6515--Brand Name or Equal to Transonic Systems Inc. - HD03 Hemodialysis Monitor. Unrestricted

Closed Pre-Solicitation Posted

This opportunity was awarded. See the award notice from , or the latest solicitation from .

Solicitation number
36C24425Q0840
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Wilkes-Barre VA Medical Center Attn Warehouse Wilkes-Barre, PA. 18711, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 4 is seeking to procure one Transonic Systems Inc. HD03 Hemodialysis Monitor or an equivalent product for the Wilkes-Barre VA Medical Center in Pennsylvania. This is a brand name or equal replacement requirement for an end-of-life hemodialysis monitor that must be compatible with existing Baxter hemodialysis machines currently used in the hemodialysis department. The monitor must be a stand-alone unit with rechargeable battery capability, H4FX sensors using transit-time burst ultrasound technology, and precise measurement capabilities for access flow (up to 4000ml/min), delivered flow (-2 to +2 L/min), and recirculation (0 to 100%). The requirement includes incidental services such as initial on-site staff training and delivery to the medical center warehouse between 8 AM and 4 PM, Monday through Friday, excluding federal holidays. The response deadline for this pre-solicitation notice is July 28, 2025, at 4 PM Eastern Time.

This procurement does not utilize any set-aside designations and is unrestricted competition. The current requirement is for a direct replacement of the same HD03 unit brand that is currently in use, indicating Transonic Systems Inc. may be considered the incumbent provider for this specific equipment. The solicitation is for a single unit quantity (one hemodialysis monitor) along with one Patient MEAS MOD and one H4FX sensor, representing a relatively small-scale procurement focused on maintaining continuity of care for veteran patients. No specific award value or budget range is provided in the pre-solicitation notice, and delivery is requested as soon as available and possible following contract award. The procurement falls under NAICS code 339112 (Surgical and Medical Instrument Manufacturing) and PSC 6515 (Medical and Surgical Instruments, Equipment, and Supplies).

Notice text

Statement of Need (SON)

Wilkes-Barre VA Medical Center 1111 East End Boulevard Wilkes-Barre, Pa. 18711

Brand Name or Equal to the Transonic HD03 Hemodialysis Monitor

Background: The Wilkes-Barre VA Medical Center (WBVAMC) located at 1111 East End Boulevard in Wilkes-Barre, Pa.18711 is a hospital that provides outpatient and inpatient veteran care services including primary care, mental health care, specialty care services, social programs/services, telehealth services, and a community living center nursing home. There are also 7 community-based outpatient clinics.

History of the Requirement: The Hemodialysis Department has a replacement requirement for one (1) Brand Name or Equal to the Transonic Systems Inc., HD03 hemodialysis monitor that has reached end-of-life (EOL) expectancy. The Brand Name or Equal to Transonic HD03 branded monitor is a replacement for the same branded unit currently used and compatible with the current hemodialysis department Baxter Hemodialysis Machines. The Wilkes-Barre VAMC Hemodialysis unit works tirelessly to provide the best possible care to our Veteran patients and having a seamless transition from the HD03 that needs to be replaced, to a new Brand Name or Equal Transonic HD03 Hemodialysis Monitor, will ensure that there isn t any down time as the unit, doctors, nurses, and technicians have expert knowledge in the uses of this monitor.

Summary of the Requirement: The Wilkes-Barre VAMC (station 693) has a new Brand Name or Equal to requirement for the purchase/replacement of one

(1) Transonic Hemodialysis HD03 monitor. The monitor will be used in the hemodialysis department. The unit would confirm the delivered flow, detect recirculation, and measure access flow quickly, optimizing hemodialysis treatment immediately for hemodialysis patients. It does not store patient information.

Detailed description of requirement: Other technologies may only detect certain types of stenosis at certain access points, whereas the HD03 monitor is unique in that it can accurately detect stenosis within any part of the access circuit. The HD03 provides on the spot vascular access, and access assessments to optimize treatment quickly and easily.

1 Transonic HD03 Hemodialysis Monitor Model number HD03 1 Patient MEAS MOD w/o PAT ID IN

1 H4FX SENSOR FOR THE HD03

Brand Name or Equal to Transonic HD03 Hemodialysis Monitor requirement request features/statements:

Compatible and currently used with Baxter hemodialysis machines. (This is a must).

Stand-alone unit with rechargeable battery for mobile patient to patient via IV pole portability

H4FX sensors that uses transit-time burst ultrasound technology.

Measurement access flow ranges up to 4000ml/min with accuracy the larger of +- 100 ml/min and +-15% of reading.

Measurement delivered flow range -2 to +2 L/min with accuracy +- 6% of the flow reading +- the zero offset.

Measurement recirculation range 0 to 100% with accuracy > 2% recirculation detected +- 3 % of displayed value.

Replaces the same HD03 unit, providing seamless integration for patient care.

Stand-alone device that measures delivered flow, recirculation, and vascular access flow during hemodialysis.

Touch screen at least 8.4

Rechargeable battery for mobile patient to patient via IV pole

Includes a pole mount kit.

H4FX Flow sensor

Incidental Services: Incidental services include but not be limited to initial training on using and maintaining the equipment. Initial on-site staff training is included in an HD03 purchase. The website Customer Portal has a full on- demand training Toolkit for ongoing educational support. The Toolkit contains training PowerPoints, videos, visual training aids, and competency checklists.

Installation Requirements: No installation is required.

Facility Access: N/A

Delivery Instructions:

Deliver equipment to Warehouse for processing: VA Medical Center

1111 East End Boulevard

Wilkes-Barre, Pa. 18711

Who is the delivery POC the Contractor should coordinate delivery with? POC is Mary Lynn Makar, BSN RN Nurse Manager Hemodialysis Unit, Phone 570-824-3521 ext. 27686 and Dennelle Ripka, Warehouse Supervisor, Phone 570-824-3521 ext.27178.

What are the hours for delivery, are there any challenges on site that might delay the person delivering the equipment to not be able to pull up to the medical center loading dock and drop off the equipment? Delivery should occur during normal business hours. All the equipment and accessories are requested to be delivered as soon as available and possible to the VAMC Wilkes-Barre located at 1111 East End Blvd in Wilkes-Barre, Pa. 18711 between the hours of 8am and 4pm Monday thru Friday excluding all Federal Holidays

Other special requirements or situations the Contractor should be aware of because they may affect their ability to deliver the equipment or perform the required installation or other services required. This may include vaccine requirements, TB testing results, mandatory training that needs to be completed i.e., safety, privacy, IT security etc. N/A

Language from VA Handbook 6500.6 and VA Directive 6550 as indicated in the respective Appendix A forms included in Force package.

VHA Supplemental Contract Requirements for Combatting COVID-19 language.

REPORTS/DELIVERABLES:

Delivery confirmation of equipment and commodities will be made through BioMed and the Logistics Department of the VA Wilkes Barre (693). This will include documentation of receipt and assignment of a facility based EE number for identification and tracking purposes.

Delivery confirmation of non-equipment/ commodities acquisitions is the responsibility of the receiving facility and/ or Service.

End of Statement of Need

Files

File Type Posted
36C24425Q0840.docx DOCX document

Notice history

Notice Type Posted
6515--Brand Name or Equal to Transonic Systems Inc. , HD03 Hemodialysis Monitor. Unrestricted Award Award Notice
6515--Brand Name or Equal to Transonic Systems Inc. - HD03 Hemodialysis Monitor. Unrestricted Latest solicitation Solicitation
This notice Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
W065--amia cycler lease dialysis NAICS 532490 Veterans Integrated Service Network 6 No set-aside
Q999--Peritoneal Dialysis Home Delivery Service Washington Dc Va Medical Center 50 Irving Street Nw, United States · NAICS 339113 Veterans Integrated Service Network 5 No set-aside
6550--VISN 4 Coagulation Testing Pittsburgh, Pennsylvania 15215, United States · NAICS 334516 Veterans Integrated Service Network 4 No set-aside
6515--Medtronic IPC Instruments Michael E. DeBakey VA Medical Center Houston, TX 77030, United States · NAICS 339112 Veterans Integrated Service Network 16 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors