CGC biscayne BAY water mist fire suppression inspection

Closed Solicitation Posted

Solicitation number
70Z8526Q024276
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
336611 Ship Building and Repairing
Place of performance
Saint Ignace, Michigan 49781, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Homeland Security US Coast Guard seeks annual inspection of a Hi-Fog water mist fire suppression system aboard CGC Biscayne Bay, with proposals due May 15 and performance scheduled May 25–28. The procurement is set aside for Total Small Business.

Place of performance is St. Ignace, Michigan. The contractor must hold HI-FOG certification as a technician. Work scope includes system setup for testing, completion of the full water mist system test, return of the system to normal operation, and verification that all connections, fittings, and equipment operate correctly using MPC R-A-13380 as guidance. The contractor is authorized to perform minor adjustments and tuning to restore the system to normal operation only if such work requires no new parts and incurs no additional labor costs. Any discrepancy requiring new parts or labor beyond standard annual inspection scope must be documented in the Final Service Report; the contractor shall not proceed with repairs, which require sole Contracting Officer authorization. The affected equipment MPCs are R-A-13380, R-M-13373, and R-C-14526. The Government Technical Point of Contact is CWO-2 Shane Witko at Shane.d.witko@uscg.mil or 958-285-2047. NAICS is 336611, Ship Building and Repairing; PSC is J020, Maint/Repair/Rebuild Of Equipment – Ship and Marine Equipment.

Notice text

STATEMENT OF WORK

CGC BISCAYNE BAY                                    OPFAC: 17504         LOCATION:  ST IGNACE, MI 

EQUIPMENT:  Hi-Fog Water Mist Fire Suppression System

COMPONENT AFFECTED:  ANNUAL INSPECTION OF SYSTEM

MPC: R-A-13380, R-M-13373, R-C-14526

Contractor must be HI-FOG certified Technician. Contractor must set up water mist system for testing; complete the water mist system test; and place water mist system back in normal operation once test is completed. Contractor must ensure all connections, fittings, and equipment within the water mist system are operating correctly as well. Contractor shall use MPC R-A-13380 as guidance.

The contractor is authorized to perform minor adjustments and tuning as required to restore the system to normal operation, provided these actions do not require any new parts or incur any additional labor costs.

Any discrepancy found that requires new parts or significant labor beyond the scope of a standard annual inspection shall be documented in the Final Service Report. The contractor shall not proceed with any repairs. The Government Technical Point of Contact (TPOC) will route the report to the Contracting Officer, who is the sole authority for authorizing any work that results in additional cost.

POP: 25MAY26-28MAY26

LOCATION/POC:

Witko, Shane CWO-2 USCG CGC BISCAYNE BAY (USA) Shane.d.witko@uscg.mil

Address:

CGC BISCAYNE BAY WTGB (104)
1075 HURON ST
ST IGNACE, MI 49781-0000

958-285-2047

Files

File Type Posted
25023-BISCAYNE BAY-SOW FOR ANNUAL WATER MIST INSPECTION_edits.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Firefighting protection system maintenance Alameda, California 94501, United States · NAICS 336611 — No set-aside
FM 200 Charleston, South Carolina, United States · NAICS 336611 Coast Guard Total Small Business
Fire Protection Services at USCG Air Station Sacramento McClellan, California 95652, United States · NAICS 561621 — No set-aside
Dock-side (DS): USCGC WAESCHE Quarter 2 FY27 Repair Alameda, California, United States · NAICS 336611 — No set-aside
Drydock Repairs USCGC HATCHET (WLIC-75309) NAICS 33661 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity