About this opportunity
The Department of Energy Office of Science, operating through Argonne National Laboratory, is seeking to procure specialized scientific equipment consisting of two ACSM Detectors and two TOF-ACSM SMA-SMA Cables for mass spectrometry systems. The solicitation requires vendors to submit a comprehensive quotation package including a signed RFQ form, completed representations and certifications, a published price list demonstrating pricing reasonableness, country of origin verification, and lead time confirmation. Technical specifications for the ACSM Detector are stringent, demanding an electron multiplier detector with high gain capability (106 to 107), operational voltage range of 1,500-3,000 V, and compatibility with ultra-high vacuum conditions. Evaluation criteria will focus on technical compliance, with bids not meeting precise specifications being automatically disqualified. The quotation deadline is March 31, 2025, with the solicitation posted on March 25, 2025.
The contract opportunity is not set aside for any specific business category and is open to all qualified vendors. The place of performance is located in Lemont, IL 60439, with the procurement falling under NAICS category 423490 for Other Professional Equipment and Supplies Merchant Wholesalers. While specific award value is not disclosed, the solicitation seeks two units each of the ACSM Detector and SMA-SMA Cable, with detailed technical requirements including vacuum compatibility, specific connector types, and precise operational parameters. Potential vendors are encouraged to verify if they have existing DOE or GSA contract pricing that might be applicable. The procurement is for scientific equipment designed for high-resolution ion pulse detection and mass spectrometry systems, with strict requirements for materials, operational conditions, and technical performance.
Notice text
Provide the following with your quotation:
1. Signed Page one of the RFQ (ANL-70).
2. Completed Representations and Certifications (ANL-70A).
3. Provide a published price list or a redacted invoice showing pricing for the quoted, to prove price reasonableness.
4. Verify the country of origin.
5. Confirm lead time.
6. Are there any discounts available for DOE or does this order fall under GSA contract pricing (if yes, please include contract #and expiration date).
Technical Specifications:
Please review this carefully. Any bids received that do not meet the technical specifications will not be considered
1. ACSM Detector E:
a. Detector type: Electron multiplier or discrete dynode detector
b. Flanged mounting for integration into vacuum housing (compatible with flange-mounted ToF systems)
c. High gain capability: Typical gain in the range of 10⁶ to 10⁷
d. Operational voltage range: 1,500–3,000 V
e. Response time: ≤1 μs (suitable for high-resolution ion pulse detection)
f. Vacuum compatibility: Operable under ultra-high vacuum conditions (10⁻⁶ Torr or lower)
g. Materials: Ultra-high vacuum-compatible materials (e.g., stainless steel housing, ceramic insulators)
h. Interface: Compatible with dual-filament ion source configurations in ToF-ACSM systems
2. Physical dimensions: Must conform to typical footprint for ACSM flange-mounted detectorsTOF-ACSM SMA-SMA Cable Preamp-to-ADQ
a. Cable type: Coaxial RF signal cable
b. Connectors: SMA Male to SMA Male
c. Impedance: 50 ohms
d. Shielding: Double-shielded construction to minimize electromagnetic interference
e. Frequency bandwidth: Minimum 3 GHz (to support high-speed analog signal transmission)
f. Length: 1 meter (±10 cm tolerance acceptable)
g. Application: Designed for low-noise transmission between preamplifier and high-speed digitizer in mass spectrometry systems
h. Operating temperature range: –20°C to +60°C
Files
| File | Type | Posted |
|---|---|---|
| ANL-70 RFQ.doc | DOC document | |
| ANL-70A Reps and Certs Short.pdf | ||
| Appendix A-71COM-13-FEB-2023.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Spectrum Analyzer, No Equivalents Or Substitutions | Office of Science | No set-aside | |
| PIP-II ssrs and LB650 vacuum gauge and readout | Fermi National Accelerator Laboratory | No set-aside | |
| GEMINI. HP. L. ASY: interferometer, Gemini-Felix, and PDM module | Department of Energy | No set-aside | |
| NOVO DR Inc. , Discovery III System 22WNH - Bright XL, and accessories | Department of Energy | No set-aside | |
| LT-SPM | Office of Science | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity