Insulated Bldg. 141 Roll Up Doors
Closed Solicitation Posted
- Solicitation number
- W50S6M-25-Q-A016
- Agency
-
Alabama National Guard
Army National Guard, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 332321 Metal Window and Door Manufacturing
- PSC
- 5670 Building Components, Prefabricated
- Place of performance
- Birmingham, Alabama 35217, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Alabama Army National Guard is procuring roll-up door installation services at Building 141 located in Birmingham, Alabama. The project involves removing three existing roll-up doors and installing two TKO CW Series Cruiserweight Impactable doors and one insulated roll-up door, with specifications requiring high R-23 insulation value, tight perimeter weather sealing with double loop seals, moisture resistance, and 1-3/4" thick insulated foam core panels consistent with previously installed doors in Building 190. The work encompasses all labor, materials, equipment, and supervision necessary for complete installation, including proper disposal of existing doors and any required structural adjustments. Evaluation will be based on Technical Acceptability (meeting Attachment 1 specifications), Price, and Past Performance, with technical and past performance considerations approximately equal to price in importance. The quote response deadline is August 21, 2025, at 1:00 p.m. CST, with quotes submitted via email to designated points of contact Jonathan Werkmeister and William Hall.
This opportunity is designated as a Total Small Business set-aside under NAICS code 332321 (Metal Window and Door Manufacturing) with a size standard of 750 employees. No incumbent contractors or current service providers are identified in the solicitation documents. While specific award values or budget ranges are not disclosed, the contract will be a Firm-Fixed Price arrangement with a 90-day delivery period following contract award. The installation will take place at Building 141, located at 5401 E. Lake Blvd, Birmingham, AL 35217, at the Sumpter Smith Air National Guard Base. All doors will be manually operated without motor operators, and the installation will require mounting door tracks below ceiling tiles using threaded rod and brackets while minimizing disruption to the existing ceiling grid system.
Notice text
2 versions
Update #2 · Latest ·
RFI answers 20 Aug 2025
Roll-Up Doors Description
1.2.1.1 This project involves the removal of three existing roll-up doors and the installation of two TKO CW Series Cruiserweight Impactable doors and one insulated roll-up door at Building 141. With a crane already installed within the middle bay door opening, preventing the necessary clearance and hardware installation, we are proceeding with a single roll-up door instead of a sectional door. The work includes all labor, materials, equipment, and supervision necessary for the complete and functional installation of the new doors, including proper disposal of the old doors and any necessary adjustments to the existing structure. New doors must be consistent with already installed Cruiserweight Impactable TKO door in Bldg. 190 (high R-23 value in temperature-controlled environments and includes a tight perimeter weather seal with a double loop seal to prevent energy loss, moisture-resistant, 1-3/4" thick insulated foam core panel insulated doors specifications).
Dimensions and all other information can be found in the Statement of Requirment and Solicitation Synopsis Documents.
Update #1 ·
Roll-Up Doors Description
1.2.1.1 This project involves the removal of three existing roll-up doors and the installation of two TKO CW Series Cruiserweight Impactable doors and one insulated roll-up door at Building 141. With a crane already installed within the middle bay door opening, preventing the necessary clearance and hardware installation, we are proceeding with a single roll-up door instead of a sectional door. The work includes all labor, materials, equipment, and supervision necessary for the complete and functional installation of the new doors, including proper disposal of the old doors and any necessary adjustments to the existing structure. New doors must be consistent with already installed Cruiserweight Impactable TKO door in Bldg. 190 (high R-23 value in temperature-controlled environments and includes a tight perimeter weather seal with a double loop seal to prevent energy loss, moisture-resistant, 1-3/4" thick insulated foam core panel insulated doors specifications).
Dimensions and all other information can be found in the Statement of Requirment and Solicitation Synopsis Documents.
Files
| File | Type | Posted |
|---|---|---|
| Roll Up Door Questions Answers.docx | DOCX document | |
| Attachment 1 Solicitation -.docx | DOCX document | |
| Attachement 2 Statement of Requirement.docx | DOCX document | |