The Defense Logistics Agency (DLA) is soliciting quotes for parking lot repair services at the Defense Supply Center Richmond (DSCR) facility through Request for Quote (RFQ) SP4703-26-Q-0027, issued under FAR Part 12 procedures. The project requires contractors to remove an existing temporary gravel parking area and construct approximately 3,500 square feet of permanent pavement infrastructure, including eight standard parking stalls with a 24-foot-wide driving aisle, a concrete sidewalk section with appropriate ramps, and a minimum of two exterior lighting fixtures complying with Department of Defense standards. Key contract requirements include contractors demonstrating a minimum of five years' experience in concrete and parking lot construction, possessing relevant certifications, ensuring all personnel are OSHA-certified and trained in federal environmental compliance, maintaining valid insurance coverage, obtaining base access clearance, and adhering to DSCR security protocols. Award will be made to the lowest priced, technically acceptable (LPTA) offeror, with past performance evaluated through CPARS and SPRS data as part of the technical acceptability assessment. The deadline for submitting questions is March 31, 2026 at end of day, and quotes are due by April 7, 2026 at end of day, with a site visit offered on March 25, 2026 at 13:00.

This acquisition is set aside for 100% small businesses under NAICS Code 237310 (Parking Lot Repair), with a small business size standard of $45 million. The resulting contract will be a firm-fixed-price award with an expected period of performance of 60 days from contract issuance, with the completion date no later than 60 days after notice to proceed. Contractors must be registered in the System for Award Management (SAM) prior to award and must be located within a 120-mile radius of DSCR, with the point of mobilization required to be a location owned by the prime contractor. The work will be performed at DSCR located at 6090 Strathmore Road, North Chesterfield, Richmond, Virginia 23236, with Robert Miller serving as the project manager and contracting officer representative. Department of Labor prevailing wage rates apply based on the location of service provision in Richmond, Virginia.

Notice text

4 versions

Update #4 · Latest ·

RFI's: 

1. Material Specification

The required material for the 4" open-graded drainage layer should be a hard, durable, crushed aggregate that meets the gradation for a Rapid Draining Material (RDM) or Open Graded Material (OGM) as specified in UFC 3-250-01, Chapter 20. The material must provide sufficient stability for construction equipment and have a minimum permeability of 1,000 ft/day.

2. Compaction Requirements

This layer must be compacted. Per UFC 3-250-01, Appendix B, compaction of drainage layers is achieved with a specified effort, in this case, six passes of a 10-ton vibratory roller, rather than a final density percentage. This ensures the aggregate is stable without crushing it, which would reduce its permeability.

3. Additional Installation Requirements

Based on UFC 3-250-01, the following additional requirements apply:

  • Separation Layer: A granular separation layer (minimum 50 CBR) or an approved geotextile fabric must be placed directly beneath the drainage layer to prevent contamination from the subgrade. 
  • Placement: The aggregate should be placed to ensure uniform thickness and prevent segregation. It should be placed on the prepared VDOT 21A subbase to a compacted thickness of 4 inches. 
  • Protection: The completed drainage layer must be protected from contamination and disturbance. The subsequent pavement layer should be placed as soon as possible.

4. Gazebo - DLA will move the gazebo before work commences. The contractor is not responisble for this action. 

---------------------------------------

Update 30 March 2026:

Typos identified. The CORRECT timing for this RFQ is: 

Questions: 31 March 2026, end of day

Quotes Due: 7 April 2026, end of day. 

---------------------------------------

Solicitation

Defense Supply Center Richmond (DSCR) B41 Parking Lot Repair

This is a solicitation for services prepared in accordance with the format in FAR Part 12, as supplemented with additional information included in this notice.  The solicitation number SP4703-26-Q-0027 is issued as a request for quote (RFQ).  The resulting contract will be a firm-fixed price award with an expected Period of Performance of 60 days from the issuance of the contract award. This acquisition is set-aside for 100% small businesses.  The North American Industry Classification System (NAICS) Code is 237310 (Parking Lot Repair).  The small business size standard is $45M.  Department of Labor Wage Determination based on location of the service provided (Richmond, VA).  Partial proposals will not be accepted. 

For an offer to be considered for award, the contractor must be within a commutable driving distance to the DSCR facility. The point of mobilization must be annotated on the quote, and must be a location owned by the prime contractor, not a subcontractor. A 120-mile radius from DSCR is considered the commutable radius for this project.

Award will be made to the lowest priced, technically acceptable (LPTA) offeror that meets the requirements stated in the Statement of Work and the solicitation. Also refer to clauses and provisions includes in this notice.  Past performance will be considered a part of Technical Acceptability, and the Contracting Officer will pull contractor data from CPARS and SPRS.

                                                     

The contractor must be registered in the System for Award Management (SAM) prior to award.  If not already registered in SAM, go to the SAM website www.sam.gov to register prior to submitting your quote. 

All inquiries must be submitted no later than 7 business days prior to closing date.  Acceptable method of quote or inquiries submission is Email to brandon.jump@dla.mil.

Site visit March 25, 2026 at 13:00. Coordinate site access with Robert Miller at Robert.C.Miller@dla.mil. Meeting point is the DSCR Visitor’s Center unless instructed otherwise.

Questions are due on March 31, 2026, end of day. Submit questions via email to Brandon.Jump@dla.mil.

Quotes are due April 7, 2026, end of day.  

Access to Defense Supply Center Richmond is dictated by the language at the following location:

https://www.dla.mil/Aviation/Installation/Visitors-and-ID-Office/

The points of contact (POC) for this requirement are Brandon Jump (brandon.jump@dla.mil).

Reference Attachment 1 - Statement of Work (SOW) for additional work scope and details. Use the site map on the last page of the SOW.

MAGINITUDE OF CONSTRUCTION

36.204 Disclosure of the magnitude of construction projects. | Acquisition.GOV

In accordance with FAR Part 36.204(b), the estimated Magnitude of Construction for requirement is between $25,000 and $100,000.

LIQUIDATED DAMAGES

52.211-12 Liquidated Damages-Construction.

LIQUIDATED DAMAGES-CONSTRUCTION (SEPT 2000)

(a) If the Contractor fails to complete the work within the time specified in the contract, the Contractor shall pay liquidated damages to the Government in the amount of _$500_ for each calendar day of delay until the work is completed or accepted.

(b) If the Government terminates the Contractor’s right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.

Update #3 ·

RFI's: 

1. Material Specification

The required material for the 4" open-graded drainage layer should be a hard, durable, crushed aggregate that meets the gradation for a Rapid Draining Material (RDM) or Open Graded Material (OGM) as specified in UFC 3-250-01, Chapter 20. The material must provide sufficient stability for construction equipment and have a minimum permeability of 1,000 ft/day.

2. Compaction Requirements

This layer must be compacted. Per UFC 3-250-01, Appendix B, compaction of drainage layers is achieved with a specified effort, in this case, six passes of a 10-ton vibratory roller, rather than a final density percentage. This ensures the aggregate is stable without crushing it, which would reduce its permeability.

3. Additional Installation Requirements

Based on UFC 3-250-01, the following additional requirements apply:

  • Separation Layer: A granular separation layer (minimum 50 CBR) or an approved geotextile fabric must be placed directly beneath the drainage layer to prevent contamination from the subgrade. 
  • Placement: The aggregate should be placed to ensure uniform thickness and prevent segregation. It should be placed on the prepared VDOT 21A subbase to a compacted thickness of 4 inches. 
  • Protection: The completed drainage layer must be protected from contamination and disturbance. The subsequent pavement layer should be placed as soon as possible.

---------------------------------------

Update 30 March 2026:

Typos identified. The CORRECT timing for this RFQ is: 

Questions: 31 March 2026, end of day

Quotes Due: 7 April 2026, end of day. 

---------------------------------------

Solicitation

Defense Supply Center Richmond (DSCR) B41 Parking Lot Repair

This is a solicitation for services prepared in accordance with the format in FAR Part 12, as supplemented with additional information included in this notice.  The solicitation number SP4703-26-Q-0027 is issued as a request for quote (RFQ).  The resulting contract will be a firm-fixed price award with an expected Period of Performance of 60 days from the issuance of the contract award. This acquisition is set-aside for 100% small businesses.  The North American Industry Classification System (NAICS) Code is 237310 (Parking Lot Repair).  The small business size standard is $45M.  Department of Labor Wage Determination based on location of the service provided (Richmond, VA).  Partial proposals will not be accepted. 

For an offer to be considered for award, the contractor must be within a commutable driving distance to the DSCR facility. The point of mobilization must be annotated on the quote, and must be a location owned by the prime contractor, not a subcontractor. A 120-mile radius from DSCR is considered the commutable radius for this project.

Award will be made to the lowest priced, technically acceptable (LPTA) offeror that meets the requirements stated in the Statement of Work and the solicitation. Also refer to clauses and provisions includes in this notice.  Past performance will be considered a part of Technical Acceptability, and the Contracting Officer will pull contractor data from CPARS and SPRS.

                                                     

The contractor must be registered in the System for Award Management (SAM) prior to award.  If not already registered in SAM, go to the SAM website www.sam.gov to register prior to submitting your quote. 

All inquiries must be submitted no later than 7 business days prior to closing date.  Acceptable method of quote or inquiries submission is Email to brandon.jump@dla.mil.

Site visit March 25, 2026 at 13:00. Coordinate site access with Robert Miller at Robert.C.Miller@dla.mil. Meeting point is the DSCR Visitor’s Center unless instructed otherwise.

Questions are due on March 31, 2026, end of day. Submit questions via email to Brandon.Jump@dla.mil.

Quotes are due April 7, 2026, end of day.  

Access to Defense Supply Center Richmond is dictated by the language at the following location:

https://www.dla.mil/Aviation/Installation/Visitors-and-ID-Office/

The points of contact (POC) for this requirement are Brandon Jump (brandon.jump@dla.mil).

Reference Attachment 1 - Statement of Work (SOW) for additional work scope and details. Use the site map on the last page of the SOW.

MAGINITUDE OF CONSTRUCTION

36.204 Disclosure of the magnitude of construction projects. | Acquisition.GOV

In accordance with FAR Part 36.204(b), the estimated Magnitude of Construction for requirement is between $25,000 and $100,000.

LIQUIDATED DAMAGES

52.211-12 Liquidated Damages-Construction.

LIQUIDATED DAMAGES-CONSTRUCTION (SEPT 2000)

(a) If the Contractor fails to complete the work within the time specified in the contract, the Contractor shall pay liquidated damages to the Government in the amount of _$500_ for each calendar day of delay until the work is completed or accepted.

(b) If the Government terminates the Contractor’s right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.

Update #2 ·

Update 30 March 2026:

Typos identified. The CORRECT timing for this RFQ is: 

Questions: 31 March 2026, end of day

Quotes Due: 7 April 2026, end of day. 

---------------------------------------

Solicitation

Defense Supply Center Richmond (DSCR) B41 Parking Lot Repair

This is a solicitation for services prepared in accordance with the format in FAR Part 12, as supplemented with additional information included in this notice.  The solicitation number SP4703-26-Q-0027 is issued as a request for quote (RFQ).  The resulting contract will be a firm-fixed price award with an expected Period of Performance of 60 days from the issuance of the contract award. This acquisition is set-aside for 100% small businesses.  The North American Industry Classification System (NAICS) Code is 237310 (Parking Lot Repair).  The small business size standard is $45M.  Department of Labor Wage Determination based on location of the service provided (Richmond, VA).  Partial proposals will not be accepted. 

For an offer to be considered for award, the contractor must be within a commutable driving distance to the DSCR facility. The point of mobilization must be annotated on the quote, and must be a location owned by the prime contractor, not a subcontractor. A 120-mile radius from DSCR is considered the commutable radius for this project.

Award will be made to the lowest priced, technically acceptable (LPTA) offeror that meets the requirements stated in the Statement of Work and the solicitation. Also refer to clauses and provisions includes in this notice.  Past performance will be considered a part of Technical Acceptability, and the Contracting Officer will pull contractor data from CPARS and SPRS.

                                                     

The contractor must be registered in the System for Award Management (SAM) prior to award.  If not already registered in SAM, go to the SAM website www.sam.gov to register prior to submitting your quote. 

All inquiries must be submitted no later than 7 business days prior to closing date.  Acceptable method of quote or inquiries submission is Email to brandon.jump@dla.mil.

Site visit March 25, 2026 at 13:00. Coordinate site access with Robert Miller at Robert.C.Miller@dla.mil. Meeting point is the DSCR Visitor’s Center unless instructed otherwise.

Questions are due on March 31, 2026, end of day. Submit questions via email to Brandon.Jump@dla.mil.

Quotes are due April 7, 2026, end of day.  

Access to Defense Supply Center Richmond is dictated by the language at the following location:

https://www.dla.mil/Aviation/Installation/Visitors-and-ID-Office/

The points of contact (POC) for this requirement are Brandon Jump (brandon.jump@dla.mil).

Reference Attachment 1 - Statement of Work (SOW) for additional work scope and details. Use the site map on the last page of the SOW.

MAGINITUDE OF CONSTRUCTION

36.204 Disclosure of the magnitude of construction projects. | Acquisition.GOV

In accordance with FAR Part 36.204(b), the estimated Magnitude of Construction for requirement is between $25,000 and $100,000.

LIQUIDATED DAMAGES

52.211-12 Liquidated Damages-Construction.

LIQUIDATED DAMAGES-CONSTRUCTION (SEPT 2000)

(a) If the Contractor fails to complete the work within the time specified in the contract, the Contractor shall pay liquidated damages to the Government in the amount of _$500_ for each calendar day of delay until the work is completed or accepted.

(b) If the Government terminates the Contractor’s right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.

Update #1 ·

Solicitation

Defense Supply Center Richmond (DSCR) B41 Parking Lot Repair

This is a solicitation for services prepared in accordance with the format in FAR Part 12, as supplemented with additional information included in this notice.  The solicitation number SP4703-26-Q-0027 is issued as a request for quote (RFQ).  The resulting contract will be a firm-fixed price award with an expected Period of Performance of 60 days from the issuance of the contract award. This acquisition is set-aside for 100% small businesses.  The North American Industry Classification System (NAICS) Code is 237310 (Parking Lot Repair).  The small business size standard is $45M.  Department of Labor Wage Determination based on location of the service provided (Richmond, VA).  Partial proposals will not be accepted. 

For an offer to be considered for award, the contractor must be within a commutable driving distance to the DSCR facility. The point of mobilization must be annotated on the quote, and must be a location owned by the prime contractor, not a subcontractor. A 120-mile radius from DSCR is considered the commutable radius for this project.

Award will be made to the lowest priced, technically acceptable (LPTA) offeror that meets the requirements stated in the Statement of Work and the solicitation. Also refer to clauses and provisions includes in this notice.  Past performance will be considered a part of Technical Acceptability, and the Contracting Officer will pull contractor data from CPARS and SPRS.

                                                     

The contractor must be registered in the System for Award Management (SAM) prior to award.  If not already registered in SAM, go to the SAM website www.sam.gov to register prior to submitting your quote. 

All inquiries must be submitted no later than 7 business days prior to closing date.  Acceptable method of quote or inquiries submission is Email to brandon.jump@dla.mil.

Site visit March 25, 2026 at 13:00. Coordinate site access with Robert Miller at Robert.C.Miller@dla.mil. Meeting point is the DSCR Visitor’s Center unless instructed otherwise.

Questions are due on March 31, 2026, end of day. Submit questions via email to Brandon.Jump@dla.mil.

Quotes are due April 7, 2026, end of day.  

Access to Defense Supply Center Richmond is dictated by the language at the following location:

https://www.dla.mil/Aviation/Installation/Visitors-and-ID-Office/

The points of contact (POC) for this requirement are Brandon Jump (brandon.jump@dla.mil).

Reference Attachment 1 - Statement of Work (SOW) for additional work scope and details. Use the site map on the last page of the SOW.

MAGINITUDE OF CONSTRUCTION

36.204 Disclosure of the magnitude of construction projects. | Acquisition.GOV

In accordance with FAR Part 36.204(b), the estimated Magnitude of Construction for requirement is between $25,000 and $100,000.

LIQUIDATED DAMAGES

52.211-12 Liquidated Damages-Construction.

LIQUIDATED DAMAGES-CONSTRUCTION (SEPT 2000)

(a) If the Contractor fails to complete the work within the time specified in the contract, the Contractor shall pay liquidated damages to the Government in the amount of _$500_ for each calendar day of delay until the work is completed or accepted.

(b) If the Government terminates the Contractor’s right to proceed, liquidated damages will continue to accrue until the work is completed. These liquidated damages are in addition to excess costs of repurchase under the Termination clause.

Files

File Type Posted
SF1442_SP470326Q0027.pdf PDF
Attachment 2 - Wage Determination (HWY).pdf PDF
Attachment 1 - SOW.pdf PDF

Notice history

Notice Type Posted
This notice Latest solicitation Solicitation
DSCR B41 Parking Lot Repair Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Loading dock concrete repairs Richmond, Virginia 23249, United States · NAICS 238110 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
Z1DA--528A5-27-504 Seal and Stripe Parking Lots NAICS 236220 Veterans Integrated Service Network 2 No set-aside
Z2DA--FY27 NRM - 36C26126Q1261 | Re-slurry and Re-stripe Bldg. 88 and 98 Parking Lots NAICS 236220 Veterans Integrated Service Network 21 No set-aside
Administrative Parking Lot Repairs Colorado 80526, United States · NAICS 237310 Forest Service Total Small Business
DSCR B34 & B42 System Smoke Testing & Hydro Jetting Richmond, Virginia, United States · NAICS 236220 Defense Logistics Agency Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors