7320--Industrial Kitchen Cart Washer

Closed Solicitation Posted

Solicitation number
36C24525Q0824
Agency
Veterans Integrated Service Network 5 Veterans Health Administration, Department of Veterans Affairs
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

NAICS code
333310 Commercial and Service Industry Machinery Manufacturing
PSC
7320 Kitchen Equipment And Appliances
Place of performance
C/O Department of Veterans Affairs at Clarksburg Wv Va Medical Center Valencia, PA. 16059, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs VA Maryland Health Care System is procuring an ALVEY KS-88 Industrial Cart Washer or equivalent for the Louis A. Johnson VAMC as part of a facility renovation project. This commercial industrial kitchen equipment must feature a 102" long x 36" wide x 80" high wash chamber constructed of type 304 stainless steel, a 15 HP TEFC motor delivering 400 GPM at 35 PSI, and a 225-gallon tank capacity with pass-through front and rear entry design. The cart washer must include NSF certification, digital temperature controls, a NEMA 4X stainless steel control panel, steam-heated coils, and pit-mounted design with safety features. The evaluation criteria will assess salient characteristics, price, product literature, authorization letter, delivery lead times, and country of origin. Proposals are due September 12, 2025, at 5:00 PM Eastern Time, with delivery required within 60 days after order receipt.

This procurement is set aside exclusively for Service-Disabled Veteran-Owned Small Businesses under NAICS code 333310 (Commercial and Service Industry Machinery Manufacturing) with a size standard of 1000 employees. No current contractors or incumbents are identified in the solicitation documents. While no specific contract value or budget range is disclosed, this appears to be a single-unit procurement given the detailed specifications for one industrial cart washer. The equipment must be delivered to BOVA Corporation located in Valencia, Pennsylvania 16059, with the point of contact being Beth Bova for delivery coordination. The contractor will be required to provide three copies of Safety Data Sheets and must comply with specific records management requirements and subcontracting limitations as outlined in the firm-fixed-price contract structure.

Notice text

ALVEY KS-88 INDUSTRIAL CART WASHER

Brand name or Equal

Scope of Work

The contractor shall deliver the unit to the location stated below. Louis A. Johnson VAMC is drawing up a contract for renovation and the facility is seeking new equipment.

Specifications

Salient Characteristics:

Features Include:

Wash Chamber section

Wash chamber 102 long, 36 wide, and 80 height

Constructed of type 304 stainless steel with polished finish

Panel-Z type interlocking double flange type seal

Two counter-rotating stainless steel spinning arm assemblies

Stainless steel wash nozzles

Stationary fresh water rinse on top and sides with brass nozzles

23.5 gallons of fresh rinse water to replenish wash tank each cycle

Wash Pump

15 HP TEFC (totally enclosed fan cooled) motor, vertically mounted pump delivering 400 GPM at 35 PSI

Stainless steel wash and rinse pipes

Pump protection screen

Tank and Housing

Tank constructed of 12 gauge type 304 stainless steel

Housing constructed of 16 gauge type 304 stainless steel

Removable stainless steel filter screens

225 gallon tank capacity (290 if gas heat)

Door(s) Pass-Thru front and rear entry walk-through design

38 wide x 83 high opening

Interior safety release latch

Triple hung (3 hinges) for added durability

Control Panel

UL listed NEMA 4X stainless steel panel

Three pre-set cycle times

Automatic water fill

Electronic temperature control

Digital wash and rinse temperature indicators

Wash and rinse pressure gauges

Additional Features

NSF certified

Pit mounted design

Safety guard rail

Anti-slip floor

Washer shipped knocked down for field assembly

High capacity exhaust fan

Wash down hose and nozzle

Heating

Stainless steel steam heated coils

Warm rinse steam heat booster

NOTE: Insulation (piping or otherwise) is not included and is to be provided and applied by customer.

Pressure regulation of the gas, steam, and / or water utilities is required for proper operation of this equipment. Gas regulators and pressure reducing valves are not included and are the customer s responsibility to provide to ensure the specified operating pressures & ranges are maintained.

Voltage

220/240V/3PH/60HZ

Delivery Location

Attn: (Beth Bova)

BOVA Corporation

111 McFann Rd

Valencia, PA 16059

Email: beth@bovacorp.com

Prior to delivery, Contracting Officer Representative and/or Service Line Representative shall receive shipping information from Contractor and forward to Beth Bova and Logistics using the email(s) listed above.

The Contractor must comply and provide all necessary information to VA Clarksburg. Otherwise, the delivery may be refused and require redelivery at no additional cost to the government.

Requested Delivery Date

Delivery of equipment is requested to occur with 60-days after receipt of order. While installation is not required, once our service installs the equipment, training will be required once it is scheduled by the service.

Attachments

Files attached to this notice, newest first
File Type Posted
36C24525Q0824 Cart Washer.pdf PDF
36C24525Q0824_1.docx DOCX document

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity