6515--TopCon Maestro2 OCT | Erie, Wilmington, Lebanon - RFQ
Closed Pre-Solicitation Posted
This opportunity was awarded. See the award notice from , or the latest solicitation from .
- Solicitation number
- 36C24424Q0852
- Agency
-
Veterans Integrated Service Network 4
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Place of performance
- Multi-site See Statement of Need, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs (VA) and Veterans Integrated Service Network 4 (VISN 4) have issued a Pre-solicitation Notice for a Request for Quote (RFQ) to acquire 3D OCT-1 Optical Coherence Tomography equipment. The objective is to expand the TeleEye care services to include higher-level screening for diabetic retinopathy, glaucoma, and macular degeneration. The equipment must meet or exceed technical requirements such as combination color fundus and OCT imaging, 12x9mm 3D wide OCT, panoramic fundus imaging, DICOM compliance, and full automation. The award will be for 10 Maestro 2 units, 10 two-position instrument tables, installation, calibration, on-site training, and shipping. The RFQ response is due on 09-26-2024 at 10:00 Eastern Time.
This procurement does not have a set-aside designation. The solicitation seeks brand name or equal equipment, with the Topcon Medical Maestros2 units as the basis of design. The total award value is not specified, but the quantities include 10 Maestro 2 units and 10 instrument tables to be delivered to VA medical facilities in Erie, Wilmington, Cape May, Vineland, and Lebanon.
Notice text
Statement of Need (SON)
BRAND NAME OR EQUAL
TeleEye Equipment Retinal Camera with OCT to MAESTRO2
Background: VISN 4 TeleEye is expanding to include new Mydriatic/Nonmydriatic retinal imaging cameras with OCT scan capability.
The Department of Veterans Affairs and VISN 4 have an immediate need for Topcon Medical Maestros2 units. Maestro2 is the basis of design, item number 102449804KUS brand name or equal. The objective is to expand the Tele Eye care services to include higher level screening for diabetic retinopathy, glaucoma, and macular degeneration, allowing providers to be more definitive in their initial assessment, improving accuracy and appropriateness of referrals for patients with identified pathology, reduce the number of referrals to eye clinics to obtain this baseline OCT scan, thereby preserving face to face access in the clinics and reducing related community care costs. This instrument allows for combined imaging of the retina and anterior segment and an OCT scan of the macula and optic nerve in one compact device.
Purpose of Project:
TeleEye to include higher level screening for diabetic retinopathy, glaucoma, and macular degeneration within VISN4.
Statement of Work:
Description of Work: The Vendor will deliver and install 3D OCT-1 Optical Coherence Tomography equipment to VISN 4 Veterans Affairs Medical Centers as outlined in the quote/contract. After set-up, the contractor must demonstrate that the System works as designed. Once this is completed and accepted by the COR, or designee, the contractor will provide training for clinical staff upon delivery and installation for the following facility:
Units
Location
Address
Attention
5
Erie VAMC
135 East 38th Street, Erie, PA 16504
CCM Holly Mukina and Dr. Tyler Mautino
1
Wilmington VAMC
1601 Kirkwood Hwy
Wilmington, DE 19805
Thomas Urso
1
Cape May CBOC
In the care of Wilmington
3801 Route 9 South, Suite 2, Rio Grande, NJ 08242-1915
TBD
1
Vineland CBOC
In the care of Wilmington
79 West Landis Avenue, Vineland, NJ 08360-8122
TBD
2
Lebanon VAMC
1700 South Lincoln Avenue
Lebanon, PA 17042-7529
TBD
Schedule of Deliverables:
Description of Tasks and Associated Deliverables and Salient Characteristics meets or exceeds:
Combination color fundus and oct images.
12x9mm 3D wide OCT with true color retinal photography
Pinpoint Registration to match OCT scans to the fundus reference image.
Ability to view images directly from the camera to see all OCT fields.
Widefield OCT
Panoramic fundus imaging
Picture angle 45 degrees +/- 5%
Scan range of 3-12 mm +/-5%
Scan speed of at least 50,000 scans per second - This high speed enables the acquisition of data sets within a few seconds
Fundus Resolution of at least 60 lines/mm or more for the center, 40 lines/mm or more for the middle( r/2), 25 lines/mm or more for the middle (r), and 5 lines/mm or more for center IR photography.
Anterior segment scanning
Color and IR photography for the anterior segment and fundus
Photographable diameter of pupil for fundus: 4.0 or more; small pupil diameter of 3.3mm or more; fundus tomogram diameter of pupil: 2.5mm or more
Fixation target: internal, peripheral, and external
DICOM compliant and able to integrate and archive data to the existing VISTA/CPRS Hospital Information System/Electronic Medical Record.
Fully automated OCT system that can capture high-resolution non mydriatic, true color fundus photography, and OCT with the single press of a button.
360 rotating intuitive touchscreens, 5 x7 - 7 x9 .
No Cost training by clinical application Specialist
Associated Deliverables- Brand name or equal
Item#
Item Name
Qty
102449804KUS
Maestro 2 3D OCT-1- w/Camera
10
25042-11-001
AIT-250 Two Position Instrument Table 24X36 Tabletop, Low Height 38", 450 Pound Capacity
10
-
Installation, Calibration, and On-Site Training
10
-
Shipping & Handling Included in Total Cost
10
Reports: Hood Report 1 for the structure/function analysis of glaucoma. This report will display the retinal nerve fiber layer (RNFL) thickness in nasal-superior-temporal-inferior-nasal (NSTIN) orientation so that the most vulnerable to nerve damage, the temporal region, is in the center, thus keeping RNFL bundles together.
Delivery and Packing, Inspection/Acceptance requirements, Warranty: The Systems are to be delivered to VISN 4 facilities listed in the Delivery Schedule. The contractor will be notified of the date the equipment will arrive at our facility and will schedule a date with the COR, or designee, for on-site set-up and installation of the System. After arrival, the System will be received by our Logistics/Warehouse staff, received in the services Equipment Inventory (EIL), barcoded, and safety inspected by Biomedical Engineering.
End of Statement of Work
Files
| File | Type | Posted |
|---|---|---|
| 36C24424Q0852.docx | DOCX document |
Notice history
| Notice | Type | Posted |
|---|---|---|
| 6515--TOPCON Maestro OCT 2 | Award Notice | |
| 6515--TopCon Maestro2 OCT | Erie, Wilmington, Lebanon - RFQ | Solicitation | |
| This notice | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 6525--SEP 2026 Equipment Only Consolidation | National Acquisition Center | No set-aside | |
| NX EQ Microscope Spine | VA Strategic Acquisition Center Frederick | No set-aside | |
| 6540--Carl Zeiss Visulas Combi YAG Green (VA-26-00065932) | Veterans Integrated Service Network 12 | No set-aside | |
| 6540--NX EQ eye lane (VA-27-00010051) | VA Strategic Acquisition Center Frederick | Service-Disabled Veteran-Owned Small Business | |
| Warm Springs Service Unit Optical Coherence Tomography with Angiography Installation, Calibration, and On-Site Training Services | Indian Health Service | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity