H312--FY26 FIRE EXTINGUISHER TESTING Battle Creek, MI VA Medical Center
Closed Pre-Solicitation Posted
- Solicitation number
- 36C25026Q0865
- Agency
-
Veterans Integrated Service Network 10
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541990 All Other Professional, Scientific, and Technical Services
- PSC
- H312 Inspection- Fire Control Equipment
- Place of performance
- Department of Veterans Affairs Battle Creek VA Medical Center Battle Creek MI 49037, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
Veterans Integrated Service Network 10 is issuing a sources sought notice (RFI) for fire extinguisher testing and inspection services at Battle Creek VA Medical Center in Battle Creek, Michigan, with responses due August 18, 2026.
This is market research only and carries no set-aside. Work involves NFPA 10 certified technician services on 71 total fire extinguishers: 36 ten-pound ABC units requiring hydrotesting, 32 ten-pound ABC units requiring six-year testing, and 3 twenty-pound ABC units requiring hydrotesting. Scope also includes recharging, annual inspection tag installation, and documentation through a web-based Building Reports system.
The contractor must schedule work to begin no later than 30 days after award and complete all services within 14 calendar days. Work is performed on-site at the VA Medical Center during normal business hours (7:00 AM to 4:00 PM, Monday through Friday). The Government will not furnish equipment or materials; the contractor provides all labor, tools, parts, and materials. The contractor must maintain 24-hour response times on business days and coordinate with the Contracting Officer's Representative.
Respondents should submit company name, address, point of contact, phone number, and e-mail address; small business certification status across available programs (SB, HUBZone, 8(a), SDB, WO, SDVOSB, VOSB); and a capability statement not to exceed five pages. Commercial brochures or existing marketing material may be included. Responses go to timothy.garrity@va.gov. NAICS code 541990; PSC H312.
Notice text
This is a request for information (RFI) notice for market research purposes only to determine the availability of potential businesses with capabilities to provide the services described below. Potential offerors are invited to provide feedback via e-mail to timothy.garrity@va.gov. Responses will be used to determine the appropriate acquisition strategy for a potential future acquisition.
Potential contractors shall provide, at a minimum, the following:
1) Company name, address, point of contact, phone number, and e-mail address.
2) Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program. Anticipated North American Industry Classification System (NAICS) code is 541990 and Product Service Code (PSC) H312
[ ] yes [ ] no Small Business (SB)
[ ] yes [ ] no HUBZone
[ ] yes [ ] no Small Business 8(a)
[ ] yes [ ] no Small Disadvantaged Business (SDB)
[ ] yes [ ] no Women-Owned (WO) Small Business
[ ] yes [ ] no Service-Disabled Veteran Owned Small Business (SDVOSB)
[ ] yes [ ] no Veteran Owned Small Business (VOSB)
[ ] yes [ ] no Other (please specify)
[ ] yes [ ] no GSA/Federal Supply Schedule contract
3) Provide a brief capability statement (Max 5 pages) with enough information to determine if your company can meet the requirements. The capabilities statement for this sources sought is not expected to be a Request for Quotation, Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather the Government is requesting a short statement regarding the company s ability to provide the services outlined in the draft statement of work below. Any commercial brochures or currently existing marketing material may also be submitted with the capabilities statement. This synopsis is for information and planning purposes only and is not to be construed as a commitment by the Government. The Government will not pay for information solicited. Respondents will not be notified of the results of the evaluation.
The Department of Veterans Affairs, Battle Creek, IN., Health Care System located at 5500 Armstrong Road, Battle Creek, MI 49037, intends to award a contract for the testing and inspection on all fire extinguishers, in accordance with the Statement of Work (SOW).
STATEMENT OF WORK
SOW Title: Battle Creek Fire Extinguisher Testing and Inspection Services FY26
Background: The Battle Creek VA Medical Center is required to complete testing and inspection on all fire extinguishers as established by the National Fire Protection Association (NFPA) Codes and Standards NFPA 10 Standard for Portable Fire Extinguishers.
Scope: The Veterans Affairs, Network Contracting Office (NCO) 10, requires a contract to complete testing and inspection on all fire extinguishers at the Battle Creek VA Medical Center, located at 5500 Armstrong Rd, Battle Creek, MI, in accordance with NFPA 10. Services shall be in accordance with the terms, conditions, provisions and schedule of the contract.
Specific Tasks
The contractor shall provide an NFPA 10 certified technician to perform this work.
Contractor shall provide all supervision, labor, tools, parts, and materials to perform all-inclusive six (6) year inspection, and hydro/testing for fire extinguishers at the Battle Creek VA Medical Center.
In accordance with NFPA 10 and any other applicable regulations the contractor shall provide testing of the following equipment:
10lb. ABC Hydrotesting on a quantity of 36 fire extinguishers.
10lb. ABC 6-year testing on a quantity of 32 fire extinguishers.
20lb. ABC Hydrotesting on a quantity of 3 fire extinguishers.
The contractor shall perform recharging and hydrostatic testing on the equipment and in quantities specified herein. If it is discovered that additional fire extinguishers require charging, hydrostatic testing or other servicing, the contractor shall immediately notify the COR and if approved the Contracting Officer will issue a modification to perform the work. The Contractor shall not perform additional work until the modification is executed.
The contractor shall furnish and install annual inspection tags for the fire extinguishers.
The contractor shall perform all testing/inspections on site at the Battle Creek VA Medical Center.
General Requirements
The Contracting Officer s Representative (COR) shall provide the contractor with a printout of all fire extinguishers and locations.
The Contractor shall schedule this work with the COR at least five (5) calendar days in advance. The Contractor shall schedule initial work to begin no later than 30 calendar days after award and once work is initiated, work shall be completed within 14 calendar days.
All on-site work shall be coordinated with the COR.
The contractor shall respond to routine communications within 24 hours on business days and 48 hours on holidays/weekends.
Normal business hours are 7:00 a.m. to 4:00 p.m., Monday through Friday excluding the following federal holidays: New Year's Day, Birthday of Martin Luther King, Jr, Washington s Birthday, Memorial Day, Juneteenth National Independence Day, Independence Day, Labor Day, Columbus Day, Veterans Day, Thanksgiving Day, Christmas Day, and any other day specifically declared by the President of the United States to be a national holiday.
Deliverables
The contractor shall document all testing and inspection activities through a web-based service called Building Reports.
Contractor will inform COR when testing and inspection documentation is complete.
Security Requirements:
Contractors will not have access to VA Sensitive Information, patient records, or data.
All Contractor personnel are required to wear identification (ID) badges during the entire period during which they are on VA grounds. ID badges must show an identification picture, name of the individual, and the represented company.
Performance: The Government reserves the right to document performance. Any report created in relation to this requirement will become a part of the supporting documentation for any contractual action.
Government-Furnished Equipment (GFE)/Government-Furnished Information (GFI): The Battle Creek VA Medical Center will not furnish parts and/or test equipment for the performance of this contract. It is the responsibility of the contractor to bring the appropriate equipment; and/or supplies necessary to complete the work as required in this contract.
Files
| File | Type | Posted |
|---|---|---|
| 36C25026Q0865.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 36C26127Q0086, Fire Extinguisher Inspection and Maintenance Services | Veterans Integrated Service Network 21 | Service-Disabled Veteran-Owned Small Business | |
| Fire extinguisher inspection, maintenance, recharge, repair, hydrostatic testing | Army National Guard | No set-aside | |
| H212--Annual Test/Inspection of FireFly Device and Door Drop Cleveland VA Medical Center | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| J042--Fire Alarm, Suppression Systems, and Hood Testing, Inspection, and Certification Services - SAVAHCS | Veterans Integrated Service Network 22 | Service-Disabled Veteran-Owned Small Business | |
| H212-- Fire Pump Test and Alarm support | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity