Electrical connection of water chillers

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
140G0225Q0077
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Notice details come from SAM.gov. Updated .

About this opportunity

The US Geological Survey Office of Acquisitions and Grants is seeking electrical connection services for two industrial water chillers at the Tunison Laboratory of Aquatic Science in Cortland, New York. The project requires a licensed electrician to install dedicated 208V 3-phase electrical circuits running approximately 145 feet from the laboratory's electrical panel to the external chiller location, including circuit breakers, electrical cable, conduit, safety disconnect switches, and proper grounding and testing. Contractors must provide proof of current OSHA Safety Certificate, Electrical Technician Certification, EPA Amusement Operators Safety Certification, and demonstrate similar project experience within the last three years. The contract will be awarded to the lowest-priced, technically acceptable offeror under a firm fixed-price arrangement. A mandatory site visit is scheduled for June 27, 2025 at 10:00 AM EST, with the proposal due date extended to July 2, 2025 at 12:00 PM MDT, and quotations must be submitted via email to Philip Robinson.

This solicitation does not utilize any set-aside designation and is open to all qualified contractors. No incumbent contractors or current service providers are identified in the documentation. While specific contract values are not disclosed, the scope involves connecting two industrial-grade water chillers with electrical specifications of 208/230V, 3-phase, 143 FLA, 178 MCA, and 250 MOP. The performance period is established as July 15, 2025 through August 14, 2025, providing a 30-day window for completion. All work will be performed at the USGS Tunison Laboratory of Aquatic Science located at 3075 Gracie Road in Cortland, New York, with electrical connections required to run through the laboratory attic to reach the chillers' external location.

Notice text

3 versions

Update #3 · Latest ·

ELECTRICAL CONNECTION OF WATER CHILLERS - Amendment 0002

Update #2 ·

ELECTRICAL CONNECTION OF WATER CHILLERS - Amendment 0001

Update #1 ·

ELECTRICAL CONNECTION OF WATER CHILLERS

Files

Notice history

Notice Type Posted
Electrical connection of water chillers Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Refurbishment of Existing Tree Cooler, St. Joe Ranger District, Idaho Panhandle National Forests Idaho 83802, United States · NAICS 811310 Forest Service Total Small Business
Cooling Tower, Roofing, and Structural Construction District of Columbia 20024, United States · NAICS 236220 Bureau of Engraving and Printing Total Small Business
Electrical Upgrades to the GCAFB/Tanker Base/Fire Cache Hurley, New Mexico 88043, United States · NAICS 238210 Forest Service Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors