HVAC Vent Cleaning

Closed Solicitation Posted

Solicitation number
FA301626Q0119
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
Jbsa Lackland, Texas 78236, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force seeks one-time comprehensive HVAC air duct and vent cleaning and sanitization services at Building 5311, JBSA-Lackland, San Antonio, Texas, with proposals due June 2, 2026 at 11:00 a.m. CDT. The procurement is a total small business set-aside, foreclosing competition outside that pool.

Place of performance is Building 5311 at JBSA-Lackland, Texas 78236, approximately 10,000 square feet with typical 8-foot ceiling heights. The scope includes deep cleaning of supply and return vent grilles, internal cleaning of two air handler units and associated blower assemblies, supply ductwork, and main trunk lines, plus system sanitization and deodorization using EPA-approved sanitizers. The contractor shall service existing UV light air purification systems (REME HALO) if present. All personnel must obtain base identification and vehicle passes prior to work commencement and must provide federally authorized identity documentation and undergo character and conduct vetting as required by the Department of Defense. A mandatory site visit is scheduled for May 28, 2026 at 10:00 a.m.; contractors must contact Contract Specialist A1C Noah Emerson (noah.emerson.1@us.af.mil, 210-671-3874) by May 27, 2026 at 1:00 p.m. to register and obtain base access.

The NAICS code is 561790, Other Services to Buildings and Dwellings; PSC is J011. Award will be made to the responsible, responsive contractor offering the lowest price that is technically acceptable, evaluated on three factors: Technical (how well proposed services meet requirements), Past Performance (from Contractor Performance Assessment Reporting System and commercial market experience), and Price (inclusive of transportation). Offerors must hold prices firm for 60 calendar days from the due date. Prevailing wage rates under Department of Labor Wage Determination 2015-5253 (Revision 29, effective May 13, 2026) apply.

Notice text

3 versions

Update #3 · Latest ·

The Contractor shall provide all necessary labor, tools, equipment, materials, and supervision required to perform a comprehensive, one-time cleaning of the Heating, Ventilation, and Air Conditioning (HVAC) air duct and vent systems at the designated facility. The work involves deep cleaning and sanitization of both internal and external components of the HVAC system. Reference Attachment 1- Statement of Work.

Amendment 0001

Site Visit: A site visit will be conducted on Thursday 28 May 2016 at 10:00 A.M. All interested Contractor must contact Contract Specialist A1C Noah Emerson at noah.emerson.1@us.af.mil, no later than 27 May 2026 by 1:00 P.M. Contractors will be required to obtain base access on that day. Contractors will meet at the Luke Gate Visitor Center of Military Dr by 8:30 a.m.

Amendment 0002

Attachment 3 Questions and Answers

Attachment 4 Floor Plan

Update #2 ·

The Contractor shall provide all necessary labor, tools, equipment, materials, and supervision required to perform a comprehensive, one-time cleaning of the Heating, Ventilation, and Air Conditioning (HVAC) air duct and vent systems at the designated facility. The work involves deep cleaning and sanitization of both internal and external components of the HVAC system. Reference Attachment 1- Statement of Work.

Amendment 0001

Site Visit: A site visit will be conducted on Thursday 28 May 2016 at 10:00 A.M. All interested Contractor must contact Contract Specialist A1C Noah Emerson at noah.emerson.1@us.af.mil, no later than 27 May 2026 by 1:00 P.M. Contractors will be required to obtain base access on that day. Contractors will meet at the Luke Gate Visitor Center of Military Dr by 8:30 a.m.

Update #1 ·

The Contractor shall provide all necessary labor, tools, equipment, materials, and supervision required to perform a comprehensive, one-time cleaning of the Heating, Ventilation, and Air Conditioning (HVAC) air duct and vent systems at the designated facility. The work involves deep cleaning and sanitization of both internal and external components of the HVAC system. Reference Attachment 1- Statement of Work.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Troubleshoot & Repair of Portable Chillers Service Requirement Jbsa Lackland, Texas 78236, United States · NAICS 238220 Air Education and Training Command Total Small Business
EOS Custodial Service Joint Base MDL, New Jersey 08641, United States · NAICS 561720 Air Mobility Command Competitive 8(a)
Cleaning of Food Service Exhaust Fans and Ducts for Dining Facilities in USAG Yongsan-Casey. Dongducheon Gyeonggi Korea, South · NAICS 561790 Army Contracting Command No set-aside
DCDO - HVAC Maintenance 96367 Japan · NAICS 238220 Pacific Air Forces No set-aside
Small Arms Firing Range (SAFR) Cleaning and Maintenance Services Cannon AFB, New Mexico 88103, United States · NAICS 562910 Air Force Special Operations Command Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity