459 MXS Rotary Air Compressor Replacement

Closed Solicitation Posted

Solicitation number
FA286026Q0025
Agency
Responses due
Set-aside
Total Small Business

Opportunity facts

Place of performance
JB Andrews, Maryland 20762, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Air Force Headquarters District Washington seeks supply, installation, and removal services for two 30-horsepower rotary screw air compressors and associated equipment at Joint Base Andrews, Maryland, with proposals due August 28, 2026 at 12:00 PM EST. This is a total small business set-aside with a 100% small business evaluation criterion.

Place of performance is Joint Base Andrews, Maryland (3640 Patrick Avenue, Hangar 11). The contractor must supply two Quincy QGD-30 or equivalent tank-mounted rotary screw compressors rated for 30 horsepower continuous duty, refrigerated air dryers, and oil-water separators; remove and dispose of two existing Ingersoll Rand 30 hp compressors; and perform all piping connections to the existing 1.5-inch aluminum compressed air header and electrical infrastructure. Equipment specifications require minimum air delivery of 125 CFM at 125 PSIG, 230/460V 3-Phase power, dimensions not exceeding 75" L x 40" W x 70" H, microprocessor-based controllers (Quincy Airlogic or equivalent), integrated air-aftercoolers, operation at approximately 68 dBA, and a minimum 5-year warranty on major components. Work must be completed within 30 calendar days of award during standard hours (0700–1530 Monday through Friday, excluding federal holidays). All contractor personnel must be U.S. citizens with prior project leadership experience and base security badging; contractors must submit security base access forms by August 19, 2026 and attend a mandatory site visit on August 25, 2026 at 10:00 AM EST. The NAICS code is 333912 (Air and Gas Compressor Manufacturing) and PSC is J043. Evaluation uses a Lowest Price Technically Acceptable approach. Wage Determination 2015-4281 (Revision 37) applies; service contract labor standards are incorporated. Solicitation Amendment 0002 was issued August 21, 2026, updating the Statement of Work and Salient Characteristics with no deadline extension.

Notice text

This Statement of Work (SOW) outlines the responsibilities of contractor chosen for the supply and installation of two each, air compressors, air dryer and oil water separator. It’s also for the removal and haul away of 2 each air compressor at 3640 Patrick Avenue, Joint Base Andrews. This project includes the replacement of the existing Ingersoll Rand 30 hp rotary screw compressors (2 each), refrigerated air dryer, and oil-water separator with two each of the same spec air compressor, air dryer and oil-water separator. This will include all the piping needed to connect the two air compressors, air dryer and oil-water separator to the existing piping to disperse the air through the building (Please see attached Statement of Work).

Files

File Type Posted
QA_27 Aug 2026 Final.pdf PDF
Solicitation Amendment FA286026Q00250002 SF 30.pdf PDF
SOW ch1.pdf PDF
Salient Characteristics ch1.pdf PDF
Compressor Room 5.jpg JPG image
Solicitation Amendment - FA286026Q00250001.pdf PDF
Solicitation Amendment FA286026Q00250001 SF 30.pdf PDF
Security Base Access Form ch1.xlsx XLSX spreadsheet
Salient Characteristics Sheet.pdf PDF
Compressor Room 3.jpg JPG image
Wage Determination 2015-4281 Revision No.37.txt TXT text file
Compressor Room 4.jpg JPG image
Compressor Room 1.jpg JPG image
Hangar 10 Compressor Statement of Work.pdf PDF
Compressor Room 2.jpg JPG image