6515-- Medivator Endoscope Reprocessor
Solicitation number
36C26227Q0148
Issued by

About this file

This is a Request for Information (RFI) issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 22 for market research and planning purposes only. The VA seeks information from qualified sources capable of providing a MEDIVATORS ADVANTAGE PLUS automated endoscope reprocessor (AER) manufactured by STERIS, Inc., for the VA Loma Linda, CA Healthcare System. The RFI is not a solicitation and responses cannot form binding contracts; however, pricing and capability information is encouraged for planning purposes. Responders must submit information via email to ervin.hawkins@VA.gov by Monday, November 23, 2026, at 10:00 AM CST.

The required equipment must meet 12 salient characteristics, including asynchronous dual-basin configuration with independent operation, hands-free foot-pedal control, automated detergent washing using INTERCEPT or OEM-approved equivalent, individual channel-flow monitoring, compatibility with Olympus and Pentax endoscope hook-ups, high-level disinfection using RAPICIDE PA, automated leak testing, programmable alcohol flush, onboard data management, printing and data export capabilities including ConnectAssure services, and specified safety accessories. The equipment specifications indicate dimensions of 59 inches H x 45 inches W x 36 inches D, approximately 400 pounds, requiring 110V/air configuration with minimum water flow of 1.32 GPM. Responders must address 17 specific questions covering capabilities statements, business size classifications under NAICS 339112 (1,000 employee threshold), manufacturer or distributor status, compliance with subcontracting limitations, COTS classification, Buy American Act conformity, FDA clearance status, federal contract holdings, and lead times. The RFI references a related pre-solicitation (Solicitation Number 36C26227Q0148) titled "6515--Medivator Endoscope Reprocessor," indicating that formal solicitations may follow based on RFI responses.

View the file

Other files

File Type Posted
36C26227Q0148.docx DOCX document

On GovTribe

Work with this file

  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

THIS REQUEST FOR INFORMATION (RFI) IS ISSUED SOLELY FOR INFORMATION AND PLANNING PURPOSES. THIS IS NOT A SOLICITATION.

SUBMISSION OF INFORMATION ABOUT PRICING, DELIVERY, THE MARKET, AND CAPABILITIES IS HIGHLY ENCOURAGED AND ALLOWED UNDER THIS RFI FOR PLANNING PURPOSES IN ACCORDANCE WITH (IAW) FAR 15.201(e).

DISCLAIMER

This RFI is issued solely for information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. IAW FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

RFI/SOURCES SOUGHT DESCRIPTION

This is NOT a solicitation announcement. This is an RFI Notice only. The purpose of this RFI Notice is to gain information about potential qualified sources and their size classification relative to NAICS 339112 (size standard of 1,000 Employees). Responses to this RFI will be used by the Government to make appropriate acquisition decisions. After review of the responses to this RFI Notice, further RFIs and/or solicitation or other announcements may be published.

The Department of Veterans Affairs (VA) is seeking information on and sources capable of providing a MEDIVATORS ADVANTAGE PLUS automated endoscope reprocessor (AER) for the VA Loma Linda, CA Healthcare System.

Brand-Name Product Information:

Manufacturer: STERIS, Inc.

Item #
Description/Part Number*
Qty
1
Adv Su Rap Pa 110V W/Air
1
2
Model 2-8-010 Assy, Hook-Up, Olympus
2
3
Model 2-8-030 Assy, Hookup, Pentax-0K
2
4
MODEL 2-8-511 ASSY, HOOK-UP, OLY
2
5
Model 2-8-611 Assy, Hook-Up, Oly
2
6
Model 2-8-811 Assy Hkup Oly-Echo+Lift
2
7
Kit, Intercept Uptake 1G
1
8
Adv,Printer System
1
9
Spill Kit Rap Pa
1
10
Adv,Active Vapor Mgt
1
11
Medivators Adv and Adv + Win10 Upgrade and Connectivity Set Up
1
12
Service visit to prepare one AER, Drying Cabinet or related device for data export to ConnectAssure
1
13
CAT Annual Subscription enables data export from one AER, Drying Cabinet or related device
1
14
ConnectAssure Data Services to Centralize Scope and User Data for Endo Equipment
1
15
Install, Advantage Plus Non-Business Day
1
16
2 Year Total Care Connect Advantage Plus
1
17
Project Design, Program Planning & Coordination Support Services Reprocessing GI
1

Salient Characteristics:

Must Have:

1. Asynchronous dual-basin configuration. Must provide two independently operated basins permitting separate endoscope loading and processing cycles in each basin.

2. Hands-free foot-pedal control. Must include foot-pedal operation to support instrument handling while reducing direct operator contact and potential cross-contamination.

3. Automated detergent washing. Must provide an automated detergent wash using INTERCEPT or an OEM-approved equivalent for compatible endoscopes. The supplied EER excludes duodenoscopes from its stated no-manual-brushing/flushing capability; endoscope and reprocessor IFUs govern all required manual steps.

4. Individual channel-flow monitoring. Must independently monitor connected endoscope channels, identify blockages, and verify proper fluid flow through each monitored channel.

5. Compatible endoscope hook-ups. Must support manufacturer-validated connections for compatible endoscopes. The quote lists two each of Olympus/Pentax hook-up assemblies 28010, 28030, 28511, 28611, and 28811; exact endoscope-model compatibility requires verification.

6. High-level disinfection process. Must provide a validated high-level disinfection process using RAPICIDE PA for compatible endoscopes. The technical reference states approximately five minutes at 86 degrees F (30 degrees C); the complete reprocessing-cycle time is not specified.

7. Automated leak testing. Must provide continuous automated leak testing during applicable endoscope processing, subject to the manufacturer's validated procedures.

8. Programmable alcohol flush. Must include an operator-programmable alcohol-flush function using manufacturer-authorized parameters.

9. Onboard data management. Must record, track, and permit retrieval of endoscope usage information and reprocessing-cycle logs through an onboard computerized system.

10. Printing and data export. Must support the quoted printer and manufacturer-supported data export / connectivity functions, including the ordered ConnectAssure-related services, subject to VA IT and Information Security approval.

11. Supplied safety/accessory configuration. Must include the quoted INTERCEPT uptake kit, RAPICIDE PA spill kit, and active vapor-management accessory as applicable to the delivered ADV1007 configuration.

12. Space and site-utility fit. Must fit the VA-designated installation location. For planning, the supplied technical reference lists 59 in. H x 45 in. W x 36 in. D, approximately 400 lb, and minimum water flow of 1.32 GPM; the quote specifies a 110V/air configuration. OEM installation requirements and clearances must be confirmed.

If your company is interested and capable of providing the required supplies/services, please provide the information indicated below. Response to this notice should include company name, address, point of contact, size of business pursuant to the following questions:

(1) Submit your capabilities statement illustrating how your organization can/cannot meet the list of draft salient characteristics described below. For instances where your company cannot meet the draft salient characteristic(s), please explain. For instances where your company can meet the draft salient characteristic(s), please show how your company meets/exceeds each requirement.

(2) Please review the list of draft salient characteristics and provide any additional feedback or suggestions. If none, please reply as N/A.

(3) Please indicate the size status and representations of your business, such as but not limited to: Service-Disabled Veteran-Owned Small Business (SDVOSB), Veteran-Owned Small Business (VOSB), HUBZone, Woman Owned Small Business (WOSB), Large Business, etc.

(4) Is your company considered small under the NAICS code identified in this RFI?

(5) Are you the manufacturer, authorized distributor, and/or can your company provide a solution to the required supplies/services described in the list of draft salient characteristics?

(6) If you are a large business, do you have any designated/authorized distributors? If so, please provide their company name, telephone, point of contact and size status (if available).

(7) If you’re a small business and you are an authorized distributor/reseller for the items identified above, do you alter, assemble, or modify the items requested in any way? If you do, state how and what is altered, assembled, or modified.

(8) Limitations on Subcontracting: How does your business ensure compliance with the limitations on subcontracting as outlined in 13 CFR § 125.6?

(9) Are the items you are identifying/providing considered Commercial of the Shelf (COTS) items as defined in FAR Part 2.101 under commercial items?

(10) Non-Manufacturer Rule: If applicable, can you confirm your business complies with the Non-Manufacturer rule? Specifically, does your company: Provide a product from a small business manufacturer or processor? Not exceed 500 employees? Primarily engage in the retail or wholesale trade and normally sell the type of item being supplied? Take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice?

(11) Please indicate whether your product conforms to the requirements of the Buy American Act? If you are unsure, please state the country of origin for each item.

(12) What is your lead time to deliver all items?

(13) Does your proposed equipment have FDA clearance (if needed)? Please specify what FDA clearance(s) have been obtained.

(14) Does your company have a Federal Supply Schedule (FSS) GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract? If so, please provide the contract number(s).

(15) If you are an FSS GSA/NAC/SAC/BPA/NASA SEWP or any other Federal Government contract holder, are all the items/solutions you are providing information about available on your schedule/contract? Please state if all or some items are available on the contract.

(16) General pricing of your products/solution is encouraged. Pricing will be used for the purpose of market research only. It will not be used to evaluate for any type of award.

(17) Please provide your SAM.gov Unique Entity ID number.

Responses to this notice shall be submitted via email to ervin.hawkins@VA.gov. Telephone responses will not be accepted. Responses must be received no later than Monday November 23, 2026 by 10:00 AM CST.

All responses to this RFI/Sources Sought will be used for planning purposes only. Responses to this RFI/Sources Sought Notice are not considered a request to be added to a prospective bidders list or to receive a copy of the solicitation. If further RFIs and/or a solicitation or other announcement is issued because of the information provided from this RFI, all interested parties must respond to the specific posting separately in accordance with the specifications of that announcement.

File details come from the government source that posted it. Updated .