B2145 Chiller Leak & B23265 Power Relay Board

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
FA468624Q0008
Agency
Air Combat Command Air Force, Department of Defense
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
J041 Maint/Repair/Rebuild Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
Place of performance
Beale AFB, California 95903, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice seeks offers for two chiller repair projects for the Department of the Air Force Air Combat Command. Specifically, it requires inspecting and performing necessary repairs on a leaking chiller at Building 2145, including recovering the refrigerant charge, performing leak checks, and replacing a temperature sensor. It also requires procuring, delivering, and installing a compatible power relay board for a chiller at Building 23265. Offerors must provide pricing and availability to complete both repair projects by March 5, 2024 as indicated in the attached Statement of Work.

The opportunity is set aside for total small businesses. The primary NAICS code appears to be 238220 - Plumbing, Heating, and Air-Conditioning Contractors, with the predominant PSC code R499 - Operation and Maintenance of Equipment. No incumbent or current contractors are identified. The solicitation number is FA468624Q0008 and the budget is unspecified, but the requirement is to repair two chillers so the award value is likely under $500,000 given the nature and scope of the work.

Notice text

DUTY 1:  Trane chiller (serial # L16H04129) located at Building 2145: Inspect for damage and operational capabilities, recover refrigerant charge from the unit, perform leak checks, replace evaporator temperature sensor, and determine necessary repairs.

DUTY 2:  Power Relay Board located at Building 23265:  Procure, deliver, and install compatible power relay board required for Trane Chiller with serial number #L15H04455.

See attached SOW for additional information.

Attachments

Files attached to this notice, newest first
File Type Posted
SOW - Chiller Repairs 2145 and 23265.docx DOCX document

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
HVAC Water Testing and Treatment Services Award Award Notice
HVAC Water Testing and Treatment Services Latest solicitation Solicitation
B2145 Chiller Leak & B23265 Power Relay Board This notice · Original Pre-Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity