Bldg 2000 Secure Area Upgrades

Closed Pre-Solicitation Posted

A newer solicitation was posted. See the latest solicitation from .

Solicitation number
W50S8P25BA001
Agency
Army National Guard Department of the Army, Department of Defense
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
236220 Commercial and Institutional Building Construction
PSC
Z2AA Repair Or Alteration Of Office Buildings
Place of performance
Columbus, Ohio 43217, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Army National Guard, specifically the 121st Air Refueling Wing at Rickenbacker Air National Guard Base, is seeking a contractor to perform comprehensive security upgrades to a 750 square foot office suite. The project involves modifying the space to meet ICD 705 security standards, which includes upgrading perimeter walls to achieve an STC 50 rating with sound attenuation and RF shielding, removing and infilling existing windows, managing utility and HVAC duct penetrations, and installing a new STC 50 security door with specific hardware requirements. Interested prime contractors must submit a five-page response by June 6, 2025, to 121.msg.contracting@us.af.mil, including a statement of intent, a completed sources sought form, project history, and details about resources and key personnel. The evaluation will likely focus on the contractor's ability to meet stringent security specifications, past performance, and technical capabilities. Responses must include a comprehensive list of completed projects from the past three years, demonstrating relevant experience in secure facility modifications.

The contract is set aside for small businesses, with a potential award value between $250,000 and $500,000. If adequate small business contractors are not available, the opportunity may be advertised as unrestricted. Interested firms must be registered in the System for Award Management (SAM) and provide information about their socio-economic classification, such as woman-owned or service-disabled veteran-owned business status. The project requires contractors to have bonding capability for construction projects and the ability to conduct thorough RF shielding attenuation testing. The scope of work includes ensuring all new finishes match the existing aesthetic while creating a cohesive and secure environment. Contractors will need to demonstrate technical expertise in sound masking, security door installation, and RF shielding techniques specific to high-security government facilities.

Notice text

Building 2000 Secure Area Update Sources Sought

The purpose of this synopsis is to gain knowledge of potential sources for this project including interested Small Business sources. This notice is for planning purposes only. All interested parties should respond. Rickenbacker Air National Guard Base, Ohio intends to issue a solicitation and award of a contract to “Building 2000 Secure Area Update”.
The magnitude of this project is between $250,000 and $500,000. All interested concerns will provide this office, in writing, a notice stating their positive intent to submit a proposal as a prime contractor no later than 6 June 2025. This notification, which shall not exceed five typewritten pages, must include (1) positive statement of intent to bid as a prime contractor, and (2) a completed and signed Source Sought Information Request Form (add link to form) and (3) A listing of projects completed during the past three years, both for government and private industry. The type of project, dollar value, Contract number, location, and Point of Contact are to be included. Indicate if you were prime or subcontractor, and if subcontractor, provide the name and point of contact for the prime contractor. (4) A brief outline of resources, subcontractors, and key personnel that would be used to accomplish the contract.
In the event adequate Small Business contractors are not available for adequate competition for this project, it may be advertised as unrestricted. Information shall be provided via email to: 121.msg.contracting@us.af.mil. Include the following in the subject line "Sources Sought W50S8P-25-B-A001". No facsimile responses will be honored.

Project Summary 

To enhance security at the 121st Air Refueling Wing facility, the contractor will undertake a comprehensive modification of a 750 sf. office suite to meet stringent ICD 705 standards. This involves upgrading perimeter walls to achieve an STC 50 rating with sound attenuation and RF shielding, removing and infilling existing windows, managing utility and HVAC duct penetrations with sound masking and security measures, installing a new STC 50 security door with specific hardware requirements, and conducting thorough RF shielding attenuation testing to ensure compliance. The work also includes matching all new finishes to the existing aesthetic, ensuring a cohesive and secure environment.

Attachments

Files attached to this notice, newest first
File Type Posted
Sources Sought Response Form.pdf PDF

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Bldg 2000 Secure Area Upgrades Latest solicitation Solicitation
Bldg 2000 Secure Area Upgrades Pre-Solicitation