Inspect & Test the Electrical Power Distribution System

Closed Pre-Solicitation Posted

Solicitation number
36C25926Q0848
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Oklahoma 74401, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 19 (NCO 19) is conducting a sources sought notice for construction services to inspect, test, and repair the electrical power distribution system at the Muskogee VA Medical Center in Muskogee, Oklahoma, with responses due September 14, 2026 at 10:00 AM Mountain Time.

This is a market research notice only; no contract award will result from responses submitted, and the Government makes no commitment to issue a subsequent solicitation. Respondents should submit company name and address, point of contact information, SAM UEI Number, small business certifications, annual revenue documentation, and confirmation of ability to perform 50 percent or more of the identified scope to Mark.Holland@va.gov.

The work covers inspection, testing, maintenance, and calibration of electrical power distribution systems serving approximately 889,161 square feet at voltages of 480V, 277V, 208V, and 120V, with 12.47 KV distribution voltage. Scope includes cleaning and thermal imaging of transformers, testing and replacing cooling liquids in liquid-cooled units, circuit breaker exercising and testing, ground resistance testing, GFCI testing and documentation, and infrared thermal detection. All work must comply with VA Directive 1028 and NFPA 70E requirements.

Contractor qualifications require minimum five years of continuous experience in electrical power distribution system maintenance and testing in healthcare, industrial, educational, or commercial facilities. Field engineers must hold NETA or NICET certification, complete OSHA 10-hour construction safety training, and possess current professional references including NFPA 70, 70B, 70E, 110, OSHA 29 CFR 1910, and NETA maintenance specifications. A comprehensive report including test data, equipment status, deficiencies, and corrective actions must be delivered within 45 days of field work completion.

NAICS 238210; PSC Z1DA.

Notice text

The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for construction services to include the Inspection, testing, and repair of the electrical power distribution system at the Muskogee Oklahoma VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided. 

See Sources Sought attachment for further details. 

Files

File Type Posted
Sources Sought Notice_36C25926Q0848.pdf PDF

Similar open opportunities

Opportunity Agency Set-aside Responses due
J061--541 Electrical Power Distribution Equipment Testing, Inspection, and Maintenance - VAMC Cleveland Department of Veterans Affairs Louis Stokes Cleveland VA Medical Center, Ohio 44106, United States · NAICS 238210 Veterans Integrated Service Network 10 Total Small Business
J059--Uninterruptible Power Supply (UPS) Preventive Maintenance Base 4 Option Years (VA-27-00009247) Oklahoma City VA Medical Center Oklahoma City OK 73104 · NAICS 811210 Veterans Integrated Service Network 19 No set-aside
C211--589A6-24-410, Replace MDP Panel Bld 89| EKH Dwight D. Enisenhower VA Medical Center Leavnworth Leavenworth Kansas 66048 · NAICS 238210 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business
657A5-26-111, Triennial Electrical Testing Marion, Illinois 62959, United States · NAICS 238210 Veterans Integrated Service Network 15 Service-Disabled Veteran-Owned Small Business Sole Source
Z1DA--NRM| 460-26-007 Electrical Distribution Inspection Repairs | NCO 4 Construction East (VA-26-00057558) Department of Veterans Affairs Wilmington DE 19805 · NAICS 236220 Veterans Integrated Service Network 4 Service-Disabled Veteran-Owned Small Business