Electrical connection of water chillers
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 140G0225Q0077
- Agency
-
Office of Acquisitions and Grants
US Geological Survey, Department of the Interior
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The US Geological Survey Office of Acquisitions and Grants is seeking electrical connection services for two industrial water chillers at the Tunison Laboratory of Aquatic Science in Cortland, New York. The project requires a licensed electrician to install dedicated 208V 3-phase electrical circuits running approximately 145 feet from the laboratory's electrical panel to the external chiller location, including circuit breakers, electrical cable, conduit, safety disconnect switches, and proper grounding and testing. Contractors must provide proof of current OSHA Safety Certificate, Electrical Technician Certification, EPA Amusement Operators Safety Certification, and demonstrate similar project experience within the last three years. The contract will be awarded to the lowest-priced, technically acceptable offeror under a firm fixed-price arrangement. A mandatory site visit is scheduled for June 27, 2025 at 10:00 AM EST, with the proposal due date extended to July 2, 2025 at 12:00 PM MDT, and quotations must be submitted via email to Philip Robinson.
This solicitation does not utilize any set-aside designation and is open to all qualified contractors. No incumbent contractors or current service providers are identified in the documentation. While specific contract values are not disclosed, the scope involves connecting two industrial-grade water chillers with electrical specifications of 208/230V, 3-phase, 143 FLA, 178 MCA, and 250 MOP. The performance period is established as July 15, 2025 through August 14, 2025, providing a 30-day window for completion. All work will be performed at the USGS Tunison Laboratory of Aquatic Science located at 3075 Gracie Road in Cortland, New York, with electrical connections required to run through the laboratory attic to reach the chillers' external location.
Notice text
3 versions
Update #3 · Latest ·
ELECTRICAL CONNECTION OF WATER CHILLERS - Amendment 0002
Update #2 ·
ELECTRICAL CONNECTION OF WATER CHILLERS - Amendment 0001
Update #1 ·
ELECTRICAL CONNECTION OF WATER CHILLERS
Files
Notice history
| Notice | Type | Posted |
|---|---|---|
| Electrical connection of water chillers | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| EROS Removal and replacement of chilled and conden | — | Total Small Business | |
| Remove and Replace Walkin Cooler and Freezer | — | Total Small Business | |
| NSWCCD York Chill Pump Replacement | Naval Sea Systems Command | No set-aside | |
| Fernan Ranger Station lift station electrical repair | Region 1 - Northern Region | Total Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity