6515--NX EQ Irrigation Systems for Endoscopy (VA-26-00041944)

Closed Pre-Solicitation Posted

Solicitation number
36C10X26Q0064
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Nationwide, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Strategic Acquisition Center is conducting market research through this Sources Sought Notice to identify qualified suppliers of irrigation systems for endoscopy procedures. The VA seeks brand name or equal Steris ENDO STRATUS and ENDOGATOR Irrigation Pumps to be supplied on an agency-wide basis to VA medical centers and facilities throughout the United States. Prospective vendors must demonstrate capability to deliver products nationally and comply with six salient characteristics, including stable and adjustable flow rates, maximum pressure limits with automatic shutoff, footswitch activation capability, compatibility with common gastrointestinal endoscopy applications, single-use disposable tubing, and standard connectors. Respondents are required to submit technical literature demonstrating compliance with these specifications, annual service plan information if available, pricing inclusive of flat-rate shipping with any quantity discounts, and identification of any held federal contract vehicles. All interested offerors must be registered in SAM.gov with appropriate NAICS code certification prior to submission, and SDVOSB/VOSB offerors must be verified in the SBA database. The deadline for responses is March 5, 2026, at 5:00 PM Eastern Time, with submissions directed via email to Kyle Franks (kyle.franks@va.gov) and Felicia DeMita (Felicia.DeMita@va.gov).

This procurement carries no set-aside designation and represents a market research phase with no current incumbent identified. The VA intends to award a single Requirements Contract with Firm-Fixed Price orders under FAR 16.503, structured with one 12-month base period followed by four optional 12-month periods, contingent upon successful performance and continued need. The contract encompasses 31 Contract Line Items with estimated quantities of 100 units each across all five contract periods, including irrigation pumps, tubing sets compatible with various endoscope brands such as Olympus, Pentax, and Fujifilm, connectors, adapters, replacement parts, and the DEFENDO Y-OPSY Irrigator. The applicable NAICS code is 339113 (Surgical Appliance and Supplies Manufacturing) with a size standard of 800 employees. While specific budget information is not disclosed in this Sources Sought Notice, the estimated annual requirements for 31 line items at 100 units per item across five contract years indicate substantial procurement volume.

Notice text

Sources Sought Notice

Sources Sought Notice

Page 1 of 4

1.0 DESCRIPTION

THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs (VA) Strategic Acquisition Center (SAC) is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and the resources to meet the Veterans Health Administration s (VHA) Non-Expendable Equipment National Program requirement for Irrigation Systems for Endoscopy.

The SAC in conjunction with VHA is seeking a qualified source to supply brand name or equal Steris® ENDO STRATUS and ENDOGATOR Irrigation Pumps on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Irrigation Systems for Endoscopy to VA medical centers and facilities throughout the United States.

The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.

The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees.

The FAR Provision found at 52.204-7(b) requires that All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation. You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.

Submissions for this sources sought shall be submitted by email no later than March 05, 2025, 5:00 PM Eastern to all the following:

Kyle.franks@va.gov

Felicia.DeMita@va.gov

This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.

2.0 SCOPE OF WORK

Pumps are designed to deliver liquids (i.e., irrigate) to a cavity or other specific area of the body. These pumps typically consist of a central unit with a pumping (e.g., peristaltic) mechanism; a control (e.g., a valve, clamp, or manual or footswitch) to regulate the rate of the irrigation; and detachable (frequently disposable) tubing appropriate for irrigation of the intended body cavity or area. Irrigation pumps intended for particular equipment such as surgical, dental, and nasal irrigators are available; dedicated irrigation pumps intended for use with appropriate tubing coupled to irrigation catheters or cannulas are also available.

The following Contract Line Items are being considered:

Contract Line Items

Manufacturer

Part Number

Description

0001

Steris®

EGA500

ENDO STRATUS Irrigation Pump

0002

Steris®

EGASYST

ENDO STRATUS Irrigation Pump & CO2 Insufflator

0003

Steris®

EGA7030

ENDO STRATUS IV Style Cart

0004

Steris®

EGA7031

ENDO STRATUS Box Style Cart

0005

Steris®

100130

ENDOGATOR Irrigation Tubing for Use with EGA500 (24hr Use)

0006

Steris®

100609

ENDOGATOR Hybrid Tubing for OLYMPUS® 140/160/180/190 Series GI Endoscopes for Use with EGA500 (24hr Use)

0007

Steris®

4005644

ENDOGATOR Tubing for Use with EGP-100 US

0008

Steris®

4003170

TUBING HYBRID PENTAX EGA-500

0009

Steris®

4003178

TUBING HYBRID FUJI 700 EGA-500

0010

Steris®

100241

ENDOGATOR Single Patient Use Auxiliary Water Jet Connector for OLYMPUS® GI Endoscopes

0011

Steris®

100242

ENDOGATOR Single Patient Use Auxiliary Water Jet Connector for PENTAX® GI Endoscopes

0012

Steris®

100141

Adapter For Connecting ENDOGATOR Tubing to FUIFILM 530 Series GI Endoscopes (Single Patient Use)

0013

Steris®

100126

Backflow Valve (Single Patient Use)

0014

Steris®

4005629

ENDOGATOR Channel Adapter (Single Patient Use)

0015

Steris®

100303

DEFENDO Y-OPSY Irrigator for OLYMPUS® GI Endoscopes (Single Patient Use)

0016

Steris®

EGA7014

Power Cord (Replacement Part for EGA500)

0017

Steris®

EGA7010

Water Bottle Holder and Warmer Assembly (Replacement Part for EGA500)

0018

Steris®

EGA7016

Pump Head (Replacement Part for EGA500)

0019

Steris®

47049-942

Foot Pedal (Replacement Part for EGA500)

0020

Steris®

EGP100

ENDOGATOR Irrigation Pump

0021

Steris®

200270

Water Bottle Holder (Replacement Part for EGP100)

0022

Steris®

200230

ENDOGATOR Irrigation Tubing (Replacement Part for EGP100)

0023

Steris®

47049-492

Footswitch (Replacement Part for EGP100)

0024

Steris®

EGP012

Power Cord (Replacement Part for EGP100)

0025

Steris®

EGP014

Pump Head (Replacement Part for EGP100)

0026

Steris®

100115

ENDOGATOR Auxiliary Water Jet Connector for OLYMPUS GI Endoscopes (24hr Use)

0027

Steris®

100126

ENDOGATOR Backflow Valve (Single Use)

0028

Steris®

4005629

ENDOGATOR Channel Adapter (Single Use)

0029

Steris®

100241

ENDOGATOR Single-Use Auxiliary Water Jet Connector for OLYMPUS® GI Endoscopes (Single Use)

0030

Steris®

100242

ENDOGATOR Single-Use Auxiliary Water Jet Connector for PENTAX® GI Endoscopes (Single Use)

0031

Steris®

100303

DEFENDO Y-OPSY Biopsy Valve Irrigator for OLYMPUS® and FUJIFILM GI Endoscopes

The following Salient Characteristics (SCs) are being considered:

SC #

SALIENT CHARACTERISTICS

METHOD OF EVALUATION

SC 1

Must provide stable flow and fine adjustability to match the procedure (gentle mucosal rinse vs. higher-demand flushing) allowing user-selectable flow settings that do not surge when activated.

Literature Review

SC 2

Must include maximum pressure limits to prevent unsafe pressurization. Provides automatic shutoff and alarm on occlusion (kinked tubing, blocked channel, empty container) reducing risk of forcing fluid where it should not go and protecting the scope s working channels/accessories.

Literature Review

SC 3

Must support footswitch activation (preferred) or an equivalent hands-free control integrated with the endoscopy workflow allowing activation and without requiring the operator to leave the scope controls.

Literature Review

SC4

Must be compatible with common GI use cases, flushing, caps/valves, and where applicable water jet channels on endoscopes.

Literature Review

SC 5

Must use single-use/disposable tubing sets. External surfaces must be cleanable/disinfectable with common healthcare disinfectants and designed to resist fluid ingress.

Literature Review

SC 6

Must have standard connectors and tubbing sets designed for endoscopy irrigation maintaining compatibility with common use-cases: water jet channels, flushing caps, footswitch activation, and accessory valves.

Literature Review

For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics (SC) specified above.

The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.

Responses to this Sources Sought Notice shall include the following:

Full name and address of company.

SAM Unique Entity Identifier (UEI).

Business Size.

Manufacturer or Distributor:

If distributor, provide full name, business size and address of manufacturer.

If distributor, provide evidence that your firm is an authorized distributor for the manufacturer of the products proposed.

Country of Origin designation for all products proposed.

Ability to provide uninterrupted supply of products on a national scale.

Technical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met.

Does vendor offer an annual service plan, Yes or No?

If Yes:

What does the plan cover?

Does plan cover software updates only?

Does the plan cover parts repair or replacement only?

Does the plan cover both software and parts?

Vendor is requested to provide documentation that shows information on their service plan.

Is the service provided by the OEM or a subcontractor?

If distributor, provide full name, business size and address of manufacturer.

Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.

Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what level of quantity ordered should the Government expect tiered price reductions, if any.

NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.

Does your firm have any subcontracting opportunities for this equipment?

Identify any federal contracts vehicles held by your firm that provides this equipment.

Are there any further standards or criteria VA should consider in a procurement action for this equipment?

Are the Government s specifications unduly restrictive?

Any additional information the Government should know prior to issuing a solicitation.

Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.

Files

File Type Posted
36C10X26Q0064_Attachment_1.docx DOCX document
36C10X26Q0064.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
W065--Karl Storz Brand Name or Equal Equipment Lease Togus Vamc · NAICS 532490 Veterans Integrated Service Network 1 No set-aside
6515--Sterilizer Valley Coastal Bend South Texas Veterans Affairs VA Harlingen Healthcare Center Harlingen TX 78550 · NAICS 339112 Veterans Integrated Service Network 17 No set-aside
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide, United States · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business
6530--NX EQ Environmental Disinfection Systems Pulsed Xenon UV Light (VA-27-00012571) Nationwide · NAICS 334510 VA Strategic Acquisition Center Frederick No set-aside
W065--Questions and Responses-Notice of Intent (NOI)-Sole Source-Olympus America, Inc Gastrointestinal Endoscope Medical Equipment Lease Equipment Little Rock, Arkansas 72114, United States · NAICS 339112 Veterans Integrated Service Network 16 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors