Carbon Monoxide Detection System, Columbus AFB
Closed Solicitation Posted
A newer solicitation was posted. See the latest solicitation from .
- Solicitation number
- FA302225Q0332
- Agency
- Air Education and Training Command Air Force, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 334290 Other Communications Equipment Manufacturing
- Place of performance
- Columbus, Mississippi 39710, United States
- Points of contact
-
- Logan T. Snodgrass logan.snodgrass@us.af.mil (662) 434-3138
- Joseph Besko joseph.besko@us.af.mil (850) 884-2083
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Air Force Air Education and Training Command is procuring a comprehensive 7-point Carbon Monoxide Detection System for the 14th Security Forces Squadron's indoor firing range at Columbus Air Force Base, Mississippi. The system must include central monitoring capabilities with 87 digital and 12 analog inputs, power supply, alert beacon with audible horn and blue light strobe, wall-mounted fixed gas detectors operating in the 0-200 PPM range, module bus adapter, calibration kit, and CO cylinder. The contractor must supply, deliver, install, test, and provide training to 14 SFS personnel on system operation and maintenance. The evaluation will focus on technical acceptability and price, with technical and past performance having greater importance than cost considerations. Critical dates include questions due September 15, 2025, and proposals due September 19, 2025, with a predicted 60-day performance period following contract award.
This procurement is designated as a 100% small business set-aside under NAICS code 334290 (Other Communications Equipment Manufacturing) with a size standard of 800 employees. No incumbent contractor information is provided in the available documentation, and no specific contract value or budget range is disclosed. The contractor must deliver and install 7 complete CO Detection Monitor Systems to Building 223 at Columbus Air Force Base, with the primary performance location being 158 Simler Blvd Building 214, Columbus, Mississippi. The system is needed immediately to protect personnel from carbon monoxide exposure during firearms training activities. The contractor will be required to provide all materials including conduit and must ensure the system operates as a standalone unit without integration into existing HVAC or fire alarm systems.
Notice text
Columbus Air Force Base requires a 7-point Carbon Monoxide (CO) detection system with central monitoring capabilities. The central monitoring system must provide a comprehensive overview of CO levels across the entire range and trigger audible and visual alarms in the event of dangerous CO concentrations. The system must meet or exceed the following specifications:
System Components:
· 87 Digital / 12 Analog Inputs with 3 Relays, 10A SPDT, Dual 24VDC Outputs, and LCD Display
· Power Supply: 115VAC-60HZ, 6AMP with 4 Outlets at 24VDC
· Alert Beacon: Audible Horn and Blue Light Strobe Combo
· Fixed Gas Detector: Wall-mounted, 4-20mA with 2 Relays and 5A SPDT 12-24VAC/12-32VDC, 0-200PPM
· Module Bus Adapter: Signal Converter (4-20mA Analog to Digital)
· Calibration Kit: Tygon 2ft Cal Hood with 0.2LPM Regulator for CO Calibration Tests
· CO Cylinder: 17L 200PPM Bump Calibration Cylinder
Quantity:
· 7 complete CO Detection Monitor Systems
The contractor shall:
· Supply the specified CO Detection Monitor System.
· Deliver the system to Columbus Air Force Base, MS, Building 223, CATM Section Chief.
· Install and test the system to ensure proper functionality.
· Provide training to designated 14 SFS personnel on the system's operation and maintenance.
Please see Statement of Need for more information.
Attachments
| File | Type | Posted |
|---|---|---|
| FA302225Q0332 Carbon Monoxide Detector - Vendor Questions Updated.pdf | ||
| FA302225Q0332 Carbon Monoxide Detector - Provisions and Clauses Updated.pdf | ||
| Attch 1-FA302225Q0332 Carbon Monoxide Detector - SON - Carbon Monoxide Detection - 15 Aug.docx | DOCX document | |
| Attch 1 - FA302225Q0332 Carbon Monoxide Detector- SON - Carbon Monoxide Detection - 15 Aug.docx | DOCX document | |
| Attch 2 - FA302225Q0332 - Provisions and Clauses.pdf | ||
| FA302225Q0332 Carbon Monoxide Detector - Combined Synopsis Solicitation.pdf | ||
| Solicitation.pdf | ||
| Provisions and Clauses.pdf | ||
| Statement of Need.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| Carbon Monoxide Detectors | Solicitation | |
| Carbon Monoxide Detection System, Columbus AFB | Solicitation |
On GovTribe
Work this opportunity on GovTribe
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity