6515--Brand-Name or Equal Amsco Steam Sterilizer RFI With Deinstallation & Installation

Closed Pre-Solicitation Posted

Solicitation number
36C24926Q0314
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Department of Veterans Affairs Lexington VA Medical Center Lexington, Kentucky 40502, United States

Notice details come from SAM.gov. Updated .

About this opportunity

Department of Veterans Affairs, Veterans Integrated Service Network 9, is conducting a sources sought notice for brand-name or equal Amsco steam sterilizers with deinstallation and installation services for Lexington VA Medical Center, with responses due July 21, 2026. This is an informational notice for planning purposes only and does not constitute a binding solicitation; no award will result from responses submitted.

The procurement requires three steam sterilizers—two larger units capable of holding a minimum of 15 trays and 375 pounds each, and one smaller unit capable of holding a minimum of 2 trays and 75 pounds. All units must be pre-vacuum sterilizers compliant with VHA Directive 1116(2), capable of sterilizing reusable medical devices in accordance with manufacturer instructions and facility requirements. Equipment must fit within current space constraints, utilize existing facility utilities, and include steam condensate sampling capability and steam filters. The two larger sterilizers must have external loading and transfer carriages. Vendors are required to visit the site to verify spatial and utility compatibility and must provide any stainless-steel paneling necessary to ensure compliance with VHA Directive 1116(2).

Turnkey services include delivery, unboxing, installation, configuration, validation, deinstallation of existing equipment, disposal, end-user training for 35 staff members, and removal of packaging and debris. Equipment delivery and installation are expected within 10–12 weeks of award. Sterile processing operations must remain operational throughout the installation period, with only one sterilizer out of service for extended periods as storage is unavailable. Place of performance is Lexington VA Medical Center, Lexington, Kentucky. Responses should be directed to Contract Specialist Kristie Collins at Kristie.Collins@va.gov.

Notice text

Department of Veterans Affairs

Lexington VA Medical Center

Sources Sought Notice

Brand Name or Equal Amsco Steam Sterilizer with Deinstallation and Installation

This Sources Sought Notice is for informational and planning purposes only and does not constitute a solicitation. Network Contracting Office 9 is seeking potential sources for Brand Name or Equal Amsco Steam Sterilizer. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offers submitted in response to this notice, and it shall not be implied that the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.

The Department of Veterans Affairs, Network Contracting Office 9, is seeking sources that can provide equipment that meets the following technical specifications:

Can be operated and maintained within VHA Directive 1116(2)

Can sterilize reusable medical devices in accordance with manufacturer s IFU and VHA Directive 1116(2).

Steam sterilizers must fit within current space requirements and utilize current facility utilities. Vendors must visit site to verify this.

The vendor must provide any stainless-steel paneling that is needed to ensure finished space is in compliance with VHA Directive 1116(2).

Steam sterilizers must be pre-vacuum.

Steam condensate samples must be able to be taken from the steam sterilizers.

Steam filters must be included with each sterilizer.

The 2 larger sterilizers must be able to hold a minimum of 15 trays and a minimum of 375 pounds.

The 1 smaller sterilizer must be able to hold a minimum of 2 trays and a minimum of 75 pounds.

Steam sterilizers must have a user manual.

The 2 larger sterilizers must have external loading/transfer carriages.

Sterilizer carriages must be height adjustable and have at least 3 shelves, at least 2 shelves must be height adjustable.

Sterilizers must be able to process trays 7.5 tall.

The 1 smaller sterilizer must have at least 2 inner racks.

All items must be packaged in a way that prevents damage during shipment.

Delivery must be coordinated with installation as storage will be unavailable.

All installation, configuration, and validation of equipment must be provided.

Vendor must be able to install units in a manner that does not cause a complete work stoppage for Sterile Processing.

Staff training provided on use and user level maintenance.

Items shall be shipped to:

Lexington VA Health Care System

Troy Bowling Campus

Attn: Rachel K Hall, 150BC

1101 Veterans Drive

Lexington, KY 40502

Items to be received are as follows brand name or equivalent:

Item #

Mfg

Part #

Description

QTY

0001

SR2322211011

Amsco 400 26X37.5X60 Prevacuum Single Hinge Recessed, 1- Wall Lh Steam 208V/240V

2

0002

AX070013081 GTIN: 00724995150624

26X37.5X60 Atlas Loading Car

4

0003

AX0660230830000013 GTIN: 00724995150631

Atlas Transfer Carriage 26X37.5X60" (Amsco 400)

4

0004

SE601852

Install - Medium Sterilizer

2

0005

SE6018521

Deinstallation - Medium Sterilizers

2

0006

SE6045100071

Disposal of Sterilizers and Generators

2

0007

SE601322

Install Loading Cart/Transfer Carriage

4

0008

SE61141

Steam Sample Pro Installation Package

2

0009

11037046

STERIS CLEAN FLOW PRO KIT

2

0010

SR0201210011 GTIN: 00724995209506

Amsco 400 20X20X38 Prevacuum Single Sliding Recessed Steam

1

0011

FV021011

Amsco 400 Series 20 X 20 X 38 Rack & Two Shelves, Single Door

1

0012

FV020012

GTIN: 00724995150518

Amsco® 400/Lab 250/Century 20X20X38" Intermediate Shelf

1

0013

SE011062

Install Small Sterilizer

1

0014

SE6018421

Deinstallation - Small Sterilizers

1

0015

SE6045100071

Disposal of Sterilizers and Generators

1

0016

SE61141

Steam Sample Pro Installation Package

1

0017

11057770

KIT,CLEAN FLOW & WTR COOL

1

Turnkey Services:

Proposal shall include all services required to (1) deliver, unbox, and set in place the new equipment; (2) uninstall, remove, and dispose of old equipment; (3) install, configure, and validate the new equipment; (4) provide end-user training; and (5) remove all packaging material and trash created by installation.

Period of Performance and Delivery Schedule:

Equipment delivery and installation should be scheduled with the SPS AO, SPS PSA, or SPS Chief within 10-12 weeks of award. Equipment shall be delivered in conjunction with the start of installation. Storage is unavailable.

Special Requirements:

Integrity of the sterile processing department must be maintained at all times: utilizing barriers, PPE, etc. to maintain compliance. Vendor will be responsible for ICRA barriers.

Equipment must fit within current space requirements and utilize current facility utilities. Vendors must visit site to verify this.

Sterile Processing must remain in operation. Only one sterilizer at a time can be taken out of service for long periods. Two of the three sterilizers can be taken out of service if less than 3 days.

Access panels must be maintained on both sides. Current sensors, switches, and shut offs must be maintained. Completed space must be compliant with Sterile Processing standards (e.g. no gaps/holes in wall, material can be cleaned/disinfected). Vendor is responsible for any additional stainless steel needed to fill gaps.

Vendor will have an education specialist on-site on the day of installation for any questions on the function, use, and maintenance of the equipment. Formal training and training materials will be provided for 35 staff.

All items will include a one-year warranty to cover all maintenance and malfunctions for the first year after installation.

The information above is intended to be descriptive, and not restrictive, to indicate the quality of equipment that will be satisfactory. It is the responsibility of the interested source to demonstrate to the Government that the interested source can provide equipment that fulfills the required specifications.

If you are interested, and can provide equipment that meets or exceeds the specifications listed, please provide the requested information below:

The anticipated North American Industry Classification System (NAICS) code is 339113. Mark if your firm is eligible for participation in one of the following small business programs. If so, please indicate the program:

[ ] yes [ ] no - Small Business (SB)

[ ] yes [ ] no - HUBZone

[ ] yes [ ] no - Small Business 8(a)

[ ] yes [ ] no - Small Disadvantaged Business (SDB)

[ ] yes [ ] no - Women-Owned (WO) Small Business

[ ] yes [ ] no - Service Disabled Veteran Owned Small Business (SDVOSB)

[ ] yes [ ] no - Veteran Owned Small Business (VOSB)

[ ] yes [ ] no - Large Business

[ ] yes [ ] no - Other (please specify)

[ ] yes [ ] no Are you the Original Equipment Manufacturer (OEM)?

[ ] yes [ ] no If not the OEM, are you an authorized distributor, and can produce a letter from the OEM?

[ ] yes [ ] no Is this product available on your GSA/FSS or other GWAC Contract?

If so, what is your contract number?_____________________

[ ] yes [ ] no Does your equipment conform to the Buy American Act and RFO 25.1? 25.1 Buy American - Supplies

What is the estimated Delivery Date After Receipt of Order (ARO)? _____________

Please include the following information:

Company Name:

POC:

UEI:

Address:

Email:

In addition to providing the information requested above, responding companies are encouraged to include any relevant information (specifications, cut sheets, brochures, capability statement, experience etc.) to confirm the company s ability to meet the requirements outlined in this request.

Responses to this notice are not offers and cannot be accepted by the U.S. Government to form a binding contract or agreement. This notice shall not be construed as a commitment by the Government to issue a solicitation, or ultimately award a contract, nor does it restrict the Government to a particular acquisition approach. The Government will in no way be bound to this information if any solicitation is issued.

Please respond to this RFI by July 21, 2026, at 5:00PM EST via email to Kristie.Collins@va.gov

Files

File Type Posted
36C24926Q0314.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
7125--Sterile Storage Cabinets VA Greater Los Angeles (GLA) Healthcare System Los Angeles CA 90073, United States · NAICS 339113 Veterans Integrated Service Network 22 No set-aside
DA10--Steris Software Connectivity Fresno CA 93703, United States · NAICS 541519 Veterans Integrated Service Network 21 No set-aside
J065--580-27-1-255-0018 Steris Base Contract Department Of Veterans Affairs Michael E Debakey Vamc Houston, Texas 77030, United States · NAICS 811210 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
J065--Copy of FY26: MBC Sternudrive LiteTM; Model MBC 709-Modular Department of Veterans Affairs VA Caribbean Healthcare System San Juan PR 00921 · NAICS 339112 Veterans Integrated Service Network 8 No set-aside
Z1DA--Sources Sought Notice/Market Research Project: Renovate SPS Phase 3 Central Virginia VA Healthcare System Cvhcs Richmond Virginia 23249 · NAICS 236220 Veterans Integrated Service Network 6 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors