall have a capacity of 250 tons.

3.3 Each chiller shall be programable and automated to maintain a chilled water setpoint.

3.4 Each chiller shall have an onboard pumping system.

3.3 Each chiller and generator shall be trailer mounted.

3.4 Diesel powered generator with manual start capable of providing power to run two 500-ton air-cooled chiller.

Contractor Requirements 4.0

4.1 Contractor shall include delivery and pick-up of equipment.

4.2 The contractor is responsible for setting the equipment in the areas designated by the Wilkes Barre VAMC.

4.3 The contractor is responsible for supplying the interconnecting chilled water lines between the equipment and the existing system taps.

Note: The existing system taps are six inch (6 ) grooved type connections and are within two hundred fifty feet (250 ) of equipment location site.

4.4 The contractor shall install and fill all interconnecting chilled water lines.

4.5 The contractor shall supply and terminate interconnecting electrical cabling between the generator and the two 500-ton chillers.

4.6 The contractor shall supply and terminate interconnecting electrical cabling between the building 1200 AMP utility (Twist lock connections) and the 250-ton chiller.

4.7 The contractor shall provide start-up and operational training to the VAMC maintenance personnel.

4.8 The contractor shall assume 24/7 equipment runtime.

4.9 The contractor shall provide required periodic maintenance on all equipment.

4.10 The contractor shall provide 24/7 emergency service on the equipment provided.

5.0 Deliverables

5.1 The contractor shall place all equipment onsite to minimize interconnecting piping and cabling length requirements.

5.2 All equipment and deliveries and pickups must be scheduled with the Maintenance and Operations Supervisor two weeks in advance.

5.3 All equipment deliveries and pickups must be conducted before 7:00AM.

5.4 All work shall be performed Monday through Friday during Operation Hours Only (6:00 AM- 5:00 PM). No work shall be conducted on Federal Holidays and/or Weekends.

Files

File Type Posted
Sources Sought 36C24425Q0367.pdf PDF
36C24425Q0367.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Rental of two chillers for one year Asheville, North Carolina 28805, United States · NAICS 238220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
CON | Z1DA | replace or chillers | 580-23-105 | solicitation Houston, Texas 77030, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Chiller NAICS 333415 Land and Maritime No set-aside
Rental of 2 60-ton Chill Water System Portsmouth, Virginia 23709, United States · NAICS 532490 Naval Sea Systems Command Total Small Business

On GovTribe

Work this opportunity