6515-- Medivator Endoscope Reprocessor
Open Pre-Solicitation Posted
- Solicitation number
- 36C26227Q0148
- Agency
-
Veterans Integrated Service Network 22
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 339112 Surgical and Medical Instrument Manufacturing
- Place of performance
- Department of Veterans' Affairs Jerry L. Pettis Veterans' Memorial Hospital Loma Linda CA 92357
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs, Veterans Integrated Service Network 22, is conducting market research through a request for information for a Medivator Endoscope Reprocessor, with responses due November 23, 2026 at 10:00 AM CST by email to ervin.hawkins@VA.gov. No set-aside is used. The RFI is not a solicitation and cannot form binding contracts, but pricing and capability information is encouraged for planning. It references pre-solicitation 36C26227Q0148, and formal solicitations may follow based on RFI responses.
The RFI seeks sources capable of providing a MEDIVATORS ADVANTAGE PLUS automated endoscope reprocessor manufactured by STERIS, Inc., for the Loma Linda, California Healthcare System. VA Network Contracting Office 22 in Long Beach, California is the contracting office, and performance is at Jerry L. Pettis Veterans' Memorial Hospital in Loma Linda, California 92357.
Responders must address twelve salient characteristics, including an asynchronous dual-basin configuration with independent operation, hands-free foot-pedal control, automated detergent washing using INTERCEPT or OEM-approved equivalent, individual channel-flow monitoring, compatibility with Olympus and Pentax endoscope hook-ups, high-level disinfection using RAPICIDE PA, automated leak testing, programmable alcohol flush, onboard data management, printing and data export including ConnectAssure services, and specified safety accessories. Equipment dimensions are 59 inches H x 45 inches W x 36 inches D, approximately 400 pounds, with 110V/air configuration and minimum water flow of 1.32 GPM.
Responses must answer 17 questions covering capabilities, business size under NAICS 339112 (1,000-employee threshold), manufacturer or distributor status, subcontracting limitations, COTS classification, Buy American Act conformity, FDA clearance status, federal contract holdings, and lead times.
Notice text
Please see attachment for full details of the sources sought.
Files
| File | Type | Posted |
|---|---|---|
| RFI AER Endoscope.docx | DOCX document | |
| 36C26227Q0148.docx | DOCX document |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| 6515--sterilization containers | Veterans Integrated Service Network 7 | No set-aside | |
| Offsite surgical reprocessing & sterilization | Veterans Integrated Service Network 22 | No set-aside | |
| J065--Relocate Advantage Plus Endoscope Reprocessing System Service | Veterans Integrated Service Network 23 | No set-aside | |
| 6515--FY27 - EER255509 - MultiLab Series II ROODRA Vascular System with DICOM (VA-27-00019885) | Veterans Integrated Service Network 17 | No set-aside | |
| 6515--Humidifier Heater Base Sources Sought | Veterans Integrated Service Network 12 | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity