B103 Repair Mechanical Systems and Building Improvements

Closed Solicitation Posted

Solicitation number
N40080-24-R-3956
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Patuxent River, Maryland 20670, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Navy Naval Facilities Engineering Command is seeking contractors to repair mechanical systems and make building improvements at the Naval Air Station Patuxent River in Maryland. The project includes replacing deteriorating HVAC equipment such as 27 hydronic floor-mounted fan coil units, 2 rooftop package units, 2 mini-split air conditioning units, 4 ceiling exhaust fans, and 1 baseboard heater. The work also involves modifying existing piping and ductwork, installing a new dedicated outdoor air system (DOAS) unit, and replacing acoustical ceiling tiles. The solicitation requires providing all labor, materials, equipment, and supervision to complete the work within 305 calendar days. Proposals are due by June 3, 2024 and will be evaluated based on the lowest priced, responsible offer.

This contract opportunity is not set-aside. The government has not identified any potential incumbents. The estimated budget for the project is $1,371,000, and the work must be performed at the Naval Air Station Patuxent River complex in Patuxent River, Maryland. A site visit is scheduled for May 9, 2024 and pre-proposal inquiries are due by May 16, 2024.

Notice text

The project includes but is not limited to replacement of deteriorating (27) hydronic floor mounted fan coil units to include associated fittings, piping, valves, and accessories. (2) 7.5 ton rooftop package units to include associated, disconnect switches, circuit breakers, conduits, wirings, piping, valves, temperature sensors, controls, and accessories. (2) Mini-split type a/c unit to include associated disconnect switches, circuit breakers, conduits, wirings, piping and accessories located in IDF room and locker room. (4) Ceiling exhaust fans and associated accessories located in first floor toilet male and female rooms, locker room, and weather office room– 104. (1) Baseboard heater unit and associated accessories located in second floor corridor 100 entryway.

The new work includes of the following:

1) Provide and install (27) new ceiling cassette type fan coil units to include associated fittings,

valves, piping, insulation, hanger support, digital control, and accessories. Provide fan coil units

that match the existing chiller unit brand.

2) Modify existing fan coil units piping (cold/hot) as required for proper installation of new ceiling cassette type units. Remove any unused piping, fittings, valves, and associated accessories. Where required, drywall is removed add layer of ½ rigid expanded polystyrene (EPS) foam.

3) Provide and install (2) new 7.5 ton rooftop package units to include associated, disconnect

switches, circuit breakers, conduits, wirings, piping, valves, temperature sensors, digital controls,

and accessories. Provide necessary equipment required for ductwork cleaning. At no time both

units will be down. Provide and install (2) pole metal mounted for disconnect switches.

4) Provide and install new (2) mini-split type a/c unit with cooling only to include associated

disconnect switches, circuit breakers, conduits, wirings, piping and accessories located in IDF

room and locker room. Existing housekeeping pads may reused if good condition is acceptable.

5) Provide and install new (4) ceiling exhaust fans located in first floor toilet male and female rooms, locker room, and weather office room– 104.

6) Provide and install new baseboard heater unit and associated accessories located in second floor corridor 100 entryway.

7) Provide and install new ceiling exhaust fan in second floor room 205; shower and toilet rooms to include circuit breakers, conduits, wirings, and associated accessories.

8) Provide and install new dedicated outdoor air system (DOAS) unit to include associated

ductwork, housekeeping pad, disconnect switch, circuit breakers, conduits, wirings, control,

sensors, and accessories. Provide design for DOAS unit to include ductwork and electrical

systems. Perform load calculation to determine appropriate size unit.

9) Provide and install new acoustical ceiling tiles and associated accessories that match the existing patterns and finishes.

10) Modify existing electrical panel to adapt serve new DOAS unit and ceiling exhaust fans.

Existing electrical wiring may reused if capacity is adequate and in good condition.

Building will remain occupied during construction. Very important, heating, cooling, and dehumidification shall be maintained in the Air Traffic control operation room during this project.

Files

Similar open opportunities

Opportunity Agency Set-aside Responses due
Replace HVAC Rooftop Units at Building 2275 March Air Reserve Base, California 92518, United States · NAICS 238220 Army National Guard No set-aside
Repair Mechanical Systems IDIQ (FY 27-32) Wright Patterson Afb, OH 45433 United States 45433 · NAICS 238220 AFLCMC Wright Patterson AFB No set-aside
Maintenance and Service for Deionized (DI) Water Systems Patuxent River, Maryland 20670, United States · NAICS 811210 Naval Air Warfare Center Total Small Business
BPA - Air Conditioning and Warm Air Heating PSC 4120, 4130 Indian Head, Maryland 20640, United States · NAICS 333415 Naval Sea Systems Command Total Small Business
HVAC Unit Replacement NAICS 238220 National Oceanic and Atmospheric Administration Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity