Carbon Monoxide Detectors

Closed Solicitation Posted

Solicitation number
FA302225Q0332
Agency
Air Education and Training Command Air Force, Department of Defense
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
334290 Other Communications Equipment Manufacturing
PSC
6350 Miscellaneous Alarm, Signal, And Security Detection Systems
Place of performance
Columbus, Mississippi 39710, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Air Education and Training Command is procuring a comprehensive 7-point Carbon Monoxide detection system with central monitoring capabilities for a firing range at Columbus Air Force Base. The system must include 87 digital/12 analog inputs with 3 relays, power supply, alert beacon, wall-mounted fixed gas detectors capable of monitoring 0-200 PPM, module bus adapter, calibration kit, and CO cylinder for bump testing. Beyond supplying the equipment, the contractor must deliver, install, and test the complete system to ensure proper functionality, as well as provide operational and maintenance training to 14 SFS personnel. The solicitation follows Federal Acquisition Circular 2025-05 standards for commercial services. Questions are due by September 15, 2025, with final offers due September 18, 2025 at 4:30 PM CST, providing a tight 10-day response window from the posting date of September 8, 2025.

This procurement is designated as a 100% small business set-aside under NAICS code 334290 (Other Communications Equipment Manufacturing) with a size standard of 800 employees. The solicitation requires delivery of 7 complete CO Detection Monitor Systems to Building 223, CATM Section Chief at Columbus Air Force Base, Mississippi. Performance will occur at the 14 SFS S3D facility in Columbus, MS 39710, where the contractor will be responsible for installation, testing, and training activities. The point of contact is Joseph Besko, who can be reached at joseph.besko@us.af.mil or 662.434.3290 for inquiries. No incumbent contractors or specific award values are mentioned in the available documentation, though the technical specifications suggest a specialized safety monitoring system for military firearms training operations.

Notice text

7-point Carbon Monoxide (CO) detection system with central monitoring capabilities for firing range. The central monitoring system must provide a comprehensive overview of CO levels across the entire range and trigger audible and visual alarms in the event of dangerous CO concentrations. The system must meet or exceed the following specifications:
 
· System Components:
· 87 Digital / 12 Analog Inputs with 3 Relays, 10A SPDT, Dual 24VDC Outputs, and LCD Display
· Power Supply: 115VAC-60HZ, 6AMP with 4 Outlets at 24VDC
· Alert Beacon: Audible Horn and Blue Light Strobe Combo
· Fixed Gas Detector: Wall-mounted, 4-20mA with 2 Relays and 5A SPDT 12-24VAC/12-32VDC, 0-200PPM
· Module Bus Adapter: Signal Converter (4-20mA Analog to Digital)
· Calibration Kit: Tygon 2ft Cal Hood with 0.2LPM Regulator for CO Calibration Tests
· CO Cylinder: 17L 200PPM Bump Calibration Cylinder
 
· Quantity: 7 complete CO Detection Monitor Systems
 
The contractor shall:
· Supply the specified CO Detection Monitor System.
· Deliver the system to Columbus Air Force Base, MS, Building 223, CATM Section Chief.
· Install and test the system to ensure proper functionality.
· Provide training to designated 14 SFS personnel on the system's operation and maintenance.

Attachments

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Carbon Monoxide Detectors This notice · Latest solicitation Solicitation
Carbon Monoxide Detection System, Columbus AFB Original Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity