This document package includes a solicitation for a federal construction contract opportunity and related drawings. The solicitation is for the removal and replacement of four bathrooms at the ZNY Air Route Traffic Control Center in Ronkonkoma, New York. Services required include demolishing existing bathroom facilities, installing new framing, plumbing, electrical, and finishes. Drawings provide details on demolition plans, bathroom layouts, and construction details. The opportunity is set aside for small businesses, with a North American Industry Classification System code of 238220. The solicitation number is 697DCK-21-R-00259. Interested contractors must register in the System for Award Management and submit PDF proposals to the specified email address by the response deadline. A mandatory site visit is scheduled.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

NY

AS

06/25/2020 1706242

ZNY-1706242-D001

C O

N S

T R

U

IO

ENGINEERING SERVICES

SURV./WEATHER

ARTCC

REFURBISH ADMIN WING BASEMENT BATHROOMS

NEW YORK CENTERRONKONKOMA

PROJECT ENGINEER MGR: ENGINEERING - CENTER B

z n y -1

-d

.d g

DRAWING PRODUCED ON AEA RO MICROSTATION SYSTEM

ATO - TECHNICAL OPERATIONS EASTERN SERVICE AREA

DEMO PLAN - BASEMENT

DT#18909

E D

M

IS

F

PROJECT NORTH

CONTROL WING

WING

ADMINISTRATION

SUPPORT

BUILDING

AREA

WORKING

NOT TO SCALE

U'P'UA

KEY PLAN

AREAWAY ELEC SERVICE

INCINERATOR

FREIGHT

ELEVATOR

BLDG MAINT.

CORRIDOR

EWC

SCALE: 1/4" = 1'-0"

TRENCH

EXISTING

ALL MATERIALS SHALL BE BROUGHT IN AND OUT THROUGH AREA WAY.

APPROVED IN ADVANCE BY THE RE/COR.

BETWEEN 11 PM AND 5AM AND BE COORDINATED WITH THE FACILITY AND

OR ANY WORK IN THE AIR TRAFFIC CONTROL ROOM SHALL BE DONE

WHICH DISTURBS AIR TRAFFIC OPERATIONS IN THE ACTIVE CONTROL ROOM

APPROVED BY THE RE/COR. IN ADDITION, ANY NOISE PRODUCING WORK

SHALL BE SCHEDULED IN ADVANCE, COORDINATED WITH THE FACILITY AND

OPERATIONS SHALL BE DONE AFTER 4:30PM AND BEFORE 7AM. SUCH WORK

ANCHOR OR CORE DRILLING, WHERE SUCH WORK AFFECT AIR TRAFFIC

DEMOLITION AND CONSTRUCTION NOISE WITHIN THE FACILITY, SUCH AS

BATHROOMS HAS A SHOWER. COMPETELY DEMO SHOWER STALL.

CEILINGS, FLOORS, WATER CLOSERTS, SINKS, ETC. ONE OF THE UNISEX

COMPLETELY DEMO BOTH UNISEX BATHROOMS. REMOVE WALLS,

REMOVE ALL FIRE ALARM DEVICES IN BOTH BATHROOMS.

IN MECHANICAL, ELECTRICAL AND FIRE PROTECTION DRAWINGS.

COORDINATE THE EXTENT OF DEMOLITION WITH WORK SHOWN

AS INDICATED.

COORDINATE THE EXTENT OF DEMOLITION WITH NEW CONSTRUCTION

F.

E.

D.

C.

B.

A.

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

ADJUST FIRE SPRINKLERS AS REQUIRED FOR NEW CEILING INSTALLATION.

IS COMPLETED.

REMOVE PA SPEAKER AND SAVE FOR REINSTALLATION AFTER CONSTRUCTION

COMPLETELY DEMO SHOWER, SHOWER WALLS, AND SOFFIT.

AND DIFFUSERS WILL ALSO BE REPLACED.

REMOVE DOMESTIC WATER PIPING TO NEAREST VALVES. ALL REGISTRARS

REMOVAL ALL PIPING BEHIND WALLS, BOTH WATER AND SANITARY.

AND REINSTALLATION.

COORDINTE AND HIRE SIMPLEX, THE FIRE ALARM VENDOR, FOR REMOVAL

REMOVE FIRE ALRM STROBE LIGHTS AND KEEP FOR REINSTALLATION.

WILL REMOVE ALL SWITCHES AND RECEPTABLES AND REPLACE WITH NEW.

DEMO ALL LIGHTS AND WIRING BACK TO JUNCTION BOXES. CONTRACTOR

OF THE CONTRACTOR TO RESTORE THE AREA IN QUESTION.

ONCE DEMO WORK HAS STARTED IT IS SOLELY THE RESPONSIBILITY

DOCUMENTED IN WRITING TO THE R.E. PRIOR ANY DEMO WORK COMMENCING.

ANY AREA THAT IS DAMAGED PRIOR TO DEMO WORK WILL NEED TO BE

SHALL BE RESTORED TO IT"S ORIGINAL CONDITION PRIOR TO DEMO.

ALL ADJACENT FINISHES, CEILINGS ETC REMOVED DURING DEMO

DAMAGED FRAMING PRESENT AFTER REMOVAL OF DRYWALL.

FOR TILE DEMO, WALLS ARE DRY WALL. REPLACE ANY RUSTED OR

BEFORE START OF CONSTRUCTION.

INSTALL A 2 X 4 DUST PARTITINO WITH PLASTIC AROUND BATHROOMS

DEMOLITION NOTES:

GENERAL NOTES:

4' 8'04'

BASEMENT DEMOLITION PLAN

D001

-d

/2

:1

:3

P lo tt e d b

V

-C

A

G -E

B

H

8 7 6 5 4 3 2 1

12345678

REVDRAWING NO

DATE JCN

APPROVED BY

ISSUED BY

CHECKED

DRAWN

DESIGNED

SUBMITTED BY

REVIEWED BY

FEDERAL AVIATION ADMINISTRATION

DEPARTMENT OF TRANSPORTATION

REV

DATE

APPROVED

DESCRIPTION JCN

REDLINE

APVD

zny-1706242-d001

2020-11-10T15:12:24-0500

DAVID WINKLER

2020-10-29T13:47:28-0400

Alisa Nicole Da Silva

ZNY-1706242-G001

COVER SHEET AND DRAWING INDEX

-g

DRAWING TITLEDRAWING NUMBER

DRAWING INDEX

T OF TRANSPO

T A

IC

OF

STATES

IT

TM

EN

AVIA

I

L

TRAT

SI

NI

ZNY-1706242-A002

ZNY-1706242-A001

ZNY-1706242-D001

ZNY-1706242-G001

RONKONKOMA, NEW YORK

DETAILS

ADMIN BASEMENT BATHROOM INSTALL

DEMO PLAN - BASEMENT

COVER SHEET & DRAWING INDEX

-g lo tt e zny-1706242-g001

2020-11-10T15:09:41-0500

DAVID WINKLER

2020-10-29T13:48:40-0400

Alisa Nicole Da Silva

ZNY-1706242-A001

-a

AREAWAY ELEC SERVICE

INCINERATOR

FREIGHT

ELEVATOR

BLDG MAINT.

CORRIDOR

EWC

23.

22.

21.

20.

19.

18.

17.

16.

15.

14.

13.

12.

11.

F.

E.

D.

C.

B.

A.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

GENERAL NOTES:

INSTALLATION NOTES:

INSTALLATION NOTES (CONTINUED):

TRENCH

EXISTING

LOADING DOCK WILL ONLY BE USED FROM 10AM TO 2PM.

LOADING DOCK WILL BE USED TO REMOVE MATERIALS.

APPROVED IN ADVANCE BY THE RE/COR.

AND 5AM AND BE COORDINATED WITH THE FACILITY AND

TRAFFIC CONTROL ROOM SHALL BE DONE BETWEEN 11 PM

IN THE ACTIVE CONTROL ROOM OR ANY WORK IN THE AIR

PRODUCING WORK WHICH DISTURBS AIR TRAFFIC OPERATIONS

APPROVED BY THE RE/COR. IN ADDITION, ANY NOISE

IN ADVANCE, COORDINATED WITH THE FACILITY AND

4:30PM AND BEFORE 7AM. SUCH WORK SHALL BE SCHEDULED

AFFECT AIR TRAFFIC OPERATIONS SHALL BE DONE AFTER

SUCH AS ANCHOR OR CORE DRILLING, WHERE SUCH WORK

DEMOLITION AND CONSTRUCTION NOISE WITHIN THE FACILITY,

COMPETELY DEMO SHOWER STALL.

ONE OF THE UNISEX BATHROOMS HAS A SHOWER.

WALLS, CEILINGS, FLOORS, WATER CLOSERTS, SINKS, ETC.

COMPLETELY DEMO BOTH UNISEX BATHROOMS. REMOVE

REMOVE ALL FIRE ALARM DEVICES IN BOTH BATHROOMS.

DRAWINGS.

SHOWN IN MECHANICAL, ELECTRICAL AND FIRE PROTECTION

COORDINATE THE EXTENT OF DEMOLITION WITH WORK

CONSTRUCTION AS INDICATED.

COORDINATE THE EXTENT OF DEMOLITION WITH NEW

USE 36" SQUARE BASE FOR SHOWER.

INSTALL NEW CONCRETE BOARD WITH TILES FOR SHOWER STALL.

FOR COUNTERTOP. SEE DETAIL FOR INSTALLATION OF COUNTERTOP.

WOMAN'S BATHROOM ACROSS FROM TOILET. COTR WILL SELECT COLOR

INSTALL A NEW 4" QUARTZ COUNTERTOP AND MIRROR ON WALL IN

BASE TO BE INSTALLED ON FLOOR.

CEMENT BOARD. NEW SBWA-36-3F 36" X 36" CEMENT SHOWER

METAL STUDS. INSTALL NEW FRAMING ON NEW 5/8" X 4' X 8'

SHOWER FRAMING WILL NEED TO BE FRAMED OUT WITH NEW

ANY OTHER FIRE PROTECTION EQUPIMENT ON THE CEILING.

REMOVE AND REPLACE FIRE SPRINKLERS, HORN/STROBES AND

VALVES UNDER DROP CEILING. CELING TO BE REPLACED TOO.

REMOVE AND REPLACE WATER AND SEWER TO NEAREST VALVE.

TO USE ON SITE.

INSTALL GFI OUTLET UNDER SINK. COR TO DESIGNATE CIRCUIT

STANDARDS (UFAS) REQUIREMENTS.

INSTALL PER CURRENT UNIFORM FEDERAL ACCESSIBILITY

TOILET REQUIREMENTS. GRAD BARS ARE TO BE 42" IN LENGTH.

INSTALL TWO (2) STAINLESS STEEL GRAB-BARS PER HANDICAPED

FRAMELESS MIRROR ABOVE SINK IN BOTH BATHROOMS.

INSTALL AND PROPERLY FASTEN A NEW B-292 1836 18" X 36"

DEMO AND INSTALL NEW FLOOR TILE IN BOTH BATHROOMS.

WALL TILE SHALL BE INSTALLED FROM FLOOR TO CEILING.

RUSTED OR DAMAGED FRAMING SHALL BE REPLACED.

INSTALL DRY WALL TO FRAMING AND OVERLAY WITH TILE.

BATHROOM".

THE DOORS. BOTH SHOULD BE SAY "UNISEX

PROVIDE AND INSTALL NEW BATHROOM SIGNS ON

LOCKSETS AND CLOSURES.

PAINT EXISTING DOORS AND ADD NEW SET OF

MATCH EXISTING TYPE.

INSTALL NEW HVAC REGISTERS AND DIFFUSERS.

EXISTING LIGHTING CIRCUITS FOR NEW LIGHTING.

FMC POWER SENTRY BATTERY PACKS. USE

DOWN LIGHTS WILL BE ISNTALL WITH PS1055CP

COTR WILL DETERMINE LOCATIONS. 4 OF THE

THE MEN'S AND 6 IN THE WOMEN'S BATHROOM.

LED DOWN LIGHTS WITH LO6AR LSS TRIM. 4 IN

INSTALL 10 LITHONIA LDN6 35/15 MVOLT GZ10 HSG

IN BOTH BATHROOMS.

TILES WITH PRELUDE 15/16" SUSPENSION SYSTEM

ARMSTRONG DUN ANGLED TEGULAR 15/16 2" X 2"

INSTALL NEW CEILING GRID WITH NEW TILES

TO RECEIVE NEW TILE.

WHERE TILE MEETS WALL. PROPERLY PREP FLOOR

BE SELECTED BY COTR. PROVIDE FLOOR BULLNOSE

6" X 6" GLAZED PROCELAIN TILE. COLOR WILL

TILE FOR WALLS SHALL BE DAL TILE SANDALO

BE SUBMITTED FOR APPROVAL.

OF ACCENT TILE AT 5' HEIGHT. LAYOUT SHALL

ACCESSORIES AS REQUIRED. PROVIDE A BORDER

TILE OUTSIDE CORNERS AND OTHER TILE

BE SELECTED BY COTR. PROVIDE BULL NOTE

12" X 12" GLAZED PORCELAIN TILE. COLOR WILL

TILE FOR WALLS SHALL BE DAL TILE SANDALO

TO WORK WITH 120 VOLT POWER.

NECESSARY FOR FAUCETS AND SOAP DISPENSER

BATHROOMS. SUPPLY ALL ACCESSORIES

ON THE NEW SINKS IN THE MEN'S AND WOMEN'S

WITH THE PLUG IN MODEL 060918A TRANSFORMER

AND 2 DELTA MODEL #: DESD-550 SOAP DISPENSER

INSTALL 2 DELTA MODEL 590TPA2120-PI FAUCETS

EXISTING CIRCUIT TO USE FOR NEW RECETACLES.

FAUCET AND SOAP DISPENSER. COTR WILL DESIGNATE

NEW RECEPTACLESUNDER NEW SINKS FOR ELECTRIC

WHERE EXISTING ONE ARE LOCATED. INSTALL TWO

INSTALL NEW RECEPTACLES IN BOTH BATHROOMS

DETERMINED BY COTR.

ABOVE CEILING FOR POWER. CIRCUITS WILL BE

PAPER TOWEL DISPENSER. INSTALL RECEPTACLES

AC EXTERNAL ADAPTER (6V) FOR EACH

TO BE DETERMINED BY COTR. INSTALL 3974-57

RECEPTACLE. ONE IN EACH RESTROOM. LOCATION

DISPENSER EQUIPPED WITH LED LIGHT/WASTE

CONVERTIBLE AUTOMATIC, UNIVERSAL ROLL TOWEL

INSTALL TWO BOBRICK B-3974 RECESSED

SEE SPECIFICATIONS.

INSTALL BATHROOM AND SHOWER ACCESSORIES.

EACH TOILET.

HYBRID 1.28 GPF FLUSHOMETER K-7531-CP FOR

AUTOMATIC TOILET FLUSH VALVES TRIPOINT EXPOSED

RESTROOMS WITH HEAVY DUTY CARRIERS AND

TOILETS WITH K-4731-CA-0 TOILET SEATS IN BOTH

INSTALL A NEW WALL MOUNTED KOHLER K-4325-SS-0

APPROVED EQUAL WITH HEAVY DUTY CARRIER.

SINK KOHLER MORNINGSIDE K-12638-R OR

STALL A WALL-MOUNT WHEELCHAIR BATHROOM

4' 8'04'

A001 lo tt e zny-1706242-a001

2020-11-10T15:15:39-0500

DAVID WINKLER

2020-10-29T13:44:38-0400

Alisa Nicole Da Silva

ZNY-1706242-A002

DETAILS

11" (MAX)

2'-0" (MAX)

FACE OF FINISH WALL

2' 0"

CASED EDGE

IN MASTIC

MIRROR SET

SOAP DISPENSER

3/4 " PLYWOOD (FRT)

SUPPORT FRAME

SIDE WALL WELDED TO

CONCEALED @ EACH

STL. TUBE POSTS

3" x 2" x 1/4"

SINK DETAIL2

A002 NOT TO SCALE

A002 SCALE: 3" = 1'-0"

CEILING-EXPOSED "TEE" SYSTEM

TYPICAL SUSPENDED ACOUSTICAL TILE

RUNNER AT 2'-0" OC

1"x1" NOMINAL CROSS

4'-0" OC

1"x1 1/2" MAIN RUNNER TEE

#8 HANGER WIRES @ 4'-0" OC

TO STRUCTURE ABOVE

WIRE HANGERS ATTACHED

ANGLE CONTINUOUS

1"x1" NOMINAL WALL

APPROVED EQUAL

TUBE SUPPORT FRAME OR

3" x 2" x 1/4" GALV STEEL

MAT'L SPLASH

3/4" QUARTZ SURFACE

FINISH

SCHEDULED

MAT'L TOP AND APRON

3/4" QUARTZ SURFACE

SHOWER BASE DETAIL

S S

*CONSULT LOCAL BUILDING CODES

SOLID PHENOLIC FOLDING SHOWER SEAT

18"

36"

3" (75)

1 1/2" (40)

6" (150)

1/2" (15)1 1/2" (40)

2 1/2" (65)

1/2" (15)

11 7/8" (300mm)

5 15/16" (150mm)

2 1/4" (55mm)

DIA. BOLT CIRCLE

1 1/8" (30mm)

2 1/4" (55mm) m

15" (455mm)

3 1/16" (75mm)

RECOMMENDED

430 TO 510MM

*17" TO 20"

(400mm)

15-13/16"

5 1/2" (140mm)

1 3/8" (35mm)

FINISH FACE OF FACE

BRACKET

GUIDE

FACE OF FLOOR

FINISH

WITH SPRING

BASEPLATE

BRACKET

FLANGES (2)

MOUNTING

NOT FURNISHED BY BOBRICK

BUILDING CODES

TO COMPLY WITH LOCAL

CONCEALED WALL BACKING

(SEE REFLECTED CEILING PLANS)

ACOUSTICAL TILE CEILING

2x2 LAY-IN PANEL

OR TO L2 1/2"x2 1/2"x1/4"

CONNECT TO STRUCTURE ABOVE

12'-0" OC IN EACH DIRECTION.

2" OF CROSS RUNNER SPACED

TO MAIN RUNNER WITHIN

DIRECTIONS, 90 PART. CONNECT

#12 WIRES SPLAYED IN 4

:4 lo tt e zny-1706242-a002

2020-11-10T15:14:06-0500

DAVID WINKLER

2020-10-29T13:45:53-0400

Alisa Nicole Da Silva

File details come from the government source that posted it. Updated .