6640--NEW - Biomerieux Biofire Consumables
Cancelled Pre-Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 36C25724Q0258
- Agency
-
Veterans Integrated Service Network 17
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 325413 In-Vitro Diagnostic Substance Manufacturing
- PSC
- 6640 Laboratory Equipment And Supplies
- Place of performance
- South Texas Veteran Healthcare System Audie L. Murphy VA Hospital San Antonio, Texas 78229, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This pre-solicitation notice seeks sources for brand name reagent kits compatible with Biofire Film Array instrumentation in the microbiology laboratory of the South Texas Veteran Healthcare System, part of the Department of Veterans Affairs Veterans Health Administration VISN 17. The five-year contract requires acknowledgement of orders within 24 hours, emergency delivery of supplies within 24 hours if defective or late, and compliance with all applicable laws and accreditation standards. Responses to the sources sought notice are due by January 31, 2024.
There is no set-aside designation. The contract would provide 30 tests each of Biofire RP2.1, BCID2, GI, ME, Pneumo, and joint infection panels, totaling over 300 panels. Emergency delivery is required until the monthly standing order arrives if additional requests are necessary.
Notice text
STATEMENT OF WORK (SOW)
Scope
The STVHCS has a need for brand name reagent kits compatible with the government owned Bio Fire Film Array Instrumentation in the Microbiology Laboratory of Pathology & Laboratory Medicine Service at Audie L. Murphy VA Hospital. The FDA Approved Film Array Panel tests for a comprehensive set of pathogens. These panels aid in quickly identifying the correct pathogen and ensure appropriate treatment, patient management and help decrease infectious diseases which can lead to severe illness or death.
Vendor must meet the following requirements:
The kits must be compatible with the Bio Fire Film Array Instrumentation Model#FLM2-ASY-0001
Vendor must acknowledge receipt of order within 24 hours and provided estimated shipping timeframe.
The kits must be FDA approved.
The Contractor must be able to provide an as needed continuous stock of inventory of the below listed reagents.
The Contractor must be able to provide an emergency plan in case reagents are found to be defective and unsuitable for use at no additional cost.
The kits must be maintained and delivered following all Federal and State regulations as applicable.
Item #
Description/Part Number*
Qty
423742
Biofire RP2.1 Panel, 30 Tests IVD 423742
87
RFIT-ASY-0147
Biofire BCID2 Panel, 30 Tests-RFIT-ASY-0147
30
RFIT-ASY-0116
Filmarray GI Panel, 30 Tests-RFIT-ASY-0116
75
RFIT-ASY-0118
Filmarray ME Panel, 30 Tests-RFIT-ASY-0118
20
RFIT-ASY-0144
Filmarray Pneumo Panel, 30 Tests-RFIT-ASY-0144
30
RFIT-ASY-0138
BioFire Joint Infection Panel, 30 Tests-RFIT-ASY-0138
30
Special handling for emergency orders of supplies: If the supplies are found to be defective and unsuitable for use with the Microbiology Laboratory equipment, or the Contractor has failed to comply with the requirements for routine supply delivery, the Contractor is required to deliver the supplies within 24 hours of receipt of a verbal order for emergency delivery. If either circumstance has occurred, the Contractor shall deliver to the Government site in the most expeditious manner possible without additional cost to the Government, the necessary consumables in sufficient quantity as required to allow operation of the Contractor s Core Laboratory equipment for one week (under normal Government test load volume). If additional requests for emergency supply delivery are required by the Government, they shall be honored by the Contractor until the arrival at the laboratory of the monthly standing order/routine supplies delivery.
Location
These reagent kits will be used in the Microbiology Laboratory located in the Pathology and Laboratory Medicine Service s San Antonio Laboratories of the STVHCS.
Period of Performance
Base +4 Option Years
Deliverables/Supplies: Reagent kits for the Bio Fire Film Array Instrumentation for use in the Microbiology Department.
Government Inherent Functions:
Contractor shall not perform inherently governmental functions. This includes, but is not limited to, determination of agency policy, determination of Federal program priorities for budget requests, direction and control of government employees, selection or non-selection of individuals for Federal Government employment including the interviewing of individuals for employment, approval of position descriptions and performance standards for Federal employees, approving any contractual documents, approval of Federal licensing actions and inspections, and/or determination of budget policy, guidance, and strategy.
General Duties, Requirements, and Expectations:
Be professionally competent to handle required duties.
Work with staff to ensure safety measures are in place and documented.
Services provided under the terms of this contract are required to be in compliance with the American Association of Blood Banks (AABB) and College of American Pathologists (CAP) accreditation policies and all applicable Federal, State and Government laws required by the Veteran s Healthcare System and VHA Handbook 1106.1.
Information Systems Officer, Information Protection:Â Â Â
The contractor will not have access to VA Desktop computers, nor will they have access to online resources belonging to the government while conducting services. If removal of equipment from the VA is required, any memory storage devices, such as hard drives, solid state drives and non-volatile memory units will remain in VA control and will not be removed from VA custody.Â
Privacy Officer:Â
The contractor will not have access to Patient Health Information (PHI), nor will they have the capability of accessing patient information during the services provided to the VA.
Records Manager:Â
There will be no federal records created, maintained, used or dispositioned with this contract;Â regardless of format [paper, electronic, etc.] or mode of transmission [e-mail, fax, etc.].
Files
| File | Type | Posted |
|---|---|---|
| 36C25724Q0258.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6550--FSS BPA - 36C25724A0023 - Biomerieux Consumables | Award Notice | |
| This notice | Pre-Solicitation | |
| Notice of Intent to Sole Source | Special Notice |
Similar open opportunities
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity