C1DA--AE-NRM-687-26-100 Modernize Physical/Electronic Security Systems
Closed Pre-Solicitation Posted
- Solicitation number
- 36C26026Q0149
- Agency
-
Veterans Integrated Service Network 20
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 541512 Computer Systems Design Services
- Place of performance
- Department of Veterans Affairs Jonathan M. Wainwright Memorial VA Medical Center Walla Walla WA 99362, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration, Veterans Integrated Service Network 20, is conducting market research for an Architect-Engineer (A-E) contract to modernize physical and electronic security systems at the Jonathan M. Wainwright Memorial VA Medical Center in Walla Walla, Washington, along with several community-based outpatient clinics in Washington and Oregon. The procurement seeks comprehensive design services including site visits, field investigations, studies, user interviews, and the preparation of drawings, specifications, and cost estimates for replacing end-of-life physical access control systems (PACS), security surveillance systems (SSTV), and intrusion detection systems. Required qualifications include design professionals with certifications such as Certified Protection Professional (CPP), Physical Security Professional (PSP), GISCP, CISSP, and RCDD, with the project targeted toward small businesses under NAICS code 541512. This is a Sources Sought announcement for market research purposes only and is not a formal solicitation or request for proposals; responses will be used to inform the government's acquisition strategy and are not binding. Interested firms must submit a two-page capabilities statement addressing design requirements, past performance, project timeline, and business classification by November 25, 2025, at 3:00 PM Pacific Time to Sangmi.Kim@va.gov.
This opportunity is designated with no set-aside, and no current incumbent or prior contractor information is identified in the pre-solicitation materials. The estimated construction magnitude for this project ranges between $5,000,000 and $10,000,000, reflecting the comprehensive scope of security system modernization across multiple facilities. The design phase is structured over 365 calendar days with specific submittal deadlines for quality assurance, basis of design, schematic design, design development, and construction documents, with the project managed by Network Contracting Office 20 and overseen by a designated Contracting Officer's Representative. The A-E must implement a FIPS 201 compliant network platform, replace lock cores and door hardware, extend data infrastructure, and incorporate electronic security systems while providing 20 percent capacity for future expansion. Supporting documentation includes comprehensive facility condition assessments, campus maps, fiber optic distribution site plans, telecommunications infrastructure details, and the VA's Physical Security and Resiliency Design Manual to guide the design work.
Notice text
Sources Sought - Solicitation Number: 36C26026Q0149
Project 687-26-100 Modernize Physical and Electronic Security Systems
This is a Sources Sought announcement only. This is not a request for proposals, quotations, or bids; nor a synopsis of a proposed contract action under FAR Subpart 5.2 and no contract shall be awarded from this notice. No reimbursement will be made for any costs associated with providing information in response to this Sources Sought or any follow-up information requests. No solicitation is currently available. Draft documents are subject to change.
Attachments;
Source Sought Questionnaire 687-26-100
Physical Security and Resiliency Design Manual
AE SOW 687-26-100
SOW Attachment 01 - Required Div 01 Spec Sections
SOW Attachment 02 - Sensitive Infrastructure Data Classification Memo
SOW Attachment 03 - 01 32 16.01 EHRM A-E CPM Schedules
SOW Attachment 04 - VAWW Campus Map
SOW Attachment 05 - Fiber Optic Distribution Site Plan
SOW Attachment 06 - Engineering Design Waiver Template
SOW Attachment 07 - STN 687 PG-18-15, Volume C, A-E Submission Instructions
SOW Attachment 08 FCA Report Redacted
This notice is for market research purposes to gain knowledge of interest, capabilities, and qualifications of interested Small Business firms. Responses to this Sources Sought may shape the acquisition strategy in developing a competitive requirement. Not responding to this notice does not preclude participation in any future or potential solicitation. It is the intent of the VA to use the information gathered for market research purposes only.
The Veterans Health Administration, Regional Procurement Office West, Network Contracting Office 20, is conducting market research for an Architect-Engineer (A-E) contract to modernize the physical and electronic security systems.
PROJECT OVERVIEW
High Level Scope of Work
Site visits, field investigations, reports from investigations, studies, and user interviews to prepare drawings, specifications, and cost estimates for all facets of work and disciplines/trades to facilitate a construction project to replace the campus physical access control (PACS) and security surveillance systems (SSTV), inclusive of all equipment, programming, accessories, and infrastructure required for a fully functioning, modernized, fully integrated single network and software platform on the Walla Walla VAMC campus.
Project will expand coverage of PACS and SSTV to close security vulnerabilities. All lock cores and, as necessary for compatibility with new cores and PACS equipment, door hardware shall be replaced throughout the domain of the Walla Walla VAMC. Additionally, lock cores, and door hardware where necessary to accommodate new lock cores, shall be replaced at Community Based Outpatient Clinics (CBOCs) and Primary Care Telehealth Outpatient Clinics (PTOC) located in Union Gap, WA; La Grande, OR; and Boardman, OR. Aged, failing, and incompatible surveillance cameras will be replaced.
Design Discipline Requirements
Architectural To assess if the door frame and door hardware is able to support the installation of electronic security devices for PACS hardware.
Electrical To assess if there is enough available power within each of the buildings to support the systems.
Physical Security For electronic systems and site risk assessment the following certifications are required: CPP or PSP from ASIS (American Society Industrial Security) is required.
Certified Protection Professional (CPP) For facility risk determination to inform what areas of the medical center will require certain levels of security equipment.
Physical Security Professional (PSP) or Certified System Integrator (CSI), Certified Fire Alarm Designer (CFAD), and Certified Service Technician (CST) Required for systems integration and management of IT security strategies.
Global Industrial Cyber Security Professional (GISCP) or Certified Information Systems Security Professional (CISSP) Needed for network and security design for the security hardware.
Registered Communications Distribution Designer (RCDD) Required for telecommunications design.
** See the attached Physical Security and Resiliency Design Manual (Rev 06-01-2025):
Section 2.1.2 Requirements for a Certified Physical Security Specialist (Page 2-2)
Annex to Chapter 10 - A-10.1 through A-10.1.5 (Page 10-36)
PROJECT LOCATION
Work is located at Jonathan M. Wainwright Memorial VA Medical Center- Walla Walla, WA 99362. For the principal components of work, see the attached draft statement of work and supporting documents. Documents are currently in draft state and industry comment / suggestions are greatly encouraged and welcomed.
The estimated magnitude for this project is between $5,000,000 and $10,000,000
NAICS AND SIZE STANDARD
Sources are being sought for firms with a North American Industry Classification System (NAICS) code of 541512 Computer Systems Design Services, a Product Service Code (PSC) of C1DA and a Small Business Size Standard of $34.0 million. Sources are highly encouraged to respond to this notice.
RESPONSE REQUIREMENTS
Responses are requested with the following information and shall not exceed a total of 2 (two) pages. Email subject line needs to contain the solicitation number 36C26026Q0149.
Please provide the following information:
Contact information: Name, address, SAM.gov UEI number, and points of contact with telephone numbers and e-mail addresses.
Business Size/Classification (based on NAICS 541512):
Is your firm eligible for participation in one of the following small business programs? If so, please indicate the program.
[ ] yes [ ] no Small Business (SB)
[ ] yes [ ] no HUBZone
[ ] yes [ ] no Small Business 8(a)
[ ] yes [ ] no Small Disadvantaged Business (SDB)
[ ] yes [ ] no Women-Owned (WO) Small Business
[ ] yes [ ] no Service-Disabled Veteran Owned Small Business (SDVOSB)
[ ] yes [ ] no Veteran Owned Small Business (VOSB)
[ ] yes [ ] no Other (please specify)
Capabilities Statement: Description of capabilities to perform A/E design services as described above and project experience demonstrating relevant experience similar to those described. Please specifically address how your firm meets the requirements outlined in the Project Overview section, including the required design discipline capabilities and certifications.
Govt. does not have a waiver to Buy American.
SDVOSB or VOSB businesses please include statement on maintaining compliance with VAAR 852.219-75 VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction.
All other socio-economic businesses please include statement on maintaining compliance with FAR 52.219-14 Limitations on Subcontracting.
Time: Based on the information provided, please estimate the total project time in days.
Past Performance/experience: Provide information on contracts of similar scopes of work or construction contracts, briefly describe no more than three (3) contracts (or specific task orders) completed within the past five years of the issue date of this Sources Sought notice. The past performance information should include:
Project Title/Contract Number
Location: City, State
General description of the A-E to demonstrate relevance to the proposed project
Offerors role
Dollar value of contract
Name of the company, agency, or government entity for which the work was performed
What types of information is required to submit accurate offers?
If submitting past performance/experience on a project in the role of a subcontractor, include the Prime Contractor s name and a quantifiable amount (percentage) of the project your company contributed to the overall scope of work.
Note: Do not include Proprietary, classified, confidential, or sensitive information in responses.
NO RESPONSES WILL BE ACCEPTED BY FAX.
Responses will not be returned. Telephonic responses will not be honored. Please respond by email only. Send responses to the Contract Specialist, Sangmi Kim at Sangmi.Kim@va.gov.
Responses will be accepted until November 25, 2025, 3:00 PM Pacific Time.
Files
Show all 12
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| J063 Service and Software Updates to Security Access Control and Camera Systems Across Idaho/ Eastern Oregon VA Locations | Veterans Integrated Service Network 20 | No set-aside | |
| Y1DZ--PCAC EHRM Infrastructure Upgrades Construction - Togus VAMC (VA-27-00009716) | VA Technology Acquisition Center | No set-aside | |
| C1DA--NRM A/E- 528A7-27-112 Fire Alarm Panel Upgrade | Veterans Integrated Service Network 2 | No set-aside | |
| C1DA--PROJECT 528A5-27-503 A/E Design Replace Flat Roofs Canandaigua VAMC | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business | |
| Project 652-322 | A/E Design Refresh & CPS Services for CLC | Richmond, VA | VA Technology Acquisition Center | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity