Vivarium Tunnel Washer

Open Pre-Solicitation Posted

Solicitation number
36C24727Q0119
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Decatur, Georgia 30033, United States

Notice details come from SAM.gov. Updated .

About this opportunity

Department of Veterans Affairs, Veterans Health Administration, Veterans Integrated Service Network 7 is requesting product documentation for a non-standard 30-inch conveyor belt tunnel washer replacement, with submissions due November 30, 2026. No set-aside is used. Replacement equipment must fit the existing restricted wall opening of 49 inches wide by 78 inches tall, which the notice states excludes a standard 36-inch conveyor unit. Smaller-than-30-inch conveyor belts or shorter wash chambers are unacceptable for operational and safety reasons. The wall-to-machine interface must prevent gaps, which the notice identifies as a biohazard risk allowing cross-contamination between dirty and clean areas. Submissions include a product description for consideration.

The attached SOW, as summarized by the government file, places the work at the Atlanta VA Medical Center Veterinary Medical Unit and covers removal of the existing washer and debris, shipping and installation, final utility connections within five linear feet of connection points, assembly, leveling, startup, and one operator and supervisor training session. The same summary states the funding source is a Lab Animal Major Equipment grant from the Office of the Chief Veterinary Medical Officer. Vendor network access, software installation, and VA system connections are not permitted.

Notice text

Please view the SOW attached.

Submit documentation with description for considerations of products.

Tunnel washer:

  • Facility infrastructure constraints limit replacement equipment to the footprint of the existing tunnel washer.
  • Restricted wall opening dimensions of 49" wide x 78" tall dictate the maximum equipment size.
  • Requires a non-standard 30" conveyor belt tunnel washer because a standard 36" conveyor belt unit cannot fit through the existing opening.
  • Smaller-than-30" conveyor belts or shorter wash chambers are unacceptable due to operational and safety concerns.
  • Maintaining a proper wall-to-machine interface is critical to prevent gaps between the washer and wall opening.
  • Gaps would create biohazard risks, allowing potential cross-contamination between dirty and clean areas.

Files

File Type Posted
SOW - Getinge tunnel washer.docx DOCX document

On GovTribe