H344--Boiler Safety Device Testing Services for the Louis A. Johnson VAMC

Closed Pre-Solicitation Posted

Solicitation number
36C24523Q0921
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Louis A. Johnson VA Medical Center 1 Med Center Drive Clarksburg WV 26301

Notice details come from SAM.gov. Updated .

About this opportunity

The Veterans Health Administration is seeking qualified testing contractors to perform boiler safety device testing services at the Louis A. Johnson VA Medical Center in Clarksburg, West Virginia. The contractor will be responsible for inspection, tuning, testing, calibrating, and adjustments of burners and boiler and boiler plant controls in accordance with various standards and regulations. Responses to this request for information/sources sought notice must be submitted by 11:00 AM Eastern on July 28, 2023.

The services to be provided by the contractor include:

  1. Inspection of burners and boiler and boiler plant controls.
  2. Tuning of burners and boiler and boiler plant controls.
  3. Testing of burners and boiler and boiler plant controls.
  4. Calibration of burners and boiler and boiler plant controls.
  5. Adjustments of burners and boiler and boiler plant controls.

Notice text

Veterans Health Administration, Network Contracting Office 5, is issuing this request for information/sources sought notice in order to identify qualified testing contractors that have the resources and capabilities to perform boiler safety device testing services for the Louis A. Johnson VA Medical Center, located in Clarksburg, West Virginia.

Description of Work

The contractor will provide all tools and labor necessary to perform inspection, tuning, testing, calibrating, and adjustments of burners and boiler and boiler plant controls in accordance with recommendations and requirements of VHA Boiler Plant Safety Devices Testing Manual, the equipment manufacturers, NFPA 85 Boiler and Combustion Systems Hazards Code, and VHA Directive 1810.

Technical Qualifications

Contractor must be a qualified testing contractor i.e., must be an individual/company that has performed testing in compliance with VHA Boiler and Associated Plant Safety Device Testing Manual in at least three other VA medical facilities. Technicians shall have completed at least a one-year trade school and have five years successful experience in this field. The experience shall be largely with institutional and industrial boiler plants.

Interested & Capable Responses

NCO 5 is seeking responses from entities that are interested in this procurement and consider themselves to have the resources and capabilities necessary to provide these services. Please respond with your:

1. Business name, business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), and person of contact (including telephone number & email address).

2. Capability statement and summary of previous experience performing boiler safety device testing services for the Veterans Health Administration.

3. Ballpark cost estimate of what the Louis A. Johnson VAMC could expect to pay your company a year to perform the work described above.

Responses must be submitted by 11:00 AM Eastern on July 28, 2023. Responses to the information requested above must be submitted via email to james.whisner@va.gov.

This request for information/sources sought notice is for planning purposes ONLY. The results of this market research will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice.

Files

File Type Posted
36C24523Q0921.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
J045--Annual Boiler Maintenance RMR VAMC Department of Veterans Affairs Rocky Mountain Regional Vamc Aurora CO 80045, United States · NAICS 238220 Veterans Integrated Service Network 19 No set-aside
J041--Building 2 Steam Station Replacement West Haven Vamc West Haven CT 06516 · NAICS 238220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
H945--Boiler Controls Inspection and Testing NAICS 541350 Veterans Integrated Service Network 10 No set-aside
Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 United States · NAICS 238220 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
J041--Condensate Pump Replacement West Haven Vamc West Haven CT 06516 · NAICS 238220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors