6515--Cesium Cassette -

Closed Pre-Solicitation Posted

Solicitation number
36C26325Q0713
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Central Iowa VA Health Care Systems Des Moines, Iowa 50310, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs (VA) Central Iowa Health Care System is seeking qualified contractors to provide two Konica Minolta Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panels for its radiology department. These specialized medical imaging panels are designed as accessories for existing equipment, specifically compatible with a PXS710 High Frequency X-ray Machine and Konica Minolta AeroDr Battery Charger 2. The panels must meet several salient characteristics, including being wireless, lightweight (under 6 lbs), featuring a Cesium Digital Radiography panel, and having a minimum 16-bit image detector. Evaluation criteria will focus on technical acceptability, with emphasis on meeting or exceeding the specified characteristics for the 14x17 Momentum DR Cesium Detector. The sources sought notice is categorized under NAICS code 334517 for Irradiation Apparatus Manufacturing, and interested contractors must respond by April 29, 2025, at 11:00 AM Central Time.

No specific set-aside designation has been applied to this opportunity, though the notice indicates a small business size standard of 1,500 employees. The procurement involves two identical panels, which will enable more efficient foot x-rays for veterans with larger or swollen anatomies, potentially reducing radiation exposure and improving imaging quality. The panels come with a 3-year warranty for parts and labor, and no additional training or installation services are required. While no specific award value is mentioned, the equipment is intended to enhance medical imaging capabilities at the Central Iowa VA Healthcare System. Contractors responding to this sources sought notice should be prepared to provide detailed information about their capabilities, with the understanding that this is not a formal solicitation and does not guarantee future contract award.

Notice text

Page 2 of 2 Cesium Cassette Panel in support of Central Iowa VA Healthcare System This is a sources sought notice only and it is not a solicitation announcement. The purpose of this sources sought notice is to gain knowledge of qualified potential contractors and their socioeconomic size classification in accordance with NAICS code 334517 Irradiation Apparatus Manufacturing, size standard 1,500 employees for small business. Responses will be used by the Government to make appropriate acquisition decisions. After a review of the responses to this sources sought notice, a solicitation announcement may be posted. A response to this sources sought notice is not an adequate reply to a potentially forthcoming solicitation. The VA Central Iowa Health Care System located in Des Moines, Iowa is seeking qualified potential contractors to provide Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel for Central Iowa VA. Refer to the attached documents titled P09 Final Specifications Wireless 14x17 Cesium Cassette Panel for additional details and information. To respond to this sources sought notice, please complete the attached form titled Response Form to Sources Sought Notice and email the information requested to Marie Weathers, Contracting Specialist, at Michael.wicht@va.gov. The closing date and time of this sources sought notice is April 29 at 11:00 AM Central Time. This is not a solicitation and in no way obligates the Government to award any contract. Additionally, a response to this sources sought notice is not a request to be added to a prospective bidders list or to receive a copy of any forthcoming solicitation. Specification: Konica Minolta Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel 2237 Funding/ General Equipment Name: Konica Minolta Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel Description: The VA-CIHCS Imaging/Radiology/ Department has an immediate requirement for: two (2) Konica Minolta Premium Wireless 14x17 Cesium (CSI) Cassette Size TFT Panel This is an accessory/additional cassette for existing equipment in a larger size (14X17 vs 10X12). The cassettes must be able to interface (compatible with) with PXS710 High Frequency X-ray Machine, DELL Precision T3450 XE Acquire and Konica Minolta AeroDr Battery Charger 2. Only the Konica Minolta brand is compatible with the Konica Minolta battery charger per attached email from a vendor. This will accommodate foot x-rays for Veterans with larger, swollen or casted/booted anatomy. It enables us to take 1 exposure instead of 2 (less radiation) and provide better imaging quality. Must be 20/20 Imaging HD Momentum DR panel. Salient Characteristics (at least 5), The item must: be/ have/ do these things No tethered cables (wireless) Light weight imaging detector/cassette (less than 6 lbs) Cesium Digital Radiography (DR) panel Minimum of 16 bit image detector Full charge (empty to full) less than 15 min Must be compatible with Konica Minolta AeroDr Battery Charger 2 Evaluation Criteria Technically acceptable (meets or exceeds salient characteristics of 14X17 Momentum DR Cesium Detector) Small business consideration Cost Required Individual Line Items & Quantity of Items Item # Description/Part Number* Qty 1 14X17 DR Panel 2 (1 each) Cleaning Instructions for all equipment, supplies and accessories. 3-year warranty Optional Line Items Trade-In Items (include make, model and serial # of all items to be used as a trade-in) no trade in for this requirement. Product Specifications (CD, PDF or Word) available on Hospital Grade Wireless Digital DR Panel for Digital X-Ray 10x12 & 14x17, Cassette Sized true Flatpanel (2020imaging.net) Discount for Volume Purchase Not available for this purchase Expendable Supplies There are no expendable supplies for this equipment Maintenance and Full-Service Repair Contracts After 1 year Warranty Information - 3-year warranty (parts and labor) included in cost. In Service Training Training not required. Bio-Med Training Bio-med staff training not required. Installation and/or De-Installation Services (does this equipment require special electrical, gas, steam, oxygen, or network connectivity?) This equipment has no special install/de-install

Files

File Type Posted
Response Form to Sources Sought Notice 1.pdf PDF
36C26325Q0713.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
RFP-797-655A-03-0001-R6: 65VA X-Ray Equipment & Supplies NAICS 325992 Veterans Integrated Service Network 12 No set-aside
36C255-27-AP-0365 - CT Contrast Injector Maintenance Services Marion, Illinois 62959, United States · NAICS 811210 Veterans Integrated Service Network 15 No set-aside
6515--NX EQ Image Guided Surgical Navigation System (VA-26-00083972) Nationwide, United States · NAICS 334510 VA Strategic Acquisition Center Frederick Service-Disabled Veteran-Owned Small Business
J065--36C25927Q0027| Intent to Sole Source on FujiFilm Synapse Cardiology PACS Service and Licenses for Salt Lake City VA Medical Center NAICS 811210 Veterans Integrated Service Network 19 No set-aside
Managed Teleradiology Services - Phoenix Area IHS - SDVOSB Phoenix, Arizona 85004, United States · NAICS 621512 Indian Health Service Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity