This is a Sources Sought Notice issued by the Department of Veterans Affairs Strategic Acquisition Center (SAC) to conduct market research for irrigation systems used in endoscopy procedures across VA medical centers nationwide. The VA seeks qualified sources to supply brand name or equal Steris ENDO STRATUS and ENDOGATOR Irrigation Pumps on an agency-wide basis. The VA intends to award a single Requirements Contract with Firm-Fixed Price orders, with an anticipated period of performance of one 12-month base period plus four optional 12-month periods. The NAICS code is 339113 (Surgical Appliance and Supplies Manufacturing) with a size standard of 800 employees. Responses are due by March 5, 2026, at 5:00 PM Eastern Time and should be submitted via email to Kyle Franks (kyle.franks@va.gov) and Felicia DeMita (Felicia.DeMita@va.gov).

Respondents must provide their company information, SAM Unique Entity Identifier, business size, manufacturer or distributor details, country of origin for all products, and evidence of ability to supply products nationally. The notice specifies six salient characteristics that products must meet, including stable and adjustable flow rates, maximum pressure limits with automatic shutoff, footswitch activation capability, compatibility with common gastrointestinal endoscopy applications, single-use disposable tubing, and standard connectors. Vendors must submit technical literature demonstrating compliance with these characteristics, information on annual service plans if available, pricing inclusive of flat-rate shipping with any quantity discounts, and identification of any federal contract vehicles held. The notice lists 31 contract line items encompassing irrigation pumps (EGA500, EGASYST, EGA7030, EGA7031, EGP100), various tubing sets, connectors, adapters, and replacement parts. This notice is for planning purposes only and does not constitute a commitment to award a contract or pay for submitted information.

View the file

Other files

File Type Posted
36C10X26Q0064_Attachment_1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sources Sought Notice

SUBJECT*
NX EQ Irrigation Systems for Endoscopy (VA-26-00041944)

GENERAL INFORMATION

CONTRACTING OFFICE’S ZIP CODE*
21703
SOLICITATION NUMBER*
36C10X26Q0064
RESPONSE DATE/TIME/ZONE
03-05-2026 17:00 EASTERN TIME, NEW YORK, USA
ARCHIVE
30 DAYS AFTER THE RESPONSE DATE
RECOVERY ACT FUNDS
N

SET-ASIDE

PRODUCT SERVICE CODE*
6515
NAICS CODE*
339113
CONTRACTING OFFICE ADDRESS
U.S. Department of Veteran Affairs

OPAL | Strategic Acquisition Center

5202 Presidents Court | Suite 103 Frederick MD 21703

POINT OF CONTACT*

Contract Specialist Kyle Franks kyle.franks@va.gov

(202) 821-2334

PLACE OF PERFORMANCE

ADDRESS
Nationwide

POSTAL CODE

COUNTRY
US

ADDITIONAL INFORMATION

AGENCY’S URL
https://www.va.gov/opal/sac/index.asp
URL DESCRIPTION
VA | OALC | OPAL | SAC
AGENCY CONTACT’S EMAIL ADDRESS
kyle.franks@va.gov
EMAIL DESCRIPTION
kyle.franks@va.gov

DESCRIPTION

*= Required Field
Sources Sought Notice

Sources Sought Notice

1.0 DESCRIPTION

THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs’ (VA) Strategic Acquisition Center (SAC) is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and the resources to meet the Veterans Health Administration’s (VHA) Non-Expendable Equipment National Program requirement for Irrigation Systems for Endoscopy.

The SAC in conjunction with VHA is seeking a qualified source to supply brand name or equal Steris® ENDO STRATUS™ and ENDOGATOR™ Irrigation Pumps on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Irrigation Systems for Endoscopy to VA medical centers and facilities throughout the United States.

The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.

The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 – Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees.

The FAR Provision found at 52.204-7(b) requires that “All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation.” You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.

Submissions for this “sources sought” shall be submitted by email no later than March 05, 2025, 5:00 PM Eastern to all the following:

Kyle.franks@va.gov Felicia.DeMita@va.gov

This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.

2.0 SCOPE OF WORK

Pumps are designed to deliver liquids (i.e., irrigate) to a cavity or other specific area of the body. These pumps typically consist of a central unit with a pumping (e.g., peristaltic) mechanism; a control (e.g., a valve, clamp, or manual or footswitch) to regulate the rate of the irrigation; and detachable (frequently disposable) tubing appropriate for irrigation of the intended body cavity or area. Irrigation pumps intended for particular equipment such as surgical, dental, and nasal irrigators are available; dedicated irrigation pumps intended for use with appropriate tubing coupled to irrigation catheters or cannulas are also available.

The following Contract Line Items are being considered:

Contract Line Items
Manufacturer
Part Number
Description
0001
Steris®
EGA500
ENDO STRATUS™ Irrigation Pump
0002
Steris®
EGASYST
ENDO STRATUS™ Irrigation Pump & CO2 Insufflator
0003
Steris®
EGA7030
ENDO STRATUS™ IV Style Cart
0004
Steris®
EGA7031
ENDO STRATUS™ Box Style Cart
0005
Steris®
100130
ENDOGATOR™ Irrigation Tubing for Use with EGA500 (24hr Use)
0006
Steris®
100609
ENDOGATOR™ Hybrid Tubing for OLYMPUS® 140/160/180/190 Series GI Endoscopes for Use with EGA500 (24hr Use)
0007
Steris®
4005644
ENDOGATOR Tubing for Use with EGP-100 US
0008
Steris®
4003170
TUBING HYBRID PENTAX EGA-500
0009
Steris®
4003178
TUBING HYBRID FUJI 700 EGA-500
0010
Steris®
100241
ENDOGATOR™ Single Patient Use Auxiliary Water Jet Connector for OLYMPUS® GI Endoscopes
0011
Steris®
100242
ENDOGATOR™ Single Patient Use Auxiliary Water Jet Connector for PENTAX® GI Endoscopes
0012
Steris®
100141
Adapter For Connecting ENDOGATOR™ Tubing to FUIFILM™ 530 Series GI Endoscopes (Single Patient Use)
0013
Steris®
100126
Backflow Valve (Single Patient Use)
0014
Steris®
4005629
ENDOGATOR™ Channel Adapter (Single Patient Use)
0015
Steris®
100303
DEFENDO™ Y-OPSY™ Irrigator for OLYMPUS® GI Endoscopes (Single Patient Use)
0016
Steris®
EGA7014
Power Cord (Replacement Part for EGA500)
0017
Steris®
EGA7010
Water Bottle Holder and Warmer Assembly (Replacement Part for EGA500)
0018
Steris®
EGA7016
Pump Head (Replacement Part for EGA500)
0019
Steris®
47049-942
Foot Pedal (Replacement Part for EGA500)
0020
Steris®
EGP100
ENDOGATOR™ Irrigation Pump
0021
Steris®
200270
Water Bottle Holder (Replacement Part for EGP100)
0022
Steris®
200230
ENDOGATOR Irrigation Tubing (Replacement Part for EGP100)
0023
Steris®
47049-492
Footswitch (Replacement Part for EGP100)
0024
Steris®
EGP012
Power Cord (Replacement Part for EGP100)
0025
Steris®
EGP014
Pump Head (Replacement Part for EGP100)
0026
Steris®
100115
ENDOGATOR Auxiliary Water Jet Connector for OLYMPUS GI Endoscopes (24hr Use)
0027
Steris®
100126
ENDOGATOR Backflow Valve (Single Use)
0028
Steris®
4005629
ENDOGATOR™ Channel Adapter (Single Use)
0029
Steris®
100241
ENDOGATOR™ Single-Use Auxiliary Water Jet Connector for OLYMPUS® GI Endoscopes (Single Use)
0030
Steris®
100242
ENDOGATOR™ Single-Use Auxiliary Water Jet Connector for PENTAX® GI Endoscopes (Single Use)
0031
Steris®
100303
DEFENDO™ Y-OPSY™ Biopsy Valve Irrigator for OLYMPUS® and FUJIFILM™ GI Endoscopes

The following Salient Characteristics (SCs) are being considered:

SC #
SALIENT CHARACTERISTICS
METHOD OF EVALUATION
SC 1
Must provide stable flow and fine adjustability to match the procedure (gentle mucosal rinse vs. higher-demand flushing) allowing user-selectable flow settings that do not surge when activated.
Literature Review
SC 2
Must include maximum pressure limits to prevent unsafe pressurization. Provides automatic shutoff and alarm on occlusion (kinked tubing, blocked channel, empty container) reducing risk of forcing fluid where it should not go and protecting the scope’s working channels/accessories.
Literature Review
SC 3
Must support footswitch activation (preferred) or an equivalent hands-free control integrated with the endoscopy workflow allowing activation and without requiring the operator to leave the scope controls.
Literature Review
SC4
Must be compatible with common GI use cases, flushing, caps/valves, and where applicable water jet channels on endoscopes.
Literature Review
SC 5
Must use single-use/disposable tubing sets. External surfaces must be cleanable/disinfectable with common healthcare disinfectants and designed to resist fluid ingress.
Literature Review
SC 6
Must have standard connectors and tubbing sets designed for endoscopy irrigation maintaining compatibility with common use-cases: water jet channels, flushing caps, footswitch activation, and accessory valves.
Literature Review

For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics (SC) specified above.

The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.

Responses to this Sources Sought Notice shall include the following:

1. Full name and address of company.

1. SAM Unique Entity Identifier (UEI).

1. Business Size.

1. Manufacturer or Distributor:

3. If distributor, provide full name, business size and address of manufacturer.

3. If distributor, provide evidence that your firm is an authorized distributor for the manufacturer of the products proposed.

1. Country of Origin designation for all products proposed.

1. Ability to provide uninterrupted supply of products on a national scale.

1. Technical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met.

1. Does vendor offer an annual service plan, Yes or No?

7. If Yes:

0. What does the plan cover?

0. Does plan cover software updates only?

0. Does the plan cover parts repair or replacement only?

0. Does the plan cover both software and parts?

7. Vendor is requested to provide documentation that shows information on their service plan.

7. Is the service provided by the OEM or a subcontractor?

7. If distributor, provide full name, business size and address of manufacturer.

1. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.

1. Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what level of quantity ordered should the Government expect tiered price reductions, if any.

9. NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.

1. Does your firm have any subcontracting opportunities for this equipment?

1. Identify any federal contracts vehicles held by your firm that provides this equipment.

1. Are there any further standards or criteria VA should consider in a procurement action for this equipment?

1. Are the Government’s specifications unduly restrictive?

1. Any additional information the Government should know prior to issuing a solicitation.

Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.

See attached document: 36C10X26Q0064_Attachment_1.