36C10X26Q0064.docx
DOCX document 37 KB Posted
- Solicitation number
- 36C10X26Q0064
About this file
This is a Sources Sought Notice issued by the Department of Veterans Affairs Strategic Acquisition Center (SAC) to conduct market research for irrigation systems used in endoscopy procedures across VA medical centers nationwide. The VA seeks qualified sources to supply brand name or equal Steris ENDO STRATUS and ENDOGATOR Irrigation Pumps on an agency-wide basis. The VA intends to award a single Requirements Contract with Firm-Fixed Price orders, with an anticipated period of performance of one 12-month base period plus four optional 12-month periods. The NAICS code is 339113 (Surgical Appliance and Supplies Manufacturing) with a size standard of 800 employees. Responses are due by March 5, 2026, at 5:00 PM Eastern Time and should be submitted via email to Kyle Franks (kyle.franks@va.gov) and Felicia DeMita (Felicia.DeMita@va.gov).
Respondents must provide their company information, SAM Unique Entity Identifier, business size, manufacturer or distributor details, country of origin for all products, and evidence of ability to supply products nationally. The notice specifies six salient characteristics that products must meet, including stable and adjustable flow rates, maximum pressure limits with automatic shutoff, footswitch activation capability, compatibility with common gastrointestinal endoscopy applications, single-use disposable tubing, and standard connectors. Vendors must submit technical literature demonstrating compliance with these characteristics, information on annual service plans if available, pricing inclusive of flat-rate shipping with any quantity discounts, and identification of any federal contract vehicles held. The notice lists 31 contract line items encompassing irrigation pumps (EGA500, EGASYST, EGA7030, EGA7031, EGP100), various tubing sets, connectors, adapters, and replacement parts. This notice is for planning purposes only and does not constitute a commitment to award a contract or pay for submitted information.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C10X26Q0064_Attachment_1.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sources Sought Notice
| SUBJECT* |
| NX EQ Irrigation Systems for Endoscopy (VA-26-00041944) |
GENERAL INFORMATION
| CONTRACTING OFFICE’S ZIP CODE* |
| 21703 |
| SOLICITATION NUMBER* |
| 36C10X26Q0064 |
| RESPONSE DATE/TIME/ZONE |
| 03-05-2026 17:00 EASTERN TIME, NEW YORK, USA |
| ARCHIVE |
| 30 DAYS AFTER THE RESPONSE DATE |
| RECOVERY ACT FUNDS |
| N |
SET-ASIDE
| PRODUCT SERVICE CODE* |
| 6515 |
| NAICS CODE* |
| 339113 |
| CONTRACTING OFFICE ADDRESS |
| U.S. Department of Veteran Affairs |
OPAL | Strategic Acquisition Center
5202 Presidents Court | Suite 103 Frederick MD 21703
POINT OF CONTACT*
Contract Specialist Kyle Franks kyle.franks@va.gov
(202) 821-2334
PLACE OF PERFORMANCE
| ADDRESS |
| Nationwide |
POSTAL CODE
| COUNTRY |
| US |
ADDITIONAL INFORMATION
| AGENCY’S URL |
| https://www.va.gov/opal/sac/index.asp |
| URL DESCRIPTION |
| VA | OALC | OPAL | SAC |
| AGENCY CONTACT’S EMAIL ADDRESS |
| kyle.franks@va.gov |
| EMAIL DESCRIPTION |
| kyle.franks@va.gov |
DESCRIPTION
| *= Required Field |
| Sources Sought Notice |
Sources Sought Notice
1.0 DESCRIPTION
THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The Department of Veterans Affairs’ (VA) Strategic Acquisition Center (SAC) is issuing this Sources Sought Notice as a means of conducting market research to identify qualified sources with the capability and the resources to meet the Veterans Health Administration’s (VHA) Non-Expendable Equipment National Program requirement for Irrigation Systems for Endoscopy.
The SAC in conjunction with VHA is seeking a qualified source to supply brand name or equal Steris® ENDO STRATUS™ and ENDOGATOR™ Irrigation Pumps on an agency-wide basis. VA intends to award a single Requirements Contract with Firm-Fixed Price (FFP) orders IAW FAR 16.503, Requirements Contract to a supplier of this equipment. Vendors will be required to deliver Irrigation Systems for Endoscopy to VA medical centers and facilities throughout the United States.
The anticipated period of performance is for one 12-month base period with four 12-month option periods from the date of award. However, the Government's decision as to whether to continue with the contract, upon annual review, will be based upon successful performance during each previous year and continued need.
The associated North American Industrial Classification System (NAICS) code for this procurement is 339113 – Surgical Appliance and Supplies Manufacturing and the associated size standard is 800 employees.
The FAR Provision found at 52.204-7(b) requires that “All interested Offerors must be registered in SAM.gov prior to submitting an offer or quotation.” You may access the website at SAM.gov | Home. All offerors must be certified with the appropriate NAICS code on the SAM website. All SDVOSB/VOSB offerors must be verified in the SBA database at: https://veterans.certify.sba.gov/#search at the time of quote submission.
Submissions for this “sources sought” shall be submitted by email no later than March 05, 2025, 5:00 PM Eastern to all the following:
Kyle.franks@va.gov Felicia.DeMita@va.gov
This notice is for planning purposes only and does not constitute a commitment on the part of the Government to award a contract, nor does the Government intend to pay for any information submitted as a result of this notice. This Sources Sought Notice is part of a continuous process for obtaining the latest information on the commercial status of the industry with respect to their current and near-term abilities. The information provided herein is subject to change and in no way binds the Government to solicit for, or award, a competitive contract. It is emphasized that this is a notice solely for planning and informational purposes. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue a solicitation as a result of this notice. There is no solicitation available at this time.
2.0 SCOPE OF WORK
Pumps are designed to deliver liquids (i.e., irrigate) to a cavity or other specific area of the body. These pumps typically consist of a central unit with a pumping (e.g., peristaltic) mechanism; a control (e.g., a valve, clamp, or manual or footswitch) to regulate the rate of the irrigation; and detachable (frequently disposable) tubing appropriate for irrigation of the intended body cavity or area. Irrigation pumps intended for particular equipment such as surgical, dental, and nasal irrigators are available; dedicated irrigation pumps intended for use with appropriate tubing coupled to irrigation catheters or cannulas are also available.
The following Contract Line Items are being considered:
| Contract Line Items |
| Manufacturer |
| Part Number |
| Description |
| 0001 |
| Steris® |
| EGA500 |
| ENDO STRATUS™ Irrigation Pump |
| 0002 |
| Steris® |
| EGASYST |
| ENDO STRATUS™ Irrigation Pump & CO2 Insufflator |
| 0003 |
| Steris® |
| EGA7030 |
| ENDO STRATUS™ IV Style Cart |
| 0004 |
| Steris® |
| EGA7031 |
| ENDO STRATUS™ Box Style Cart |
| 0005 |
| Steris® |
| 100130 |
| ENDOGATOR™ Irrigation Tubing for Use with EGA500 (24hr Use) |
| 0006 |
| Steris® |
| 100609 |
| ENDOGATOR™ Hybrid Tubing for OLYMPUS® 140/160/180/190 Series GI Endoscopes for Use with EGA500 (24hr Use) |
| 0007 |
| Steris® |
| 4005644 |
| ENDOGATOR Tubing for Use with EGP-100 US |
| 0008 |
| Steris® |
| 4003170 |
| TUBING HYBRID PENTAX EGA-500 |
| 0009 |
| Steris® |
| 4003178 |
| TUBING HYBRID FUJI 700 EGA-500 |
| 0010 |
| Steris® |
| 100241 |
| ENDOGATOR™ Single Patient Use Auxiliary Water Jet Connector for OLYMPUS® GI Endoscopes |
| 0011 |
| Steris® |
| 100242 |
| ENDOGATOR™ Single Patient Use Auxiliary Water Jet Connector for PENTAX® GI Endoscopes |
| 0012 |
| Steris® |
| 100141 |
| Adapter For Connecting ENDOGATOR™ Tubing to FUIFILM™ 530 Series GI Endoscopes (Single Patient Use) |
| 0013 |
| Steris® |
| 100126 |
| Backflow Valve (Single Patient Use) |
| 0014 |
| Steris® |
| 4005629 |
| ENDOGATOR™ Channel Adapter (Single Patient Use) |
| 0015 |
| Steris® |
| 100303 |
| DEFENDO™ Y-OPSY™ Irrigator for OLYMPUS® GI Endoscopes (Single Patient Use) |
| 0016 |
| Steris® |
| EGA7014 |
| Power Cord (Replacement Part for EGA500) |
| 0017 |
| Steris® |
| EGA7010 |
| Water Bottle Holder and Warmer Assembly (Replacement Part for EGA500) |
| 0018 |
| Steris® |
| EGA7016 |
| Pump Head (Replacement Part for EGA500) |
| 0019 |
| Steris® |
| 47049-942 |
| Foot Pedal (Replacement Part for EGA500) |
| 0020 |
| Steris® |
| EGP100 |
| ENDOGATOR™ Irrigation Pump |
| 0021 |
| Steris® |
| 200270 |
| Water Bottle Holder (Replacement Part for EGP100) |
| 0022 |
| Steris® |
| 200230 |
| ENDOGATOR Irrigation Tubing (Replacement Part for EGP100) |
| 0023 |
| Steris® |
| 47049-492 |
| Footswitch (Replacement Part for EGP100) |
| 0024 |
| Steris® |
| EGP012 |
| Power Cord (Replacement Part for EGP100) |
| 0025 |
| Steris® |
| EGP014 |
| Pump Head (Replacement Part for EGP100) |
| 0026 |
| Steris® |
| 100115 |
| ENDOGATOR Auxiliary Water Jet Connector for OLYMPUS GI Endoscopes (24hr Use) |
| 0027 |
| Steris® |
| 100126 |
| ENDOGATOR Backflow Valve (Single Use) |
| 0028 |
| Steris® |
| 4005629 |
| ENDOGATOR™ Channel Adapter (Single Use) |
| 0029 |
| Steris® |
| 100241 |
| ENDOGATOR™ Single-Use Auxiliary Water Jet Connector for OLYMPUS® GI Endoscopes (Single Use) |
| 0030 |
| Steris® |
| 100242 |
| ENDOGATOR™ Single-Use Auxiliary Water Jet Connector for PENTAX® GI Endoscopes (Single Use) |
| 0031 |
| Steris® |
| 100303 |
| DEFENDO™ Y-OPSY™ Biopsy Valve Irrigator for OLYMPUS® and FUJIFILM™ GI Endoscopes |
The following Salient Characteristics (SCs) are being considered:
| SC # |
| SALIENT CHARACTERISTICS |
| METHOD OF EVALUATION |
| SC 1 |
| Must provide stable flow and fine adjustability to match the procedure (gentle mucosal rinse vs. higher-demand flushing) allowing user-selectable flow settings that do not surge when activated. |
| Literature Review |
| SC 2 |
| Must include maximum pressure limits to prevent unsafe pressurization. Provides automatic shutoff and alarm on occlusion (kinked tubing, blocked channel, empty container) reducing risk of forcing fluid where it should not go and protecting the scope’s working channels/accessories. |
| Literature Review |
| SC 3 |
| Must support footswitch activation (preferred) or an equivalent hands-free control integrated with the endoscopy workflow allowing activation and without requiring the operator to leave the scope controls. |
| Literature Review |
| SC4 |
| Must be compatible with common GI use cases, flushing, caps/valves, and where applicable water jet channels on endoscopes. |
| Literature Review |
| SC 5 |
| Must use single-use/disposable tubing sets. External surfaces must be cleanable/disinfectable with common healthcare disinfectants and designed to resist fluid ingress. |
| Literature Review |
| SC 6 |
| Must have standard connectors and tubbing sets designed for endoscopy irrigation maintaining compatibility with common use-cases: water jet channels, flushing caps, footswitch activation, and accessory valves. |
| Literature Review |
For each product (brand name and part number), the response must include descriptive literature demonstrating the product meets or exceeds the salient characteristics (SC) specified above.
The Government's intent is to include all ancillary items to ensure the equipment can function as designed by the OEM and as clinically required. Vendors are encouraged to provide any product solution or configuration so long as they meet the salient characteristics. Additionally, responses can include any additional product that may be beneficial. These items must be clearly identified by brand name and part number.
Responses to this Sources Sought Notice shall include the following:
1. Full name and address of company.
1. SAM Unique Entity Identifier (UEI).
1. Business Size.
1. Manufacturer or Distributor:
3. If distributor, provide full name, business size and address of manufacturer.
3. If distributor, provide evidence that your firm is an authorized distributor for the manufacturer of the products proposed.
1. Country of Origin designation for all products proposed.
1. Ability to provide uninterrupted supply of products on a national scale.
1. Technical Literature that clearly shows product(s) meets the identified salient characteristics and page numbers where each salient characteristic is met.
1. Does vendor offer an annual service plan, Yes or No?
7. If Yes:
0. What does the plan cover?
0. Does plan cover software updates only?
0. Does the plan cover parts repair or replacement only?
0. Does the plan cover both software and parts?
7. Vendor is requested to provide documentation that shows information on their service plan.
7. Is the service provided by the OEM or a subcontractor?
7. If distributor, provide full name, business size and address of manufacturer.
1. Any additional product solution or configuration that would be beneficial to the clinical functionality of the product line identified.
1. Item pricing information of products, inclusive of flat rate shipping. Include any quantity discounts, noting at what level of quantity ordered should the Government expect tiered price reductions, if any.
9. NOTE: In order for the Contracting Officer to determine whether a set-aside can be pursued, it is essential to provide pricing information. Without this information, the Contracting Officer will be unable to assess whether there is a reasonable expectation of receiving fair and reasonable pricing from socio-economic concerns.
1. Does your firm have any subcontracting opportunities for this equipment?
1. Identify any federal contracts vehicles held by your firm that provides this equipment.
1. Are there any further standards or criteria VA should consider in a procurement action for this equipment?
1. Are the Government’s specifications unduly restrictive?
1. Any additional information the Government should know prior to issuing a solicitation.
Although not required, vendors responding to this Sources Sought may also submit a Capabilities Statement.
See attached document: 36C10X26Q0064_Attachment_1.
Sources Sought Notice
File details come from the government source that posted it. Updated .