Hanger 9 Renovation at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
MrktSrvy2-Hanger9-MMAC
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

PSC
Not on record
Place of performance
Oklahoma City, Oklahoma 73169, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Transportation Federal Aviation Administration Franchise Acquisition Services is conducting a market survey for the Hanger 9 Renovation project at the Mike Monroney Aeronautical Center in Oklahoma City, OK. The work to be performed includes upgrading the restrooms, lighting, finishes, and life safety and accessibility features within the hangar. Respondents should provide a capability statement detailing their firm's services, size, years in business, and socio-economic status, as well as information on past similar projects. Responses to the market survey are due by September 27, 2024, at 4:00 pm CT, and should be submitted via email to the provided address. The survey responses will be used for informational and procurement planning purposes only, and the FAA will not pay for any costs associated with the submission.

This opportunity is not set-aside for any specific business designation. The FAA has not provided any information about potential incumbent contractors or the expected award value. The notice does not specify a quantity of goods or a timeline for the services to be provided.

Notice text

2 versions

Update #2 · Latest ·

*********************THIS IS A MARKET SURVEY ONLY********************
- This is not a Screening Information Request or Request for Proposals of any kind;
- The FAA is not seeking or accepting unsolicited proposals;
- The FAA will not pay for any information received or costs incurred in preparing the response to the market survey; and
- Any costs associated with the market survey submittal are solely at the interested vendor’s expense.
*************************************************************************************

This is a market survey for a construction project titled: Hanger 9 Renovation at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK.

Work to be accomplished for the Hanger 9 Renovation includes but not limited to the following:

  • Existing restrooms renovation requirements. 
    1. Upgrade plumbing fixtures and restroom accessories to meet all applicable building and civil codes and other federal, state, city, and local ordinances and regulations.
    2. Reconfigure and modify the water and sanitary systems at all restrooms being renovated and as indicated in the contract documents.
    3. Upgrade finishes to meet current FAA finish standards.
    4. Replace drinking fountains with filtered bottle filler fountains.
  • Lighting and finishes upgrade requirements.
    1. Remove existing exit signs and provide and install new LED exit signs.
    2. Remove existing interior non-LED light fixtures and provide and install new interior LED fixtures.
    3. Provide and install a new lighting control system.
    4. Replace existing ceiling tile and grid in locations with lighting replacement work and in all stairwells.
    5. Replace existing carpet tile and wall base in locations with lighting work, wall configuration changes, or where existing is worn or damaged.
    6. Patch, repair, and paint existing walls in locations where carpet tile is replaced and in all stairwells.
  • Life safety and accessibility construction requirements.
    1. Seal penetrations within the fire barriers separating the hangar high bays from the hangar administration spaces with fire rated sealant or fire stops.
    2. Remove and seal abandoned air transfer openings in stairways.
    3. Infill resulting openings to maintain wall fire rating
    4. Adjust doors on path of egress to meet accessible push/pull clearances where indicated in the contract documents, including changing door swing directions, and enlarging door widths.
    5. Replace stair treads at existing stairs where indicated in the contract documents to reduce potential trip hazards.
    6. Construct accessible egress ramps at 1st floor exit doors currently lacking accessible means of egress. See contract drawings for locations.
    7. Provide and install “NO EXIT” door signs on unmarked doors that could be confused for exit doors.
    8. Provide and install emergency exit signage at exterior doors where indicated on the contract drawings.
    9. Provide and install additional fire extinguisher and eyewash station signage on existing columns below the netting in the hangar High Bays.
    10. Enclose existing ducts that pass-through stairwells in fire rated chases.
    11. Modify existing sprinkler system components in areas of renovation to provide complete coverage. Provide and install new sprinkler system components where required. Do not reuse existing sprinklers that were previously removed.
    12. Replace all fire alarm notification and initiating devices within Hangar 09 with new devices compatible with the existing fire alarm panel.
  • Mechanical and Plumbing construction requirements.
    1. Remove all existing pneumatic combination smoke/fire dampers and their associated control actuators and replace with electronic smoke/fire dampers and electric actuators.
    2. Remove existing pneumatic control compressor.
    3. Adjust existing diffuser layout to accommodate new lighting layout.
    4. Provide and install new return air pathways in areas where existing lights and troffers are replaced with LED lights.
    5. Replace drinking fountains with filtered bottle filler fountains.
    6. Reconfigure and modify the water and sanitary systems at all restrooms being remodeled as part of the architectural scope.
  • Miscellaneous construction requirements.
    1. Repaint all hangar high bay walls, removing and reinstalling bird netting as required. Paint as scheduled in the contract drawings.
    2. Repaint and restripe the Hangar 8 High Bay floors to match existing.
    3. Remove existing RF shielding walls, floors, and ceilings at Hangar 09 3rd floor east and replace with stud and drywall construction, new ceilings, and flooring.
    4. Renovate break room at Hangar 9 3rd floor east located in RF shielded room.

 Market Survey Response should include the following:

1. Capability Statement - This document should identify:
- Type of services provided by firm,
- Size and type of services provided on previous government/private sector contracts 
- Number of years in business
- Small Business Size Status to include applicable socio-economic information such as 8(a), WOSB, SDVSB, etc.

2. Detailed information (Agency or Customer/Dollar Amount/Scope/etc.) regarding past projects respondent has completed with similar work to work identified in this Market Survey.

Respondents must be active in the System for Award Management (SAM) (www.sam.gov).

All responses to this market survey must be received by Friday, September 27th, 2024, 4:00 p.m. CT. All capability statements must be submitted by email to: andre.casiano@faa.gov.

The responses to this market survey will be used for informational and procurement planning purposes only. This is not a screening information request or request for proposal of any kind. The FAA is not seeking or accepting proposals at this time.

The FAA will not pay for any information received or costs incurred in preparing the response to the market survey. Therefore, any cost associated with the market survey submission is solely at the interested vendor's expense.

---UPDATE Sept 19, 2024---
REMINDER: THIS IS NOT A SCREENING INFORMATION REQUEST OR REQUEST FOR OFFEROR -

Disclosure of the Size of Construction Projects: This potential project is estimated to be between $5,000,000 and $10,000,000

*********************THIS IS A MARKET SURVEY ONLY********************
- This is not a Screening Information Request or Request for Proposals of any kind;
- The FAA is not seeking or accepting unsolicited proposals;
- The FAA will not pay for any information received or costs incurred in preparing the response to the market survey; and
- Any costs associated with the market survey submittal are solely at the interested vendor’s expense.
*************************************************************************************

Update #1 ·

********************************MARKET SURVEY********************************
- This is not a Screening Information Request or Request for Proposals of any kind;
- The FAA is not seeking or accepting unsolicited proposals;
- The FAA will not pay for any information received or costs incurred in preparing the response to the market survey; and
- Any costs associated with the market survey submittal are solely at the interested vendor’s expense.
*************************************************************************************
This is a market survey for a construction project titled: Hanger 9 Renovation at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK.

Work to be accomplished for the Hanger 9 Renovation includes but not limited to the following:

  • Existing restrooms renovation requirements. 
    1. Upgrade plumbing fixtures and restroom accessories to meet all applicable building and civil codes and other federal, state, city, and local ordinances and regulations.
    2. Reconfigure and modify the water and sanitary systems at all restrooms being renovated and as indicated in the contract documents.
    3. Upgrade finishes to meet current FAA finish standards.
    4. Replace drinking fountains with filtered bottle filler fountains.
  • Lighting and finishes upgrade requirements.
    1. Remove existing exit signs and provide and install new LED exit signs.
    2. Remove existing interior non-LED light fixtures and provide and install new interior LED fixtures.
    3. Provide and install a new lighting control system.
    4. Replace existing ceiling tile and grid in locations with lighting replacement work and in all stairwells.
    5. Replace existing carpet tile and wall base in locations with lighting work, wall configuration changes, or where existing is worn or damaged.
    6. Patch, repair, and paint existing walls in locations where carpet tile is replaced and in all stairwells.
  • Life safety and accessibility construction requirements.
    1. Seal penetrations within the fire barriers separating the hangar high bays from the hangar administration spaces with fire rated sealant or fire stops.
    2. Remove and seal abandoned air transfer openings in stairways.
    3. Infill resulting openings to maintain wall fire rating
    4. Adjust doors on path of egress to meet accessible push/pull clearances where indicated in the contract documents, including changing door swing directions, and enlarging door widths.
    5. Replace stair treads at existing stairs where indicated in the contract documents to reduce potential trip hazards.
    6. Construct accessible egress ramps at 1st floor exit doors currently lacking accessible means of egress. See contract drawings for locations.
    7. Provide and install “NO EXIT” door signs on unmarked doors that could be confused for exit doors.
    8. Provide and install emergency exit signage at exterior doors where indicated on the contract drawings.
    9. Provide and install additional fire extinguisher and eyewash station signage on existing columns below the netting in the hangar High Bays.
    10. Enclose existing ducts that pass-through stairwells in fire rated chases.
    11. Modify existing sprinkler system components in areas of renovation to provide complete coverage. Provide and install new sprinkler system components where required. Do not reuse existing sprinklers that were previously removed.
    12. Replace all fire alarm notification and initiating devices within Hangar 09 with new devices compatible with the existing fire alarm panel.
  • Mechanical and Plumbing construction requirements.
    1. Remove all existing pneumatic combination smoke/fire dampers and their associated control actuators and replace with electronic smoke/fire dampers and electric actuators.
    2. Remove existing pneumatic control compressor.
    3. Adjust existing diffuser layout to accommodate new lighting layout.
    4. Provide and install new return air pathways in areas where existing lights and troffers are replaced with LED lights.
    5. Replace drinking fountains with filtered bottle filler fountains.
    6. Reconfigure and modify the water and sanitary systems at all restrooms being remodeled as part of the architectural scope.
  • Miscellaneous construction requirements.
    1. Repaint all hangar high bay walls, removing and reinstalling bird netting as required. Paint as scheduled in the contract drawings.
    2. Repaint and restripe the Hangar 8 High Bay floors to match existing.
    3. Remove existing RF shielding walls, floors, and ceilings at Hangar 09 3rd floor east and replace with stud and drywall construction, new ceilings, and flooring.
    4. Renovate break room at Hangar 9 3rd floor east located in RF shielded room.

 Market Survey Response should include the following:

1. Capability Statement - This document should identify:
- Type of services provided by firm,
- Size and type of services provided on previous government/private sector contracts 
- Number of years in business
- Small Business Size Status to include applicable socio-economic information such as 8(a), WOSB, SDVSB, etc.

2. Detailed information (Agency or Customer/Dollar Amount/Scope/etc.) regarding past projects respondent has completed with similar work to work identified in this Market Survey.

Respondents must be active in the System for Award Management (SAM) (www.sam.gov).

All responses to this market survey must be received by Friday, September 27th, 2024, 4:00 p.m. CT. All capability statements must be submitted by email to: andre.casiano@faa.gov.

The responses to this market survey will be used for informational and procurement planning purposes only. This is not a screening information request or request for proposal of any kind. The FAA is not seeking or accepting proposals at this time.

The FAA will not pay for any information received or costs incurred in preparing the response to the market survey. Therefore, any cost associated with the market survey submission is solely at the interested vendor's expense.

Notice history

Notice Type Posted
-Award Notice: Solicitation - Hanger 9 Renovation at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK Award Award Notice
Solicitation - Hanger 9 Renovation at the Mike Monroney Aeronautical Center (MMAC), Oklahoma City, OK Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Mechanical Construction Services IDIQ - MMAC Oklahoma City, Oklahoma 73169, United States · NAICS 238220 Franchise Acquisition Servies Total Small Business
Market Survey for Janitorial Services at FAA Facilities in King Salmon, Alaska King Salmon, Alaska, United States · NAICS 561720 Southwestern Region No set-aside
Market Survey for Helicopter Services for the FAA between Juneau and other Sites in Alaska Juneau, Alaska, United States · NAICS 481211 Southwestern Region No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors