GC26 fire alarm system replacement
Closed Pre-Solicitation Posted
Not the latest version. See the latest solicitation from .
- Solicitation number
- 140R4026R0010
- Agency
-
Bureau of Reclamation
Department of the Interior
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Interior Bureau of Reclamation is seeking qualified contractors to remove, dispose of, and replace existing fire detection and alarm systems at Glen Canyon Powerplant and associated facilities located approximately 3 miles northwest of Page, Arizona. The scope of work includes designing, furnishing, and installing new fire detection and alarm systems at three locations: Glen Canyon Powerplant, Carl Hayden Visitor Center, and Facility Workshop Building, as well as installing a hybrid water mist fire suppression system in the powerplant computer room. Contractors must demonstrate relevant experience with similar fire alarm and suppression system projects and must possess the capability to integrate the new systems with existing elevators, stairwell pressurization, generator CO release, transformer deluge, and HVAC systems. Respondents to this Sources Sought Notice must provide company name, address, point of contact, Unique Entity ID, business size classification, and a capability statement demonstrating their ability to perform the work. This is a pre-solicitation notice for market research purposes only with a response deadline of March 10, 2026, and it is not yet a formal solicitation for proposals or quotations.
This contract opportunity is designated as a Total Small Business set-aside, with the NAICS code 238210 (Electrical Contractors and Other Wiring Installation Contractors) applicable and a corresponding business size standard of $19.0 million. No incumbent contractor or specific award value has been identified in this pre-solicitation notice. The project requires contractors to plan and sequence work to eliminate or minimize interruptions to critical station loads within the plant, as well as test and commission all systems upon completion. Key work components include removing existing interconnection wiring, modifying 120-volt distribution systems, providing a laptop computer compatible with the new system, and integrating alarm signals from fire alarm panels at multiple facility locations. Interested contractors should use this pre-solicitation period to assess their qualifications and prepare for the upcoming formal solicitation.
Notice text
GC26 FIRE ALARM SYSTEM REPLACEMENT
Sources Sought Notice
Fire Detection and Alarm System Upgrade ¿ Glen Canyon Powerplant and Associated Facilities
This is a Sources Sought Notice for market research purposes only. The Government is seeking qualified and capable contractors to perform the following work. This is NOT a solicitation for proposals or quotations.
Project Location:
Glen Canyon Powerplant, approximately 3 miles northwest of Page, Arizona, in Coconino County.
Principal Components of Work:
¿ Remove, dispose of, and replace existing fire detection and alarm systems.
¿ Remove existing interconnection wiring for the fire detection and alarm system.
¿ Design, furnish, and install a new fire detection and alarm system at three locations: Glen Canyon Powerplant, Carl Hayden Visitor Center, and Facility Workshop Building.
¿ Provide a new laptop computer compatible with and able to operate and monitor the system.
¿ Communicate and integrate alarm signals from fire alarm panels at the Government Project Warehouse Building, Carl Hayden Visitor Center, and Facility Workshop.
¿ Design, furnish, and install a hybrid water mist fire suppression system in the powerplant computer room.
¿ Modify 120-volt distribution systems to accommodate new fire detection and alarm equipment.
¿ Integrate new fire alarm system with existing elevators, stairwell pressurization system, generator CO¿ release system, transformer deluge system, and HVAC systems.
¿ Test and commission all systems.
¿ Plan and sequence work to eliminate or minimize interruptions of service to critical station loads within the plant.
NAICS Code:
238210 ¿ Electrical Contractors and Other Wiring Installation Contractors (verify applicability). Business size standard is $19.0M
Response Requirements:
¿ Company name, address, and point of contact
¿ Unique Entity ID
¿ Business size (Small Business, 8(a), HUBZone, SDVOSB, etc.)
¿ Relevant experience with similar fire alarm and suppression system projects
¿ Capability statement demonstrating ability to perform the work
¿ Applicable certifications (e.g., NICET, manufacturer certifications)
¿ Registered in SAM.gov (yes/no)
¿ Recommended North American Industry Code (NAICS CODE) if other the 238210.
Submission Deadline:
Please provide the responses to this source sought by March 10st 2026. Questions regarding this source sought shall be directed to Lisa Laughbon Contract Specialist at llaughbon@usabr.gov
Disclaimer:
This notice is for planning purposes only and does not commit the Government to any contractual action.
Notice history
| Notice | Type | Posted |
|---|---|---|
| GC26 fire alarm system replacement | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Fire alarm replacement IDIQ | Office of Acquisition Management | Total Small Business | |
| Fire Alarm/Suppression Inspection, Testing, and Maintenance | Air Force Research Laboratory | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity